The level of thyroid autoantibodies between type 1 and type 2 diabetes mellitus
patients in Baghdad City were investigated.
Fifty individuals (25 female and 25 male) with type-1 DM in the age group of 10
to 35 years and seventy (35 female and 35 male) of having type-2 DM in the age
group of 33 to 60 years were investigated. A control group of twenty-five nondiabetes
was included. Serum sample collected was used to estimate anti-TPO, TG
and thyroid stimulating hormone antibodies (thyroid stimulating immunoglobulin
TSI and thyrotropin binding inhibitory immunoglobulin TBII) by using enzymelinked
immunosorbent assay (ELISA) technique.
The results show that there is a significant (p< 0.05) increase in the level
Chilled ceilings systems offer potential for overall capital savings. The main aim of the present research is to investigate the thermal performance of the indirect contact closed circuit cooling tower, ICCCCT used with chilled ceiling, to gain a deeper knowledge in this important field of engineering which has been traditionally used in various industrial & HVAC systems. To achieve this study, experimental work were implemented for the ICCCCT use with chilled ceiling. In this study the thermal performances of closed wet cooling tower use with chilled ceiling is experimentally and theoretically investigated. Different experimental tests were conducted by varying the controlling parameters to investigate their effects
... Show MoreBack ground: Viruses may be involved in the pathogenesis of Type 1 Diabetes Mellitus (T1DM), either through direct β-cell infection or as triggers of
autoimmunity.
Objective: To investigate the presence of specific anti- viral IgG antibodies for Coxsackie virus type B (CVB5), Poliovirus, and Adenovirus which proposed to be
involved in the etiology of T1DM.
Subjects & methods: A total of 60 Iraqi T1DM children were included in the presents study. They were new onset of the disease (diagnosis was from one week up
to five months). For the purpose of comparisons, 50 apparently healthy control subjects were selected. Serum IgG against Coxsackie virus type B5, Adenovirus type
3, 4, and 7, and Poliovac
Samples from tap water were chosen to be examined as one of the possible modes of G. lamblia and other parasites transmission. 144 domestic filter units were randomly distributed to houses in Baghdad in Al-Sadr City and surrounding regions then the suspended materials were examined microscopically by direct wet mount after centrifugal sedimentation method, and after staining with modified Ziehl-Neelsen (acid fast) stain. The results showed that 5/144 (3.47%) samples contained G. lamblia cysts, 3/144 (2.08%) contained E. histolytica/E. dispar cyst, while each of Cryptosporidium spp. and Cyclospora cayetanensis oocysts were observed in two samples (1.38%); also free living amoeba, ciliates and flagellates were detected in all samples. This
... Show MoreThe two body model of (Core+n) within the radial wave functions of the cosh potential has been used to investigate the ground state features such as the proton, neutron and matter densities, the root mean square (RMS) nuclear proton, neutron, charge and mass radii of unstable neutron-rich 14B, 15C, 19C and 22N nuclei. The calculated results show that the two body model with the radial wave functions of the cosh potential succeeds in reproducing neutron halo in these nuclei.
Two‐dimensional buoyancy‐induced flow and heat transfer inside a square enclosure partially occupied by copper metallic foam subjected to a symmetric side cooling and constant heat flux bottom heating was tested numerically. Finite Element Method was employed to solve the governing partial differential equations of the flow field and the Local Thermal Equilibrium model was used for the energy equation. The system boundaries were defined as lower heated wall by constant heat flux, cooled lateral walls, and insulated top wall. The three parameters elected to conduct the study are heater length (7 ≤
This paper presents an experimental and theoretical analysis to investigate the two-phase flow boiling heat transfer coefficient and pressure drop of the refrigerant R-134a in the evaporator test section of the refrigeration system under different operating conditions. The test conditions considered are, for heat flux (13.7-36.6) kW/m2, mass flux (52-105) kg/m2.s, vapor quality (0.2-1) and saturation temperature (-15 to -3.7) ˚C. Experiments were carried out using a test rig for a 310W capacity refrigeration system, which is designed and constructed in the current work. Investigating of the experimental results has revealed that, the enhancement in local heat trans
... Show MoreThe 2D resistivity imaging technique was applied in an engineering study for the investigation of subsurface weakness zones within University of Anbar, western Iraq. The survey was carried out using Dipole-dipole array with an n-factor of 6 and a-spacing values of 2 m and 5 m. The inverse models of the 2D electrical imaging clearly show the resistivity contrast between the anomalous parts of the weakness zones and the background resistivity distribution. The thickness and shape of the subsurface weakness zones were well defined from the 2D imaging using Dipole-dipole array of 2 m a-spacing. The thickness of the weakness zone ranges between 9.5 m to 11.5 m. Whereas the Dipole-dipole array with a-spacing of 5 m and n-factor of 6 allocated
... Show More