COVID-19 was declared a pandemic by the World Health Organization in March 2020, and the SARS-CoV-2 virus continues to be a global concern with new variants. Our research focused on the relationship between COVID-19 and air pollution, and we included findings from recently published research. In summary, there is a direct relationship between air pollution and COVID-19 infection and fatality rates. This relationship was evident after many parts of the world declared lockdowns. Research to understand the relationship between infection rates and air pollutants identified indirect factors that contributed to the spread of infection. In this article, we explore studies on air pollutants, the use of face masks, weather conditions, short- and long-term exposure, infection and mortality, and modeling of the pandemic.
The present paper aims at investigating the linguistic image portrayed by UNICEF reports on the Iraqi child from a critical discourse analysis perspective during Covid19 pandemic (2020). The paper attempts to fill a gap in research literature concerning the linguistic construction of the Iraqi child by the UNICEF reports during the critical health crisis of Covid19. Van Leeuwen’s (2008) approach of social actor representation has been adopted for this purpose. From Van Leeuwen’s approach, the category of determination (single determination and overdetermination) has been selected to be the main analytical tool for its high compatibility with the set of objectives put forward to figure out how such a globally effective and
... Show MoreA time series analysis can help to observe the behavior of the system and specify the system faults. In addition, it also helps to explain the various energy flows in the system and further aid in reducing the thermodynamic losses. The intelligent supervisory LabVIEW software can monitor the incoming data from the system by using Arduino microcontroller and calculates the important parameters. Energy, exergy, and anergy analysis present in this paper to investigate the system performance as well as its components. To accomplish this, a 4-ton vertical split air conditioner based on vapor compression refrigeration cycle charged with refrigerant R-22 was modified for experimental analysis. The results showed that during 540
... Show MoreIn Iraq most of the small buildings deployed a conventional air conditioning technology which typically uses electrically driven compressor systems which exhibits several clear disadvantages such as high energy consumption, high electricity at peak loads. In this work a thermal performance of air conditioning system combined with a solar collector is investigated theoretically. The hybrid air conditioner consists of a semi hermetic compressor, water cooled shell and tube condenser, thermal expansion valve and coil with tank evaporator. The theoretical analysis included a simulation for the solar assisted air-conditioning system using EES software to analyze the effect of different parameters on the power consumption of c
... Show MoreAn experimental and theoretical study has been done to investigate the thermal performance of different types of air solar collectors, In this work air solar collector with a dimensions of (120 cm x90 cm x12 cm) , was tested under climate condition of Baghdad city with a (43° tilt angel) by using the absorber plate (1.45 mm thickness, 115 cm height x 84 cm width), which was manufactured from iron painted with a black matt.
The experimental test deals with five types of absorber:-
Conventional smooth flat plate absorber , Finned absorber , Corrugated absorber plate, Iron wire mesh on absorber And matrix of porous media on absorber .
The hourly and average efficiency of the collectors
... Show MoreFlat-plate collector considers most common types of collectors, for ease of manufacturing and low price compared with other collectors. The main aim of the present work is to increase the efficiency of the collector, which can be achieved by improving the heat transfer and minimize heat loss experimentally. Five types of solar air collectors have been tested, which conventional channel with a smooth absorber plate (model I), dual channel with a smooth absorber plate (model II), dual channel with perforating “V” corrugated absorber plate (model III), dual channel with internal attached wire mesh (model Ⅳ), and dual channel with absorber sheet of transparent honeycomb, (model Ⅴ). The dual channel collector used for
... Show MoreIn this paper, an experimental study was conducted to enhance the thermal performance of a double-pass solar air heater (SAH) using phase change material (PCM) for thermal storage at climatic conditions of Baghdad city - Iraq. The double-pass solar air heater integrated with thermal storage system was manufactured and tested to ensure that the air heating reserved after the absence of the sun. The rectangular cavity filled with paraffin wax was used as a latent heat storage and incorporated into the lower channel of solar air heater. Experiments were carried out to evaluate the charging and discharging characteristics of two similar designed solar air collectors with and without using phase change material at a constant
... Show MoreIn this paper, an experimental analysis of conventional air-cooled and microchannel condensers in automotive vapor compression refrigeration cycle concerning heat transfer coefficient and energy using R134a as a refrigerant was presented. The performance of two condensers and cycles tested regarding ambient temperature which it was varied from 40oC to 65oC, while the indoor temperature and load have been set to be 23oC and 2200 W respectively. Results showed that the microchannel condenser has 224 % and 77 % higher refrigerant side and air side heat transfer coefficient respectively than the coefficients of the conventional condenser. Thus, the COP, in case of using the microchannel
... Show MoreGaining the relationship between the central government and local governments is great importance especially after the expanded functions of the central government and became unable to carry out their works without all that delegate or transfer parts of its powers to lower levels.
The aims of the research is to determine the relationship of the central government with the local government in accordance with the principle of administrative decentralization with the presentation of the competent authorities, the control of local governments, according to the Provincial Council Act No. 21 of 2008 amended.
The research has a problem that has been the relationship of the central
... Show MoreThe trade war, of course, leads to a sharp tension in international relations because the economy is the lifeblood of the states. In the world of trade and economy, countries began to lean towards cooperation. Economic relations after World War II were more liberal, trade barriers were removed and global trade became more flexible and smooth