Laboratory model tests were performed to investigate the behavior of shallow and inclined skirted foundations placed on sandy soil with R.D%=30 and the extent of the impact of the positive and negative eccentric-inclined loading effect on them. To achieve the experimental tests, it was used a box of (600×600) mm cross-sectional and 600mm in height and a square footing of (50*50) mm and 10 mm in thickness attached to the skirt with Ds=0.5B and various an angle of (10°, 20°, 30°). The results showed that using skirts leads to a significant improvement in load-carrying capacity and decreased settlement. In addition, when the skirt angle increased, the ultimate load improved. Load-carrying capacity decreased with increasing eccentricity and load inclination. For load inclination (Beta) 15° when the eccentricity changed from e=0.15B to e=0.05B, the load improvement percentages were (323.2 to 263%) and (214 to 220%). The settlement reduction factor was (83 to 78%) and (62 to 58%) for positive and negative eccentric-inclined loading, respectively. Also, the result showed that the positive effect on reducing soil-bearing capacity is more than the negative. Increasing eccentricity increases the improvement percentage for positive eccentric-inclined load and decreases for the case of negative eccentric-inclined load. Increased skirt angle will increase the Improvement factor (IR). When the skirt angle increased from 10° to 30° for an improved foundation with load angles of 5°, 10°, and 15°, the improvement factor (IR) increased from (2.53, 2.51, 2.4) to (3.45, 3.65, 3.97) and (2.43, 2.58, 2.54) to (4, 4.63, 5.3) for both negative and positive eccentric-inclined load respectively and settlement reduction factor for load angle 15° and skirt angle increase from 10° to 30° were 34% and 27% for positive and negative eccentric-inclined load respectively. The (IR) for the positive eccentric-inclined load is more than the negative eccentric-inclined load for all cases. In addition, the skirt angle of 30° significantly improved the improvement factor (IR).
This research investigates manganese (Mn) extraction from Electric Arc Furnace Steel Slag (EAFS) by using the Liquid-liquid extraction (LLE) method. The chemical analysis was done on the slag using X-ray fluorescence, X-ray diffraction, and atomic absorption spectroscopy. This work consisted of two parts: the first was an extensive study of the effect of variables that can affect the leaching process rate for Mn element from slag (reaction time, nitric acid concentration, solid to liquid ratio, and stirring speed), and the second part evaluates the extraction of Mn element from leached solution. The results showed the possibility of leaching 83.5 % of Mn element from the slag at a temperature of 25°C, nitric acid co
... Show MoreProteus mirabilis isolates have been intensively researched for their capacity to cause urinary tract infections (UTIs) and their swarming motility, although little is known about this phenomenon. Probiotic Lactobacillus species, which are beneficial bacteria, are being studied worldwide as therapeutic and preventative agents against bacterial infections. This study investigated Lactobacillus supernatants as a potential new treatment against Proteus mirabilis. In addition to testing their antimicrobial and anti-swarming activities, the research also aimed to understand the genetic mechanisms behind the observed phenotypic changes. Methods. A total of 150 urine specimens were collected from UTI patients at various hospitals in Baghdad. Dire
... Show MoreThe complexity and partially defined nature of jet grouting make it hard to predict the performance of grouted piles. So the trials of cement injection at a location with similar soil properties as the erecting site are necessary to assess the performance of the grouted piles. Nevertheless, instead of executing trial-injected piles at the pilot site, which wastes money, time, and effort, the laboratory cement injection devices are essential alternatives for evaluating soil injection ability. This study assesses the performance of a low-pressure laboratory grouting device by improving loose sandy soil injected using binders formed of Silica Fume (SF) as a chemical admixture (10% of Ordinary Portland Cement OPC mass) to di
... Show MoreThe blade pitch angle (BPA) in wind turbine (WT) is controlled to maximize output power generation above the rated wind speed (WS). In this paper, four types of controllers are suggested and compared for BPA controller in WT: PID controller (PIDC), type-1 fuzzy logic controller (T1-FLC), type-2 fuzzy logic controller (T2-FLC), and hybrid fuzzy-PID controller (FPIDC). The Mamdani and Sugeno fuzzy inference systems (FIS) have been compared to find the best inference system used in FLC. Genetic algorithm (GA) and Particle swarm optimization algorithm (PSO) are used to find the optimal tuning of the PID parameter. The results of500-kw horizontal-axis wind turbine show that PIDC based on PSO can reduced 2.81% in summation error of power
... Show MoreA recent study compared experimentally the hydraulic and thermal activity of twisted tape inserts for two types, metal foam twisted tape (MFTT) and traditional twisted tape (TTT), in a double pipe heat exchanger. The investigation goal of the innovatively designed MFTT is to enhance the heat transfer process, which provides a higher thermal enhancement factor over those of TTT under the same conditions. Heat transfer activity in terms of Nusselt number (
This paper presents the implementation of a complex fractional order proportional integral derivative (CPID) and a real fractional order PID (RPID) controllers. The analysis and design of both controllers were carried out in a previous work done by the author, where the design specifications were classified into easy (case 1) and hard (case 2) design specifications. The main contribution of this paper is combining CRONE approximation and linear phase CRONE approximation to implement the CPID controller. The designed controllers-RPID and CPID-are implemented to control flowing water with low pressure circuit, which is a first order plus dead time system. Simulation results demonstrate that while the implemented RPID controller fails to stabi
... Show MoreIn this study the Entrance Surface Dose (ESD) received by pediatrics patients undergoing chest, abdomen and skull X-ray examinations was estimated. The study was conducted in two hospitals in Najaf city where three radiographic systems were considered. The study participants were classified into four age groups 0-1 , 1-5 , 5-10 and 10-15 years. Calculations were performed using exposure factors, kVp, mAs and focal-skin distance, together with patient data age. The ESD was calculated for the involved patients who underwent an Antero-posterior (AP) chest, abdomen and skull X-ray examination. The resulted data were analyzed and compared with international dose references. For all studied radiographic examinations and all X-ray mac
... Show More