Objective: An efficient solution for stabilization is the mobilization of the joints for the arthrokinematics affected by the positional defect of the CAI (i.e. chronic ankle instability). This study put to comparison the impacts of ankle dorsi flexion range of motion (DFROM) as well as dynamic balance ability (DBA) in the patients who have CAI using PJM (i.e. passive joint mobilization), a technique typically been used in previous works, and active joint mobilization (AJM), a technique which could have a greater impact on cortical excitability with the spontaneous movement. Design: rehabilitation program to treat recurrent ankle. Methods: A total of 10 players from the Iraqi clubs Muay Thai team were registered, 5 from each of the AJM and PJM groups. A total of 12 intervention sessions overall, lasting 10 mins each, were given to each participant over the course of three weeks. AJM employed angular motion of the joints to produce the patient's voluntary motion regarding lateral malleolus posterior gliding as well as medial malleolus anterior gliding, respectively, while PJM utilized Maitland's mobilization approach to perform mobilization of the joints with the talus in the posterior direction. Tape was used for measuring the ankle's DFROM, and the balance system was used to assess the ankle's DBA. Results: With the exception of DBA-right and DBA-anterior variables with regard to PJM group, considerable enhancements were seen following intervention in AJM as well as groups of the PJM. DBA-anterior, DFROM, DBA-right, and DBA-posterior, measures showed statistically significant differences between the PJM group and the AJM group. Conclusions: Joint mobilization, such as voluntary movement, was more successful thanks to the overall improvement regarding DBA and DFROM. The ankle's neuromuscular system is significantly impacted in the case when voluntary movement is present.
Abstract Kidney stones are one of the most common and most painful medical problems known (1). Nurses assess and monitor patients through diagnosis and treatment and teach patients how to avoid recurrence of stones (2). A descriptive study was conducted on 150 patients diagnosed with recurrent kidney stones, who were attending the out patients consultation urology disease clinics at surgical specialties, Al-Kadhimia, Al-Yarmook, and Al-Karama Teaching Hospital and Extracorporeal shock wave lithotripsy (ESWL) departments for the period from the 1st of Feb. 2002 through to the end of May 2004. The aim of
KE Sharquie, SA Al Mashhadani, AA Noaimi, RK Al-Hayani, SA Shubber, Iraqi Postgraduate Medical Journal, 2012 - Cited by 1
KE Sharquie, SA Al-Mashhadani, A A Noaimi, RK Al-Hayani, SA Shubber, Iraqi Journal of Community Medicine, 2017 - Cited by 1
We propose a novel strategy to optimize the test suite required for testing both hardware and software in a production line. Here, the strategy is based on two processes: Quality Signing Process and Quality Verification Process, respectively. Unlike earlier work, the proposed strategy is based on integration of black box and white box techniques in order to derive an optimum test suite during the Quality Signing Process. In this case, the generated optimal test suite significantly improves the Quality Verification Process. Considering both processes, the novelty of the proposed strategy is the fact that the optimization and reduction of test suite is performed by selecting only mutant killing test cases from cumulating t-way test ca
... Show MoreBackground: The spleen is the most common solid
organ injured in patients who had sustained abdominal
trauma. Such injuries to the spleen represent
approximately one quarter of all blunt injuries of the
abdominal viscera.
Due to its remarkable vasculature and its fragile
structure, splenic rupture is the most widespread cause
of intra-abdominal hemorrhage.
Objective: To assess the magnitude of splenic injury,
the management of splenic injury, and to evaluate the
postoperative complications.
Methods: A prospective study of 57 cases of splenic
injury was performed in Al-Kadhimiya Teaching
Hospital during the period between the 1st of October
2004 and the 1st of October 2006. Statistical analysis
This paper deals with calculate stresses in Knee-Ankle-Foot-Orthosis as a result of the effect vibration during gait cycle for patient wearing KAFO .Experimental part included measurement interface pressure between KAFO and leg due to action muscles and body weigh on Orthosis. also measurement acceleration result from motion of defected leg by accelerometer .Results of Experimental part used input in theoretical part so as to calculate stresses result from applying pressure and acceleration on KAFO by engineering analysis program ANSYS 14.Resultes show stresses values in upper KAFO greater than lower KAFO that is back to muscles more effective in thigh part lead to recoding pressure higher than pressure in shank part.
This study deals with knowing the public relations activities of the Integrity Commission for the year 2007, knowing the contents of these activities, knowing the contents of the advertisements that it published, whether the contents of the advertisements were convincing, and whether press photographs were used in these advertisements, as well as whether symbols and slogans were used. What language and words were used to address the recipient? 1- What feelings do the contents of advertisements arouse? 2- Research objectives: This research aims to answer the following questions: What are the public relations activities carried out by the Integrity Commission? B: Are the contents of the advertisements published by the Authority convincing to
... Show MoreAmorphization of drug has been considered as an attractive approach in improving drug solubility and bioavailability. Unlike their crystalline counterparts, amorphous materials lack the long-range order of molecular packing and present the highest energy state of a solid material. Co-amorphous systems (CAM) are an innovative formulation technique by where the amorphous drugs are stabilized via powerful intermolecular interactions by means of a low molecular co-former.
This review highlights the different approaches in the preparation of co-amorphous drug delivery system, the proper selection of the co-formers. In addition, the recent advances in characterization, Industrial scale and formulation will be discussed.