Preferred Language
Articles
/
WhYP44sBVTCNdQwCKeNM
Illumination - Invariant Facial Components Extraction Using Adaptive Contrast Enhancement Methods
...Show More Authors

The process of accurate localization of the basic components of human faces (i.e., eyebrows, eyes, nose, mouth, etc.) from images is an important step in face processing techniques like face tracking, facial expression recognition or face recognition. However, it is a challenging task due to the variations in scale, orientation, pose, facial expressions, partial occlusions and lighting conditions. In the current paper, a scheme includes the method of three-hierarchal stages for facial components extraction is presented; it works regardless of illumination variance. Adaptive linear contrast enhancement methods like gamma correction and contrast stretching are used to simulate the variance in light condition among images. As testing material a subset consists of 1150 images belong to 91 different subjects was taken from Cohn-Kanade AU coded dataset (CK); the subjects images hold different facial expressions. The test results show the effectiveness of the proposed automated localization scheme in different illuminations conditions; it gave accuracy of about 95.7%.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Sun Jun 12 2011
Journal Name
Baghdad Science Journal
Dependence of gamma-ray absorption coefficient on the size of lead particle
...Show More Authors

In this study, dependence of gamma-ray absorption coefficient on the size of Pb particle size ranging from 200µm up to 2.5mm, using different weights of each particle size. The results show that gamma-ray attenuation coefficient is inversely proportional with the size of Pb particle size due to the reduction of the spaces between the lead particles.

View Publication Preview PDF
Crossref
Publication Date
Mon Dec 20 2021
Journal Name
Baghdad Science Journal
Dosimetric Verification of Gamma Passing Rate for Head and Neck Cases Treated with Intensity Modulated Radiation Therapy (IMRT) Treatment Planning Technique
...Show More Authors

Each Intensity Modulated Radiation Therapy (IMRT) plan needs to be tested and verified before any treatment to check its quality. Octavius 4D-1500 phantom detector is a modern and qualified device for quality assurance procedure. This study aims to compare the common dosimetric criteria 3%/3 mm with 2%/2 mm for H&N plans for the IMRT technique. Twenty-five patients with head and neck (H&N) tumor were with 6MV x-ray photon beam using Monaco 5.1 treatment planning software and exported to Elekta synergy linear accelerator then tested for pretreatment verification study using Octavius 4D-1500 phantom detector. The difference between planned and measured dose were assessed by using local and global gamma index (GI) analysis method at

... Show More
View Publication Preview PDF
Scopus (2)
Scopus Clarivate Crossref
Publication Date
Sun Sep 05 2010
Journal Name
Baghdad Science Journal
Calculation the number buildup factor of cylindrical samples for Brass, Copper & lead
...Show More Authors

The buildup factor of cylindrical samples (shields) for Brass, Copper & lead (Brass, Cu, Pb (was studied, where buildup factor were calculated with thickness between (0-12) m.f.p. for Co60 and Cs137sources with activities (30) & (41) MBq respectively , using scintillation detector NaI(T?) with (3"×3")volume .The results shows increases of buildup factor for low atomic number(Z) samples where the energy of radiation source was constant, also shows increases of buildup factor with decreases the energy of radiation source. An empirical equation was obtained using Matlab7 program this equation have agreements with most obtained data for 96%.

View Publication Preview PDF
Crossref
Publication Date
Wed Dec 01 2010
Journal Name
Iraqi Journal Of Physics
Neutron Yield From Gamma Ray Incineration of Radioactive Fission Products
...Show More Authors

The neutron flux in this paper, which is generated as a result of γ incineration of the radioactive fisssion products isotopes has been evaluated .It is obvious from this paper that the neutron flux value depends on the number of incineration nuclei and the nuclear cross-section of the incinerated isotopes, and the neutron flux is directly dependent on γ-ray flux. The neutron flux increases from 1010to 1017n/s.gm as the irradiation flux increases from 1016to 1020 γ/cm2.s. It is concluded that the γ-incineration technique can be used to produce a switchable neutron source of high flux.

View Publication Preview PDF
Publication Date
Sun Jun 05 2016
Journal Name
Baghdad Science Journal
Measurement of radionuclides in imported Coffee Consumed in Basra southern of Iraq and estimation of its annual effective dose
...Show More Authors

Radioactive elements were identified in samples of imported coffee consumed in the province of Basra using gamma spectrometry SAM940TM. It is a scintillation detector of NaI(Tl) crystal and the dimensions of 2×2 inch. We have identified specific concentration As(Bq/kg) and annual effective dose D(Sv/y) for radioactive elements (_^40)K, (_^131)I, (_^134)Cs and (_^137)Cs. The estimated average effective dose for adults from coffee samples were found to be 0.037mSv/y, 88.434nSv/y, 46.909nSv/y, 27.212nSv/y for ((_^40)K,(_^131)I,(_^134)Cs,(_^137)Cs) respectively. The present results of the study revealed that the radioactivity was relatively low in the coffee and within the permissiblelimit.

View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Wed Jan 06 2021
Journal Name
Journal Of Planner And Development
Environmental dimensions and administrative mechanisms for the territory planning in Algeria, between theory and reality.
...Show More Authors

     In front of the serious deterioration of the elements of the environment, new convictions arose the need to integrate into the global environmental concerns as being one and the issue of shared responsibility and the impact of this conviction, the evolution of the environment protection law in many countries, including Algeria. Due to the multiplicity of perceptions about the environmental result of multiple scientific disciplines, the legislative concept emerged to protect the environment, which includes prevention and rational management and conservation and restoration and repair.

    Environmental planning for the various governments and countries aims to avert disasters and achieve the

... Show More
View Publication Preview PDF
Publication Date
Wed Feb 19 2020
Journal Name
International Journal Of Innovation, Creativity And Change
Secure Image Steganography Through Multilevel Security
...Show More Authors

The concealment of data has emerged as an area of deep and wide interest in research that endeavours to conceal data in a covert and stealth manner, to avoid detection through the embedment of the secret data into cover images that appear inconspicuous. These cover images may be in the format of images or videos used for concealment of the messages, yet still retaining the quality visually. Over the past ten years, there have been numerous researches on varying steganographic methods related to images, that emphasised on payload and the quality of the image. Nevertheless, a compromise exists between the two indicators and to mediate a more favourable reconciliation for this duo is a daunting and problematic task. Additionally, the current

... Show More
Publication Date
Sat Jul 01 2023
Journal Name
Journal Of Engineering
Comparative Reliability Analysis between Horizontal-Vertical-Diagonal Code and Code with Crosstalk Avoidance and Error Correction for NoC Interconnects
...Show More Authors

Ensuring reliable data transmission in Network on Chip (NoC) is one of the most challenging tasks, especially in noisy environments. As crosstalk, interference, and radiation were increased with manufacturers' increasing tendency to reduce the area, increase the frequencies, and reduce the voltages.  So many Error Control Codes (ECC) were proposed with different error detection and correction capacities and various degrees of complexity. Code with Crosstalk Avoidance and Error Correction (CCAEC) for network-on-chip interconnects uses simple parity check bits as the main technique to get high error correction capacity. Per this work, this coding scheme corrects up to 12 random errors, representing a high correction capac

... Show More
View Publication Preview PDF
Crossref
Publication Date
Wed Mar 16 2022
Journal Name
International Academic Journal Of Accounting And Financial Management
Analyzing and Measuring the Relationship between Public Spending and the Parallel Exchange Rate in the Iraqi Economy for the Period 2004-2022
...Show More Authors

Public spending represents the government’s financial leverage and has a significant impact on real and monetary economic variables, and one of these effects is the effect of public spending on the exchange rate as an important monetary variable for monetary policy, As we know that public spending in Iraq is financed from oil revenues sold in US dollars, and the Ministry of Finance converts the US dollar into Iraqi dinars to finance the government's need to spend within the requirements and obligations of the state's general budget, And converting the US dollar into Iraqi dinars has an impact on the parallel exchange market, even if there is a contractual exchange rate between the Ministry of Finance and the Central Bank of Iraq to

... Show More
View Publication Preview PDF
Crossref
Publication Date
Tue May 01 2012
Journal Name
Iraqi Journal Of Physics
Early detection of breast cancer mass lesions by mammogram segmentation images based on texture features
...Show More Authors

Mammography is at present one of the available method for early detection of masses or abnormalities which is related to breast cancer. The most common abnormalities that may indicate breast cancer are masses and calcifications. The challenge lies in early and accurate detection to overcome the development of breast cancer that affects more and more women throughout the world. Breast cancer is diagnosed at advanced stages with the help of the digital mammogram images. Masses appear in a mammogram as fine, granular clusters, which are often difficult to identify in a raw mammogram. The incidence of breast cancer in women has increased significantly in recent years.
This paper proposes a computer aided diagnostic system for the extracti

... Show More
View Publication Preview PDF