Preferred Language
Articles
/
XBagoIgBVTCNdQwCdHnd
Patellar Fracture Fixation by Cerclage and Tension Band Wiring Technique versus Kirschner wires and Tension Band Wiring Technique
...Show More Authors

Background:Fractures of patella constitute 1% of all fractures. Various techniques have been described for internal fixation of patella fractures. Superiority of one technique over the other has long been debated. Objective:We reviewed a series of seventy patients with transverse or comminuted fractures of patella treated with cerclage and tension band wiring technique to assess if it had any advantages over k. wires and tension band wiring technique. Type of the study:Retrospective study.Methods; Seventy patients with displaced patella fracture, with a mean age of 47 years (range 13-75) were divided into two groups :group A 36 patients were treated with cerclageand tension bands technique ,and group B 34 patients were fixed by 2 K. wires and tension bands technique. Clinical outcome was assessed using the system of Bostman score. Range of motion and evidence of radiological union were assessed at regular follow-ups. Results; All patients in group A gained Excellent result and good result, while only one patient gained poor result in group B . One patient (2.8%) developed superficial infection in group A and three patients( 8.8% ) developed superficial infection in group B. All fractures had united at the end of 10 weeks. Twenty two patients (31.4%) underwent a second surgery for wire removal; 5 cases in group A ( 13.9 % ) two of them due to implant related complications and 15 ( 44.1%) patients for group B mainly due to pain and interference with daily activity. Malunion or non-union was not noted in any of the cases. . Conclusion; The advantages of the cerclage and tension bands technique for fixation of displaced patella fracture are early mobilization, elimination of k-wire related complications, and ease of use in comminuted fracture pattern as well and a lower reoperation rates as compared to other method of fixation by 2 K. wires and tension bands technique. We strongly recommend its use in cases of displaced comminuted transverse fractures of patella

View Publication Preview PDF
Quick Preview PDF
Publication Date
Tue Dec 31 2024
Journal Name
Bulletin Of The Chemical Society Of Ethiopia
Extraction and preconcentration of many metals ions by using CPE technique
...Show More Authors

Cloud point extraction is a simple, safe, and environmentally friendly technique for preparing many different kinds of samples. In this review, we discussed the CPE method and how to apply it to our environmental sample data. We also spoke about the benefits, problems, and likely developments in CPE. This process received a great deal of attention during preconcentration and extraction. It was used as a disconnection and follow-up improvement system before the natural mixtures (nutrients, polybrominated biphenyl ethers, pesticides, polycyclic sweet-smelling hydrocarbons, polychlorinated compounds, and fragrant amines) and inorganic mixtures were examined and many metals like (silver, lead, cadmium, mercury, and so on). We also find

... Show More
View Publication
Scopus (3)
Crossref (1)
Scopus Clarivate Crossref
Publication Date
Tue Aug 01 2017
Journal Name
International Journal Of Advanced Research In Computer And Communication Engineering
Information hiding by using Developed M8PAM Technique
...Show More Authors

Publication Date
Wed Jun 12 2019
Journal Name
Dirasat: Human And Social Sciences
Teaching by pause technique in the classroom
...Show More Authors

Communication represents the essence of language learning. Since the unspecified evolution of conveying information, human beings have been employing the main constituents of language with short pauses. Although the punctuation marks necessitate short expressions among thought group of words in writing, human language demand for understanding how and when to pause orally. This paper presents the pause technique in the classroom. It signifies the relation between pausing and lecturing in the class and determines its sufficient time-management to interact with college learners of different specializations. The conduct study reviewed teaching pause technique in the empirical studies at Special Education and Communication Disorders of Pennsylva

... Show More
View Publication Preview PDF
Scopus (1)
Scopus
Publication Date
Mon Dec 03 2018
Journal Name
The Iraqi Postgraduate Medical Journal
Operative Treatment by Plate and Screws Versus Conservative Treatment of Closed Displaced Fracture of the Mid Third of Clavicle in Adults: Comparative Study
...Show More Authors

BACKGROUND: Clavicle fractures are common injuries in young active individuals, the mid third of the clavicle is most commonly fractured part(80% of clavicle fracture) OBJECTIVE: To compare the outcomes of operative and non operative management of displaced and or comminuted closed fracture of the mid third of clavicle in young adults PATIENTS AND METHODS: This prospective observational study of 24 patients of fracture of the mid third of the clavicle was conducted in Alkindy teaching hospital from July 2015 to January 2017 and divided into two groups; one managed by operative treatment with plate and screws and the other by non operative sling immobilization after taking the consent and the patients were seen at 2, 4, 6 weeks,3, 6, and 9 m

... Show More
View Publication Preview PDF
Publication Date
Mon Sep 01 2008
Journal Name
Al-khwarizmi Engineering Journal
Design and Simulation of GaussianFSK Transmitter in UHF Band Using Direct Modulation of ΣΔ Modulator Fractional-N Synthesizer
...Show More Authors

This research involves design and simulation of GaussianFSK transmitter in UHF band using direct modulation of ΣΔ  fractional-N synthesizer with the following specifications:

Frequency range (869.9– 900.4) MHz, data rate 150kbps, channel spacing (500 kHz), Switching time 1 µs, & phase noise @10 kHz = -85dBc.

New circuit techniques have been sought to allow increased integration of radio transmitters and receivers, along with new radio architectures that take advantage of such techniques. Characteristics such as low power operation, small size, and low cost have become the dominant design criteria by which these systems are judged.

A direct modulation by ΣΔ  fractional-N synthesizer is proposed

... Show More
View Publication Preview PDF
Publication Date
Tue Jul 01 2008
Journal Name
Journal Of Educational And Psychological Researches
Synthesis of 1,3 – Diazepine -4-7 diones Analogue to valium which is used for the control of anxiety, tension states and an antidepressant
...Show More Authors

Oxazepine [1] is non – nomologous seven –member ring  that contain two netroatoms (oxygen and nitrogen ). Meanwhile diazepine [2] contains to nitrogen atoms in seven – member  ring.

       
     
   
 

 

 

 

 

 

 

Diazepam (valium) [3] is used to relive anxiety tension associated with anxiety disorder and muscle spasms (1, 2, 3

... Show More
View Publication Preview PDF
Publication Date
Mon Jun 03 2019
Journal Name
Rawal Medical Journal
SUPERIOR VERSUS ANTERIOR PLATING OF MIDSHAFT CLAVICLE FRACTURE IN ADULT COMPARATIVE STUDY
...Show More Authors

Clavicle fractures are common injuries in young, active individuals. The majority of the fractures (80% to 85%) occur in the mid-shaft of the bone and account for approximately 2.6% of all fractures. For many years the standard treatment of fracture clavicle was the "figure-of-eight" bandage but several indications for operative fixation, the position of plate fixation for clavicle fracture remains controversial. The aim of this study is to compare between anterio—inferior and anterior-superior plating of mid-shaft displaced clavicle fracture in complications, plate prominence, nonunion, malunion and range of motion. This study is a prospective study conducted in Al-Kindy teaching hospital .A total of 30 patients with fracture mid –sh

... Show More
View Publication Preview PDF
Publication Date
Thu Jun 30 2022
Journal Name
Iraqi Journal Of Laser
PDF Towards C+L Band Three-Mode (De)Multiplexer Using Subwavelength Grating (SWG) Technology
...Show More Authors

Abstract: Recently, there is increasing interest in using mode-division multipelexing (MDM) technique  to enhace  data rate transmission over multimode fibers.  In this technique, each fiber mode is treated as a separate optical carrier to transfer its own data.  This paper presents a broadband, compact, and low loss three-mode (de)multiplexer designed for C+L band using subwavelength grating (SWG) technology and built-in silicon-on-insulator SOI platform. SWG offers refractive index engineering for wider operating bandwidth and compact devices compared to conventional ones. The designed (de)multiplex deals with three modes (TE0, TE1, and TE2) and has a loss > -1 dB and crosstalk < −15 dB, and its operation c

... Show More
View Publication Preview PDF
Publication Date
Thu Sep 12 2019
Journal Name
Al-kindy College Medical Journal
K. wire fixation versus conservative treatment of closed displaced intra-articular calcaneal fractures
...Show More Authors

Background: Calcaneus is a spongy cancellous bone with rich blood supply , its fracture heals more rapidly providing no occurrence of infection and soft tissue injury around ,no gross malposition of fragments. The associated pain leads to a major impairment in life quality. The aim of treatment for calcaneal fractures is the decrease of pain and rebuilding of walking ability for patients with normal foot shape and the ability to wear normal foot wear. To reduce complications, a minimally invasive technique for the treatment of displaced intra-articular fractures of the calcaneus was preferred to use. The purpose of this study was to determine whether the closed reduction and percutaneous K. wire fixation of displaced intra-art

... Show More
Preview PDF
Crossref
Publication Date
Fri Jan 01 2021
Journal Name
Aip Conference Proceedings
Structural characterization of nickel and zinc aluminate prepared by sol-gel technique
...Show More Authors

This work concerned on nanocrystalline NiAl2O4 and ZnAl2O4 having spinel structure prepared by Sol–gel technique. The structural and characterization properties for the obtained samples were examined using different measurements such as X-ray diffraction (XRD), Fourier transform infrared spectroscopy (FTIR), finally, Field emission scanning electron microscope (FESEM).The Spinel-type for two prepared compound (NiAl2O4) and (ZnAl2O4) at different calcination temperature examined by XRD. Williamson-Hall Methods used to estimate crystallite size, Average distribution crystallite size of two compound were, 34.2 nm for NiAl2O4 and32.6 for ZnAl2O4, the increase in crystallite size affecting by increasing in calcination temperature for both comp

... Show More
View Publication Preview PDF
Scopus Crossref