Preferred Language
Articles
/
YBYDTocBVTCNdQwCFkOb
The Effect of Bone Density Measured by Cone Beam Computed Tomography and Implant Dimensions on the Stability of Dental Implants
...Show More Authors

Abstract: The aim of this study was to evaluate the effect of bone density value in Hounsfield unit derived from cone beam computed tomography (CBCT), and implant dimensions in relation to implant stability parameters namely the resonance frequency analysis and the insertion torque (IT) value. It included 24 patients who received 42 dental implants (DI). The bone density of the planned implant site was preoperatively measured using cone beam computed tomography. The implant stability was measured using Osstell implant stability quotient (ISQ). The ISQ values were recorded immediately postoperatively and after 16 weeks. The IT value was categorized as 35 N/cm or > 35 N/cm. The mean (standard deviation) primary stability was 79.58 (5.27) ISQ, which was significantly higher than the secondary stability 74.31 (6.34) ISQ (P < 0.0001). There was a significant moderate positive correlation of bone density with primary stability (r = 0.4, P = 0.0099) and no correlation with secondary stability (r = 0.003, P = 0.9867). The bone density of DI with 35 N/cm IT was significantly lower than with > 35 N/cm IT (P = 0.0390). Better stability was recorded with wider implants. Whereas the length of the DI showed a nonsignificant correlation with primary and secondary stability (P = 0.7633 and 0.4670, respectively). The DI dimensions showed a nonsignificant correlation with the IT. Cone beam computed tomography may be considered as a reliable method to assess bone density and predict the implant stability. The diameter of DI affected the implant stability favorably, whereas DI length showed no effect.

Scopus Clarivate Crossref
View Publication
Publication Date
Mon May 01 2023
Journal Name
Journal Of Engineering
The Effect of Type of Fiber in Density and Splitting Tensile Strength of SIFCON
...Show More Authors

SIFCON is characterized as a construction material of high ductility and very high strength. It is suitable for concrete structures used for special applications. However, the density of SIFCON is much higher than that of Fiber Reinforced Concrete (FRC) due to the need for a large amount of high-density steel fibers. This work examines the split tensile behavior of modified weight slurry infiltrated fiber concrete utilizing a mixture of two types of fibers, steel fiber, and polyolefin fiber. For the investigation, 30 cylinders and 15 cubes were poured. The used volume fraction (V.F) is (6 %) and the use of five series once as each type separately and once a hybrid in proportions of 2/3 polyolefin with 1/3 steel fiber and

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Wed Aug 10 2022
Journal Name
International Journal Of Biomaterials
Use of Eggshells as Bone Grafts around Commercially Pure Titanium Implant Screws Coated with Nano Calcium Sulfate
...Show More Authors

Background. Implant insertion in regions with poor bone quantity, such as the posterior maxilla, is potentially associated with an increased rate of implant failure. Calcium sulfate can be used as the coating material for commercially pure titanium (CpTi) and as the bone graft material around implants when bound to eggshell powder to enhance the bone quality and quantity of bone defect regions. This study performed a torque removal test to evaluate the effectiveness of eggshell powder as a bone substitute for filling bone defects around CpTi-coated implants coated with nanocrystalline calcium sulfate. Materials and Methods. Eighty screw implant designs were used in the tibiae of 20 white New Zealand rabbits. A total of uncoated 20 s

... Show More
View Publication
Crossref (14)
Crossref
Publication Date
Tue Dec 01 2009
Journal Name
Iraqi Journal Of Physics
Fractional Free Volume Dependence of Neutron-Irradiated Polystyrene (PS) Measured by Positron Method
...Show More Authors

The fractional free volume (Fh) in polystyrene (PS) as a function of neutron -irradiation dose has been measured, using positron annihilation lifetime (PAL) method. The results show that Fh values decreased with increasing n-irradiation dose up to a total dose of 501.03× 10-2 Gy.
A percentage reduction of 2.14 in Fh values is noticed after the initial n-dose corresponding to a percentage reduction in the free volume equal to 42.14/Gy.
The total n-dose induces a percentage reduction of 7.26, corresponding to a percentage reduction of 1.45/Gy. These results indicate that cross -linking is the predominant process induced by n-irradiation.
The results suggest that n-irradiation induces structure changes in PS, causing cross-linking

... Show More
View Publication Preview PDF
Publication Date
Wed Sep 15 2021
Journal Name
Journal Of Baghdad College Of Dentistry
The effect of contact time between alginate impression material and type III dental stone on the surface properties of stone casts
...Show More Authors

Background: Alginate impression material is the irreversible hydrocolloid material that is widely used in dentistry. The contact time between alginate and gypsum cast could have a detrimental effect on the properties of the gypsum cast. The objective of this study is to evaluate the impact of various contact time intervals of Alginate impressions & type III dental stone on surface properties of stone cast. Materials and Methods: Time intervals tested were 1hour, 6 hours and 9 hours. Surface properties of stone cast evaluated were surface detail reproduction, hardness and roughness. Surface detail reproduction was determined using cylindrical brass test block in accordance with ISO 1563. Surface roughness was measured by profilometer

... Show More
View Publication Preview PDF
Scopus Crossref
Publication Date
Wed Dec 15 2010
Journal Name
Iraqi Journal Of Laser
Evaluation the Effect of 805 nm Wavelength Diode Laser on Repair of Mandibular Bone Repair and Skin Incisions in Rabbits
...Show More Authors

The long healing time of bone after tooth extraction in order to construct artificial teeth is uncomfortable to the patient because of aesthetic or masticatory problems in addition to the daily visit to dental clinic. The objective of this study was to evaluate the effect of 805 nm diode laser with long time intervals on repair of bone and skin incisions in rabbits through biochemical, radiological and histological findings. Eighteen New-Zealand rabbits were undergone surgical operations to make a cavity in the bone of the lower jaw, the rabbits were divided into two groups:- Group A (control group) containing nine rabbits. Group B (lased group) containing nine rabbits in which two cavities were done, one on the right side and the other

... Show More
View Publication Preview PDF
Publication Date
Wed Mar 10 2021
Journal Name
Baghdad Science Journal
The effect of temperature and density of different host spam in efficiency and performance life of the intruder
...Show More Authors

Studied competence spam to malicious moth figs at temperatures and Kagafat host different results showed that female intruder, despite their ability to shell larvae host and when densities of different, but it is able to lay eggs at a temperature of 14 + or -1 and finally urged the efficiency spam to malicious affected heavily host and that the greater the intensity of the host spam increased efficiency and its performance life

View Publication Preview PDF
Publication Date
Sun Jan 01 2023
Journal Name
Journal Of Medicine And Life
Effect of commercially pure titanium implant coated with calcium carbonate and nanohydroxyapatite mixture on osseointegration
...Show More Authors

In this research, rabbit femurs were implanted with CP Ti screws coated with a combination of CaCO3 and nanohydroxyapatite, and the effect on osseointegration was assessed using histological and histomorphometric examination at 2 and 6 weeks. CaCO3 and nanohydroxyapatite were combined with the EPD to coat the surfaces of the CP Ti screws. The femurs of five male rabbits were implanted with coated and uncoated implant screws. Healing time was divided into two groups (2 and 6 weeks). After 2 and 6 weeks of implantation, the histological examination revealed an increase in the growth of bone cells for coated screws, and the histomorphometric analysis revealed an increase in the percentage of ne

... Show More
View Publication
Scopus (7)
Crossref (8)
Scopus Crossref
Publication Date
Sun Nov 01 2020
Journal Name
The International Journal Of Oral &amp; Maxillofacial Implants
Early Failure Rate and Associated Risk Factors for Dental Implants Placed With and Without Maxillary Sinus Augmentation: A Retrospective Study
...Show More Authors

View Publication
Scopus (24)
Crossref (21)
Scopus Clarivate Crossref
Publication Date
Sat Jan 01 2022
Journal Name
Proceeding Of The 1st International Conference On Advanced Research In Pure And Applied Science (icarpas2021): Third Annual Conference Of Al-muthanna University/college Of Science
Effect of etching time on the track density of fission fragments human teeth samples with Lexan detector
...Show More Authors

View Publication
Scopus (1)
Scopus Crossref
Publication Date
Sun Apr 07 2013
Journal Name
Journal Of Educational And Psychological Researches
The effect of relaxation music in reducing symptoms of dental anxiety
...Show More Authors

Many behavioral researchers pointed out the importance of relaxation techniques in the treatment of different psychological disorders where find  the importance of these techniques in reducing anxiety and stress and the resulted of behaviors and habits, with the development of these techniques are being used to gain public health, whether mental health or physical or mentality, and one of these techniques is music therapy that reduces tension and anxiety and operates a state of relaxation, which is used in the treatment of  patients of dental clinic.                        

Re

... Show More
View Publication Preview PDF