The most hazardous class of pharmaceuticals for soil and aquatic ecosystems are antibiotics, which include prescription medications and cancer treatments. Hospital effluents are usually produced by all parts of medical facilities, including hospitals. This study's specific goal was to provide a quick, affordable, and accurate analytical technique for determining the levels of amoxicillin, azithromycin, and penicillin in wastewater from Medical City, Al-Mahmudiya, and Al-Yarmouk hospitals (Iraq, Baghdad). An HPLC with a receptive ODS C18 column was used. It was equipped with UV and pulsed amperometric detectors with wavelengths of 230 nm and 210-240 nm, respectively. The correlation coefficients for each drug are greater than 0.9999, indicating that the approach is linear within the given range. It was evident that the limit of detection and limit of quantification for amoxicillin, azithromycin, and penicillin, respectively, were 0.103 µg/mL, 0.312 µg/mL, 0.069 µg/mL, and 0.211 µg/mL, and 0.086 µg/mL, 0.262 µg/mL. Ultimately, these results show that all wastewater samples from Medical City Hospital contain the three antibiotics amoxicillin, azithromycin, and penicillin. However, the Al-Mahmudiya sample had higher levels of penicillin and the Al-Yarmouk sample had lower levels of amoxicillin when compared to Medical City. The suggested method applies to a wide range of healthcare products used in a variety of effluent sources, including medical facilities and manufacturing environments. For citation: Jasim M. S. Jamur, Ala’a Abdullwahid Jasim, Wasan Abdulwahid Jasim High-performance liquid chromatography for the analysis of amoxicillin, azithromycin and penicillin in river hospital waste. ChemChemTech [Izv. Vyssh. Uchebn. Zaved. Khim. Khim. Tekhnol.]. 2026. V. 69. N 1. P. 127-134. DOI: 10.6060/ivkkt.20266901.7183.
Multimedia applications impose different QoS requirements (e.g., bounded end-to-end delay and jitter) and need an enhanced transport layer protocol that should handle packet loss, minimize errors, manage network congestion, and transmit efficiently. Across an IP network, the transport layer protocol provides data transmission and affects the QoS provided to the application on hand. The most common transport layer protocols used by Internet applications are TCP and UDP. There are also advanced transport layer protocols such as DCCP and TFRC. The authors evaluated the performance of UDP, DCCP, SCTP, and TFRC over wired networks for three traffic flows: data transmission, video streaming, and voice over IP. The evaluation criteria were thro
... Show MoreThe durability of asphalt pavement is associated with the properties and performance of the binder. This work-study intended to understand the impact of blending Styrene-Butadiene-Styrene (SBS) to conventional asphalt concrete mixtures and calculating the Optimum Asphalt Content (OAC) for conventional mixture also; compare the performance between SBS modified with the conventional mixture. Two different kinds of asphalt penetration grades, A.C. (40-50) and A.C. (60-70), were improved with 2.5 and 3.5% SBS polymer, respectively. Marshall properties were determined in this work. Optimum Asphalt Content (OAC) was 4.93 and 5.1% by weight of mixture for A.C. (40-50) and (60-70), respectively. Marshall properties results show an increasem
... Show MoreHighly Modified Asphalt (HiMA) binders have garnered significant attention due to their superior resistance to rutting, fatigue cracking, and thermal distress under heavy traffic loads and extreme environmental conditions. While elastomeric polymers such as Styrene- Butadiene-Styrene (SBS) have been extensively used in HiMA applications, the potential of plastomeric polymers, including Polyethylene (PE) and Ethylene Vinyl Acetate (EVA), remains largely unexplored. This study aims to evaluate the performance of reference binder (RB) modified with plastomeric HiMA asphalt in comparison to SBS-modified binders and determine the optimal polymer dosage for achieving an optimal balance between rutting resistance and fatigue durability. The experi
... Show MoreThere have been many advances in the solar chimney power plant since 1930 and the first pilot work was built in Spain (Manzanares) that produced 50 KW. The solar chimney power plant is considered of a clean power generation that needs to be investigated to enhance the performance by studying the effect of changing the area of passage of air to enhance the velocity towards the chimney to maximize design velocity. In this experimental and numerical study, the reduction area of solar collector was investigated. The reduction area that mean changing the height of glass cover from the absorbing plate (h1=3.8cm, h2=2.6cm and h3=1.28cm). The numerical study was performed using ANSYS Fluent software package (version 14.0) to solve go
... Show MoreThis paper introduces experimental results of eighteen simply supported reinforced concrete beams of cross sections ( ) and length 3000 mm to study the effect of lacing reinforcement on the performance of such beams under static and fatigue loads. Twelve reinforced concrete beams (two of them are casted with vertical shear reinforcement used as control beams) are tested under four points bending loading with displacement control technique and six laced reinforced concrete beams were exposed to high frequency (10 Hz) by fixing the fatigue load in each cycle. Three parameters are used in the designed beams, which are: lacing bar diameter (4mm, 6mm, and 8mm), lacing bar inclination angle to horizontal , and lacing steel rat
... Show MoreThermal performance of closed wet cooling tower has been investigated experimentally and theoretically
in this work. The theoretical model based on heat and mass transfer equations and heat and mass transfer balance equations which are established for steady state case. A new small indirect cooling tower was used for conducting experiments. The cooling capacity of cooling tower is 1 kW for an inlet water temperature of 38oC, a water mass velocity 2.3 kg/m2.s and an air wet bulb temperature of 26oC. This study investigates the relationship between saturation efficiency, cooling capacity and coefficient of performance of closed wet cooling tower versus different operating parameters such wet-bulb temperature, variable air-spray water fl
Abstract
The research study about the empowerment as an independent variable, in which details include (training and improvement, incentives, information sharing, trust, and delegation), has also focused on the performance of the service organization as a dependent variable in all dimensions which include (improve work efficiency, building the core competencies, focus on the beneficiary of the service, increasing the feeling of satisfaction of the employees, and the organizational support commitment). The research has been based on the opinions of a chosen sample of 75 service officers of the Ministry of Interior who work at the General Directorate of Traffic. The research problem has been identified by t
... Show More