The Effect of Bone Density Measured by Cone Beam Computed Tomography and Implant Dimensions on the Stability of Dental Implants
...Show More Authors

Abstract: The aim of this study was to evaluate the effect of bone density value in Hounsfield unit derived from cone beam computed tomography (CBCT), and implant dimensions in relation to implant stability parameters namely the resonance frequency analysis and the insertion torque (IT) value. It included 24 patients who received 42 dental implants (DI). The bone density of the planned implant site was preoperatively measured using cone beam computed tomography. The implant stability was measured using Osstell implant stability quotient (ISQ). The ISQ values were recorded immediately postoperatively and after 16 weeks. The IT value was categorized as 35 N/cm or > 35 N/cm. The mean (standard deviation) primary stability was 79.58 (5.27) ISQ, which was significantly higher than the secondary stability 74.31 (6.34) ISQ (P < 0.0001). There was a significant moderate positive correlation of bone density with primary stability (r = 0.4, P = 0.0099) and no correlation with secondary stability (r = 0.003, P = 0.9867). The bone density of DI with 35 N/cm IT was significantly lower than with > 35 N/cm IT (P = 0.0390). Better stability was recorded with wider implants. Whereas the length of the DI showed a nonsignificant correlation with primary and secondary stability (P = 0.7633 and 0.4670, respectively). The DI dimensions showed a nonsignificant correlation with the IT. Cone beam computed tomography may be considered as a reliable method to assess bone density and predict the implant stability. The diameter of DI affected the implant stability favorably, whereas DI length showed no effect.

Scopus Clarivate Crossref
View Publication
Publication Date
Tue Mar 30 2021
Journal Name
Journal Of Economics And Administrative Sciences
Employing the indicators of stereotypes and the dimensions of organizational clarity and their role in achieving the planned organizational behavior Analytical study on a sample of workers in some departments of the Faculties of Engineering, University of
...Show More Authors

The current research examines the employment of indicators of stereotypes and the dimensions of organizational clarification to achieve planned organizational behaviour on a sample of employees in a number of departments of the Faculties of Engineering, University of Kufa, for a sample of (122) teaching staff. This research proposes the use of positive indicators of stereotypes for both the organization and employees and their awareness of what they want to obtain and what should be done for both parties and the removal of organizational clarity represented by the functional dimension that explores to what degree the employee's understanding of the internal strategy of the organization and the strategic dimension that searches fo

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Sun Jun 12 2011
Journal Name
Baghdad Science Journal
Calculating the density of electronic charge for hydrogen atom and ions like atom
...Show More Authors

The radial wave function R(r) and the radial distribution function P(r) as a function of (r), for the Hydrogen atom was calculated for several atomic state (1s,2s,2p,3s,3p,3d) The results were compared with Hydrogen like atom(He+,Li+2,Be+3).

View Publication Preview PDF
Crossref
Publication Date
Sun May 02 2021
Journal Name
Journal Of Accounting And Financial Studies ( Jafs )
The extent of adopting the dimensions of the Blue Ocean Strategy and its impact in the market share: بحث استطلاعي في شركة الحمراء للتأمين
...Show More Authors

With the increase in competition between insurance companies in addition to the increasing numbers in the number of insurance companies, whose number decreased to (32) private companies until the end of the year (2020). The blue ocean at the level and its effects on increasing the market share. Therefore, the two researchers tested the hypothesis and the research concluded that there is a relationship A .Also the researcher put some recommendations the most prominent is that the invention is considered one of the successful strategies an d the company has to encourage the employees according to inventive thoughts

View Publication Preview PDF
Publication Date
Sun Mar 01 2020
Journal Name
Iraqi Journal Of Physics
THE DIFFERENCE IN THE CHARGE DENSITY DISTRIBUTION OF 90Zr and 92Mo NUCLEI FROM ELASTIC ELECTRON SCATTERING
...Show More Authors

The calculation. of the nuclear. charge. density. distributions. ρ(r) and root. mean. square. radius.( RMS ) by elastic. electron. scattering. of medium. mass. nuclei. such. as (90Zr, 92Mo) based. on the model. of the modified. shell. and the use of the probability. of occupation. on the surface. orbits. of level 2p, 2s eroding. shells. and 1g gaining. shells. The occupation probabilities of these states differ noticeably from the predictions of the SSM. We have found. an improvement. in the determination. of ground. charge. density. and this improvement. allow. more precise. identification. of (CDD) between. (92Mo- 90Zr) to illustrate the influence of the extra

... Show More
View Publication Preview PDF
Crossref
Publication Date
Mon Feb 01 2021
Journal Name
Iop Conference Series: Materials Science And Engineering
On modelling and adaptive control of a linear smart beam model interacting with fluid
...Show More Authors
Abstract<p>This paper deals with modelling and control of Euler-Bernoulli smart beam interacting with a fluid medium. Several distributed piezo-patches (actuators and/or sensors) are bonded on the surface of the target beam. To model the vibrating beam properly, the effect of the piezo-patches and the hydrodynamic loads should be taken into account carefully. The partial differential equation PDE for the target oscillating beam is derived considering the piezo-actuators as input controls. Fluid forces are decomposed into two components: 1) hydrodynamic forces due to the beam oscillations, and 2) external (disturbance) hydrodynamic loads independent of beam motion. Then the PDE is discretized usi</p> ... Show More
View Publication
Crossref
Publication Date
Sat Feb 01 2025
Journal Name
Journal Of Dentistry
Dynamic navigation-guided robotic placement of zygomatic implants
...Show More Authors

Objectives: To assess the feasibility and accuracy of a new prototype robotic implant system for the placement of zygomatic implants in edentulous maxillary models. Methods: The study was carried out on eight plastic models. Cone beam computed tomographs were captured for each model to plan the positions of zygomatic implants. The hand-eye calibration technique was used to register the dynamic navigation system to the robotic spaces. A total of 16 zygomatic implants were placed, equally distributed between the anterior and the posterior parts of the zygoma. The placement of the implants (ZYGAN®, Southern Implants) was carried out using an active six-jointed robotic arm (UR3e, Universal Robots) guided by the dynamic navigation coordinate tr

... Show More
View Publication Preview PDF
Scopus (9)
Crossref (10)
Scopus Crossref
Publication Date
Mon Oct 12 2026
Journal Name
Journal Of Baghdad College Of Dentistry
Comparative study of retention of fiber-reinforced post at middle and cervical one thirds of root canal cemented by polycarboxylate and zinc phosphate cements measured at different storage times
...Show More Authors

Background: The purpose of this study was to compare regional bond strength at middle and cervical thirds of the root canal among glass fiber-reinforced composite (FRC) endodontic posts cemented with different cements, using the push-out test to compare the performance (retention) of two types of luting cements; polycarboxylate cement and Zinc phosphate cement used to cement translucent fiber post and to compare the result of the push-out test at different storage times;1 week ,1month and 2 months. Materials and methods: Ninety caries-free, recently extracted single-rooted human teeth with straight root canals was used in this study, The root canals were endodontically instrumented at a working length of 0.5 mm from the apex by m

... Show More
View Publication Preview PDF
Publication Date
Sat Jan 01 2022
Journal Name
3rd International Scientific Conference Of Alkafeel University (iscku 2021)
Exposure and etching time effects on the fission track density in CR-39 detectors using teeth samples
...Show More Authors

View Publication
Scopus (1)
Crossref (1)
Scopus Crossref
Publication Date
Fri Mar 15 2019
Journal Name
Journal Of Baghdad College Of Dentistry
The impact of depression status on dental caries severity among internally displaced people in Baghdad/Iraq
...Show More Authors

Background: changing in lifestyle like displacing place could cause depression which is a common mental disorder that change general health that affect dental caries incidence and severity. The aims of this study were to assess the relation of depression status on prevalence and severity of dental caries among internally displaced people. Material and Method: The sample include 121 internally displaced people aged from 13-17 years. Method for depression measuring is by using Children Depression Inventory (CDI2) questionnaire. Dental caries is measured by using caries experience (DMFs) and caries severity D1-4. Result: the mean value for decayed and missing surfaces were higher in high depression grade as compering with low and medium dep

... Show More
View Publication
Scopus (3)
Crossref (1)
Scopus Crossref
Publication Date
Mon Oct 12 2026
Journal Name
Journal Of Baghdad College Of Dentistry
Effect of different palatal vault shapes and woven glass fiber reinforcement on dimensional stability of high impact acrylic denture base [part II]
...Show More Authors

Background: Change in palatal vault shape and Reinforcement of high impact acrylic denture base resin may in turn affect the dimensional accuracy of acrylic resin and affecting the fitness of the denture. The aim of study is to evaluate the effect of fiber reinforcement for high-impact acrylic resin denture base with different palatal vault shapes on linear dimensional change and effect of palatal vault shapes on linear dimensional changes of non-reinforced and fiber reinforced high impact denture base acrylic resin Material and method: Three different palatal vault shapes were prepared on standard casts using CNC (computer numerical control) machine. 60 samples of heat polymerized high impact acrylic resin maxillary denture base were fabri

... Show More
View Publication Preview PDF