Preferred Language
Articles
/
XRY-CocBVTCNdQwChDHx
Post-fire serviceability and residual strength of composite post-tensioned concrete T-beams
...Show More Authors
Abstract<p>In this study, the response of ten composite post-tensioned concrete beams topped by a reinforced concrete deck with adequate reinforcing shear connectors is investigated. Depending on the concrete compressive strength of the deck slab (20, 30, and 40 MPa), beams are grouped into three categories. Seven of these beams are exposed to a fire attack of 700 and 800 °C temperature simultaneously with or without the presence of a uniformly distributed sustained static loading. After cooling back to ambient temperature, these composite beams are loaded up to failure, using a force control module, by monotonic static loading in a four-point-bending setup with two symmetrical concentrated loads applied in the middle third of the effective span. The objectives of this study include investigating the behavior of the composite prestressed concrete beams under and after the exposure to a direct fire flame, as well as finding their residual load-carrying capacity. Tests demonstrate significant deteriorations caused by exposure to high temperatures associated with the increase of the member’s camber. The increase of the midspan camber after heating exposure reached approximately 200%. On the other hand, the 1-h steady-state exposure of test specimens to temperatures of 700 and 800 °C led to reduce the load-carrying capacity of the heat-deteriorated beams up to 45% and 54%, respectively.</p>
Crossref
Publication Date
Sun Feb 10 2019
Journal Name
Iraqi National Journal Of Nursing Specialties
Nurses' Practices regarding Patients Discharge Planning post Cardiac Surgery at Cardiac Centers in Baghdad city
...Show More Authors

Objective (s): to assess nurses' practices regarding discharge planning post-cardiac surgery and to find out the relationship between nurse practices and demographic characteristic (age, gander, level of education, years of experiences, and years of experiences in surgical ward).
Methodology: A descriptive study was carried out at cardiac centers and hospitals in Baghdad (Ibn Al- Bitar specialized center for cardiac surgery; Iraqi center for heart disease and Ibn al Nafees hospital). For the period of 6th February 2017 up to 1st of June 2018. A non-probability (purposive) sample of (58) nurses (male & female) who were working in surgical wards. The data was collected, by using of a questionnaire, which consists of two parts, part

... Show More
View Publication Preview PDF
Publication Date
Tue Jun 16 2020
Journal Name
Frontiers In Pharmacology
Administration of Δ9‐Tetrahydrocannabinol (THC) Post‐Staphylococcal Enterotoxin B Exposure Protects Mice From Acute Respiratory Distress Syndrome and Toxicity
...Show More Authors

View Publication Preview PDF
Scopus (26)
Crossref (21)
Scopus Clarivate Crossref
Publication Date
Sat Jun 15 2019
Journal Name
Journal Of Baghdad College Of Dentistry
Oral hygiene status in relation to salivary estradiol hormone level among pre-menopausal and post-menopausal Iraqi women
...Show More Authors

Background: The menopause is physiological changes in women that give rise to adaptive changes at both systemic and oral level. During menopause, ovarian function declines and the production of sex steroid hormones reduces significantly affecting the oral tissues and periodontal structures leading to chronic inflammation of the gingiva, increased risk of tooth loss. Aim of study: The present study was designed to estimate the oral hygiene status in relation to salivary estradiol level among pre and post-menopausal women. Materials and Methods: Ninety women aged 48-52 years old, the control group consisted of 45 pre-menopausal women and the study group consisted of 45 post-menopause were examined for gingival index, plaque index and calcu

... Show More
View Publication
Scopus (2)
Crossref (2)
Scopus Crossref
Publication Date
Tue Jun 15 2021
Journal Name
Al-academy
Forms of post-modernism in performance of Iraqi theatre "dream of Baghdad exam": عمار عبد سلمان محمد
...Show More Authors

  The effects of postmodernism on theatrical form was managed by the director (Anas Abdul Samad) to be employed in the Iraqi play (Dream in Baghdad) and the researcher sought to study this problem and divided it into four chapters dealt with in the first chapter the problem of research and its need, the importance of research, As well as the definition of terminology, either Chapter II theoretical framework divided by the researcher to the first two is the postmodernism in the theater is the most prominent reference references and the second most important postmodern applications in the world play and then the researcher concluded the second chapter of the most important indicators. In the third chapter, the researcher identified th

... Show More
View Publication Preview PDF
Crossref
Publication Date
Fri Mar 20 2020
Journal Name
Fibers
Influence of Cooling Methods on the Behavior of Reactive Powder Concrete Exposed to Fire Flame Effect
...Show More Authors

The construction of highly safe and durable buildings that can bear accident damage risks including fire, earthquake, impact, and more, can be considered to be the most important goal in civil engineering technology. An experimental investigation was prepared to study the influence of adding various percentages 0%, 1.0%, and 1.5% of micro steel fiber volume fraction (Vf) to reactive powder concrete (RPC)—whose properties are compressive strength, splitting tensile strength, flexural strength, and absorbed energy—after the exposure to fire flame of various burning temperatures 300, 400, and 500 °C using gradual-, foam-, and sudden-cooling methods. The outcomes of this research proved that the maximum reduction in mechanical prop

... Show More
View Publication
Scopus (5)
Crossref (4)
Scopus Clarivate Crossref
Publication Date
Sat Aug 01 2020
Journal Name
Key Engineering Materials
Response of Damaged Reinforced Concrete Beams Strengthened with NSM CFRP Strips
...Show More Authors

This paper presents a study (experimentally) for strengthening reinforced concrete (RC) beams with Near-Surface-Mounted (NSM) technique. The use of this technique with CFRP strips or rebars is an efficient technology for increasing the strength for flexure and shear or for repairing damaged reinforced concrete (RC) members. The objective of this research is to study, experimentally, RC beams either repaired or strengthened with NSM CFRP strips and follow their flexural behavior and failure modes. NSM-CFRP strips were used to strengthen three RC beam specimens, one of them was initially strengthened and tested up to failure. Four beam specimens have been initially subjected to preloading to 50% and 80% of ultimate load. Two of the sp

... Show More
View Publication
Crossref (1)
Crossref
Publication Date
Sat Jan 01 2022
Journal Name
Journal Of The Mechanical Behavior Of Materials
Performance of reinforced concrete non-prismatic beams having multiple openings configurations
...Show More Authors
Abstract<p>This experimental study demonstrates the gable-reinforced concrete beams’ behavior with several number of openings (six and eight) and posts’ inclination, aimed to find the strength reduction in this type of beam. The major results found are: for the openings extending over similar beam length it is better to increase the number of posts (openings), <italic>i.e.</italic>, increasing opening number led to decrease in opening area, which allows us to transmit stresses and act as lever arms between the upper and the lower chords. Also, findings revealed that the inclined posts have larger loading at the mid-point relative to vertical ones. For gables with vertical posts hav</p> ... Show More
View Publication Preview PDF
Scopus (6)
Crossref (6)
Scopus Clarivate Crossref
Publication Date
Sat Jan 01 2022
Journal Name
Journal Of The Mechanical Behavior Of Materials
Analysis of concrete beams reinforced by GFRP bars with varying parameters
...Show More Authors
Abstract<p>Structural buildings consist of concrete and steel, and these buildings have confronted many challenges from various aggressive environments against the materials manufactured from them. It contains high water levels and buildings whose concrete cover may be damaged and thus lead to the deterioration and corrosion of steel. It was important to have an alternative to steel, such as the glass fiber reinforced polymer (GFRP), which is distinguished by its great effectiveness in resisting corrosion, as well as its strong tensile resistance. Still, one of its drawbacks is that it has a low modulus of elasticity. This research article aims to conduct a numerical study using the nonlinear fi</p> ... Show More
Scopus (14)
Crossref (13)
Scopus Clarivate Crossref
Publication Date
Wed Oct 10 2018
Journal Name
Steel And Composite Structures
Removable shear connector for steel-concrete composite bridges
...Show More Authors

The conception and experimental assessment of a removable friction-based shear connector (FBSC) for precast steel-concrete composite bridges is presented. The FBSC uses pre-tensioned high-strength steel bolts that pass through countersunk holes drilled on the top flange of the steel beam. Pre-tensioning of the bolts provides the FBSC with significant frictional resistance that essentially prevents relative slip displacement of the concrete slab with respect to the steel beam under service loading. The countersunk holes are grouted to prevent sudden slip of the FBSC when friction resistance is exceeded. Moreover, the FBSC promotes accelerated bridge construction by fully exploiting prefabrication, does not raise issues relevant to precast co

... Show More
View Publication
Scopus (39)
Scopus Clarivate
Publication Date
Wed Nov 28 2018
Journal Name
International Journal Of Engineering &amp; Technology
Modified Strut Effectiveness Factor for FRP-Reinforced Concrete Deep Beams
...Show More Authors

A few examinations have endeavored to assess a definitive shear quality of a fiber fortified polymer (FRP)- strengthened solid shallow shafts. Be that as it may, need data announced for examining the solid profound pillars strengthened with FRP bars. The majority of these investigations don't think about the blend of the rigidity of both FRP support and cement. This examination builds up a basic swagger adequacy factor model to evaluate the referenced issue. Two sorts of disappointment modes; concrete part and pulverizing disappointment modes were examined. Protection from corner to corner part is chiefly given by the longitudinal FRP support, steel shear fortification, and cement rigidity. The proposed model has been confirmed util

... Show More
View Publication
Crossref (1)
Crossref