Preferred Language
Articles
/
WRcoCpEBVTCNdQwC9pLJ
Implementation of a control and monitoring system for a cathodic protection cell to mitigate localized corrosion in fixed and mobile steel structures
...Show More Authors

The current study introduces a novel technique to handle electrochemical localized corrosion in certain limited regions rather than applying comprehensive cathodic protection (CP) treatment. An impressed current cathodic protection cell (ICCPC) was fabricated and firmly installed on the middle of a steel structure surface to deter localized corrosion in fixed or mobile steel structures. The designed ICCPC comprises three essential parts: an anode, a cathode, and an artificial electrolyte. The latter was developed to mimic the function of the natural electrolyte in CP. A proportional-integrated-derivative (PID) controller was designed to stabilize this potential below the ICCPC at a cathodic potential of −850 mV, which is crucial for protection efficacy. The controller of the protection system was designed to automatically activate the ICCPC when the environment of the steel structure is exposed to humidity. At a temperature range from 27 °C to 35 °C, the protection potential, current, and power showed an increase in percentage by 411 %, 688.74 %, and 2842.3 %, respectively when the humidity level rose from 10 % to 100 %. The intended spraying of sodium chloride (NaCl) solution on the structure at different concentrations from 1.5 % to 5 % showed excellent protection against corrosion, notable improvements in electrical conductivity, and reduction in resistance between the anode and cathode. The energy dispersive spectroscopy and scanning electron microscopy (SEM-EDS) analyses confirm effective corrosion inhibition under ICCPC coverage compared to unprotected areas. These tests revealed an absence of oxidation beneath the ICCPC compared with areas outside of its coverage. The areas outside of ICCPC protection showed a reduction in iron and carbon contents from 57.1 % to 47.0 % and 41.4 %–22.4 %, respectively, and an increase in oxygen from 1.6 % to 30.6 %.

Scopus Clarivate Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Tue Dec 01 2020
Journal Name
Baghdad Science Journal
Numerical Solution of Fractional Volterra-Fredholm Integro-Differential Equation Using Lagrange Polynomials
...Show More Authors

In this study, a new technique is considered for solving linear fractional Volterra-Fredholm integro-differential equations (LFVFIDE's) with fractional derivative qualified in the Caputo sense. The method is established in three types of Lagrange polynomials (LP’s), Original Lagrange polynomial (OLP), Barycentric Lagrange polynomial (BLP), and Modified Lagrange polynomial (MLP). General Algorithm is suggested and examples are included to get the best effectiveness, and implementation of these types. Also, as special case fractional differential equation is taken to evaluate the validity of the proposed method. Finally, a comparison between the proposed method and other methods are taken to present the effectiveness of the proposal meth

... Show More
View Publication Preview PDF
Scopus (10)
Crossref (3)
Scopus Clarivate Crossref
Publication Date
Sun Oct 01 2023
Journal Name
Nanostructures
Effect of Selenium Nanoparticles with Cress Extract on Polycystic Ovary Syndrome (PCOS)
...Show More Authors

Selenium is naturally present in the human body, animals, and plants, and is one of the important elements in their growth and maintenance. Recently, the nanoform of selenium has attracted attention due to its low toxicity and a high degree of adsorption compared to its organic and inorganic forms. The current study aimed to examine the effect of Cress leaves (Lepidium sativum L.) extract in combination with selenium nanoparticles in alleviating polycystic ovary syndrome in letrozole-induced PCOS in adult female rats. Nonthermal or cold plasma was used in the synthesis of selenium nanoparticles. Subsequently, the produced nanoparticles were identified, the 30 rats were divided into 6 equal groups, the first group was healthy (negative contr

... Show More
View Publication Preview PDF
Scopus (2)
Scopus
Publication Date
Wed Jan 01 2020
Journal Name
International Journal Of Mathematical Modelling And Numerical Optimisation
Reconstruction of an orthotropic thermal conductivity from non-local heat flux measurements
...Show More Authors

View Publication
Scopus (11)
Crossref (1)
Scopus Crossref
Publication Date
Sat Jun 10 2023
Journal Name
Buildings
Structural Performance of Internally Stiffened Double-Skinned Profiled Composite Walls with Openings
...Show More Authors

The double-skin profiled composite wall (DSPCW) system, filled with concrete material, is favorable in modern structures due to its high strength and ductility. Openings may be required within this composite wall (DSPCW) for various reasons, similar to a conventional bearing wall, which can lead to a reduction in bearing capacity. Therefore, to avoid changes in the geometry, materials, and thickness of this DSPCW wall, a new internally stiffening concept has been suggested by providing embedded cold-formed steel tube (CFST) columns. For this purpose, two full-scale DSPCW specimens were tested under static axial load, one of which was fabricated with a large opening size and stiffened with two octagonal CFST columns, while the other

... Show More
View Publication
Scopus (3)
Crossref (2)
Scopus Crossref
Publication Date
Tue Aug 01 2023
Journal Name
Civil Engineering Journal
Structural Strengthening of Insufficiently Designed Reinforced Concrete T-Beams using CFRP Composites
...Show More Authors

This study aims to compare the response of reinforced concrete (RC) T-beams strengthened with carbon fibre-reinforced polymer (CFRP) composite with that of non-strengthened control beams when subjected to monotonic two-point loading until failure for flexural once and shear again. The experimental programme tested eight RC T-beams, which included two reference beams without strengthening and six strengthened beams. The eight beams were divided into two main groups according to strengthening (flexural and shear). Experimental analysis was performed to study the effect of the CFRP laminate width in the flexural group and the spacing of CFRP U-wrap sheets in the shear group on the ultimate load capacity, load-strain relationship, and l

... Show More
View Publication
Scopus (8)
Crossref (3)
Scopus Crossref
Publication Date
Mon Jun 19 2023
Journal Name
Journal Of Engineering
Structural Behavior of Reinforced Concrete Hollow Beams under Partial Uniformly Distributed Load
...Show More Authors

A Longitudinal opening is used to construct hollow core beam is a cast in site or precast or pre stressed concrete member with continuous voids provided to reduce weight, cost and, as a side benefit, to use for concealed electrical or mechanical runs. Primarily is used as floor beams or roof deck systems. This study investigate the behavior of six beams (solid or with opening) of dimension (length 1000 x height 180 x width120mm) simply support under partial uniformly distributed load, four of these beam contain long opening of varied section (40x40mm) or (80x40mm). The effect of vertical steel reinforcing, opening size and orientations are investigated to evaluate the response of beams. The experimental behavior based on load-deflection

... Show More
View Publication Preview PDF
Crossref (19)
Crossref
Publication Date
Sun Dec 01 2019
Journal Name
Baghdad Science Journal
Synthesis of Functionalized Silica from Rice Husks Containing C-I End Group
...Show More Authors

In this paper, we have extracted Silica from rice husk ash (RHA) by sodium hydroxide to produce sodium silicate. 3-(chloropropyl)triethoxysilane (CPTES) functionalized with sodium silicate via a sol-gel method in one pot synthesis to prepare RHACCl. Chloro group in compound RHACCl replacement in iodo group to prepere RHACI. The FT-IR clearly showed absorption band of C-I at 580 cm-1. Functionalized silica RHACI has high surface area (410 m2/g) and average pore diameter (3.8 nm) within mesoporous range. X-ray diffraction pattern showed that functionalized silica RHACI has amorphous phase .Thermogravemitric analysis (TGA) showed two decomposition stages and SEM morphology of RHACI showed that the particles have irregu

... Show More
View Publication Preview PDF
Scopus (17)
Crossref (14)
Scopus Clarivate Crossref
Publication Date
Wed Mar 01 2023
Journal Name
Journal Of Engineering
Producing Load Bearing Block Using LECA as Partial Replacement of Coarse Aggregate
...Show More Authors

The ability to produce load-bearing masonry units adopting ACI 211.1 mix design using (1:3.2:2.5) as (cement: fine aggregate: coarse aggregate) with slump range (25-50mm) which can conform (dimension, absorption, and compressive strength) within IQS 1077/1987 requirements type A was our main goal of the study. The ability to use low cement content (300 kg/m3) to handle our market price products since the most consumption in wall construction for low-cost buildings was encouraging. The use of (10 and 20%) of LECA as partial volume replacement of coarse aggregate to reduce the huge weight of masonry blocks can also be recommended. The types of production of the load-bearing masonry units were A and B for (

... Show More
View Publication Preview PDF
Scopus (3)
Crossref (1)
Scopus Crossref
Publication Date
Wed Aug 01 2018
Journal Name
Journal Of Colloid And Interface Science
Removal of monoethylene glycol from wastewater by using Zr-metal organic frameworks
...Show More Authors

View Publication
Scopus (46)
Crossref (49)
Scopus Clarivate Crossref
Publication Date
Thu Feb 28 2019
Journal Name
Journal Of Engineering
Improvement of Earth Canals Constructed on Gypseous Soil by Soil Cement Mixture
...Show More Authors

The gypseous soil may be one of the problems that face the engineers especially when it used as a foundation for hydraulic structures, roads, and other structures. Gypseous soil is strong soil and has good properties when it is dry, but the problem arises when building hydraulic installations or heavy buildings on this soil after wetting the water to the soil by raising the water table level from any source or from rainfall which leads to dissolve the gypsum content.

Cement-stabilized soil has been successfully used as a facing or lining for earth channel, highway embankments and drainage ditches to reduce the risk of erosion and collapsibility of soil. This study is deliberate the treatment of gypseous soil by u

... Show More
View Publication Preview PDF
Crossref (12)
Crossref