Preferred Language
Articles
/
VxjIYpUBVTCNdQwCii0D
In Vitro Influence of Low-Power Diode Laser Irradiation Time on Human Red Blood Cells
...Show More Authors

Objective: The present study investigates whether the exposure to low-power diode laser induces denaturation in red blood cell (RBC) membrane protein composition, and determines the irradiation time for when denaturation of membrane protein process begins. Background: A low-energy laser has been used extensively in medical applications. Several studies indicated significant positive effects of laser therapy on biological systems. In contrast, other studies reported that laser induced unwanted changes in cell structure and biological systems. The present work studied the effect of irradiation time of low-power diode laser on the structure of membrane proteins of human RBCs. Materials and methods: The RBC suspension was divided into five equal aliquots. One aliquot served as control. The remaining four aliquots were exposed to low-power diode laser (wave length = 650 nm, power = 50 mW) for 10, 20, 30, and 40 min, respectively. After each given time, the percentage of denatured RBCs was calculated in each sample as described later. Results: Irradiation of RBCs by this laser for 20 min did not cause any change in membrane protein composition. While increasing the irradiation time to 30 min caused denaturation of membrane proteins, resulting in the formation of cross-bonding in a considerable number of RBCs, and the percentage of denatured cells increased in a dose-dependent manner to the irradiation. Conclusions: It can be concluded that the effect of low-power diode laser on RBC membrane protein structure depends on irradiation time.

Scopus
View Publication
Publication Date
Sun Mar 02 2008
Journal Name
Baghdad Science Journal
He-Ne Laser Irradiation Encourages reparative processes After cartilage loss in New Zealand rabbits
...Show More Authors

Many therapeutic methods used to encourage reparative processes of cartilage and accelerate their healing such as drugs, magneto-laser and so on. Twenty four adult New Zealand rabbits used in this study. They were divided in to two groups; control and treaded with He –Ne laser. A square skin flap done on the medial aspect of both auricles followed by pealing a square piece of cartilage from the auricle then the flaps sutured .The site of the operation in the rabbits of the treated group were irradiated with He –Ne laser 5mw power for seven days began after the operation directly. 3 rabbits from each group used for collection of specimens for histopathological examination at the 1, 2, 4 & 6 weeks post the operation. Significant

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Jan 01 2006
Journal Name
Journal Of Cosmetic And Laser Therapy
Use of the pulsed infrared diode laser (904 nm) in the treatment of alopecia areata
...Show More Authors

View Publication
Scopus (49)
Crossref (55)
Scopus Crossref
Publication Date
Sun Mar 06 2011
Journal Name
Baghdad Science Journal
Stimulation of Hatching Efficiency in Capsulated Cysts of Artemia fransiscana Using 890 nm Diode Laser
...Show More Authors

Artemia fransiscana is one of the most important live food for commercial larval aquaculture. The aim of this study is to investigate the effects of 890 nm diode laser irradiation on Artemia capsulated cysts using (1-10) minutes exposure time, and 2.26x10-3 J/cm2 Fluence. The Artemia samples were obtained from two locations: Dyalaa and Basraa. After irradiation, hatching percentage (H %) and hatching efficiency(HE) of Artemia were measured after 24 and 48 hours of incubation. The results of the effect of laser light on the capsulated cysts from Dyalaa showed that the optimum dose for enhancing (H %) after 24 hours of incubation is using 10 minutes exposure time, while after 48 hours of incubation the (H %) enhancement can be achieved

... Show More
View Publication Preview PDF
Crossref
Publication Date
Thu Jun 30 2022
Journal Name
Iraqi Journal Of Laser
PDF Treatment of intraoral pyogenic granuloma with diode laser 810-980 nmarch
...Show More Authors

Background: Pyogenic granuloma is a hyperplastic benign tumor. The most common intra-oral site is marginal gingiva. It is often occurred in the second decade of life, it has a strong tendency to recur after simple excision.

The aim of study: to evaluate the therapeutic advantages of diode laser (810-980 nm) in intraoral Pyogenic granuloma management.

Materials and method: A total of 28 patients (14 men and 14 females) were enrolled in this study and had their pyogenic granuloma surgically removed using a diode laser. All of the patients were given local anesthetic and went through the identical surgical procedure (cartridge containing 1 percent lidocaine with epinephrine 1:

... Show More
View Publication Preview PDF
Publication Date
Fri Aug 20 2021
Journal Name
Iraqi Journal Of Laser
Can diode laser avoid pilonidal sinus excision by the conventional operation?
...Show More Authors

Background: Pilonidal sinus is a recurrence pathology that affects the gluteal area, cleft part of it.  It affects many parts but mainly the sacral area and may present with various forms; from the asymptomatic cyst to severe infection in a form of painful abscess or sinus. The treatment of pilonidal sinus ranges from observation with good hygiene to excision of the sinus left wide incision. Recurrence may follow the excisional procedure and may need more operations. Many conservative ways had been used for the management of the sinus; laser (phototherapy) is one kind that may use. this paper aims to test the efficiency of the laser (diode 980nm) in the treatment of the sinus. material:

... Show More
View Publication Preview PDF
Publication Date
Tue Feb 12 2019
Journal Name
Iraqi Journal Of Physics
Effect of laser energy and ablation time on the formation of aluminum nanoparticles by nanosecond laser ablation of aluminum target in ethanol
...Show More Authors

In this work we study the influence of the laser pulse energy and ablation time on the aluminum nanoparticles productivity during nanosecond laser ablation of bulk aluminum immersed in liquid.
Aluminum nanoparticles were synthesized by pulsed laser ablation of Al targets in ethanol for 3-8 minutes using the 1064 nm wavelength of a Nd:YAG laser with energies of 300-500 mJ per pulse.The laser energy was varied between 300 and 500 mJ/pulse, whereas the ablation time was set to 5 minutes. UV-Visible absorption spectra was used for the characterization and comparison of products.

View Publication Preview PDF
Crossref
Publication Date
Mon Apr 24 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Influence of Gamma Radiation on Some Optical Properties and Urbach Energy of (PMMA- Doped Red Methyl) Films
...Show More Authors

  We have studied the effect of gamma irradiation on the optical transmission, absorbance, absorption coefficient,  and Urbach energy for (PMMA- doped red methyl) film deposited by using solvent casting method .The optical transmission (T %) in the wavelength range (1901100 ) nm of films was measured , it was seen that all the parameters were affected by gamma irradiation.

View Publication Preview PDF
Publication Date
Sun Jun 04 2017
Journal Name
Baghdad Science Journal
Texture Analysis of smear of Leukemia Blood Cells after Exposing to Cold Plasma
...Show More Authors

Plasma physics and digital image processing technique (DIPT) were utilized in this research to show the effect of the cold plasma (plasma needle) on blood cells. The second order statistical features were used to study this effect. Different samples were used to reach the aim of this paper; the patients have leukemia and their leukocytes number was abnormal. By studying the results of statistical features (mean, variance, energy and entropy), it is concluded that the blood cells of the sample showed a good response to the cold plasma.

View Publication Preview PDF
Scopus (23)
Crossref (1)
Scopus Crossref
Publication Date
Sat Apr 01 2023
Journal Name
Baghdad Science Journal
Influence of Glow and Afterglow Times on the Discharge Current of Argon at Low Pressure
...Show More Authors

     An experimental investigation of the variation of argon discharge current with a glow and afterglow time intervals of a square discharge voltage was carried out at low pressure (6-11 mbar). The discharge was created between two circular metal electrodes of diameter (7.5 cm), separated horizontally by a distance (10 cm) at the two ends of a Pyrex cylindrical tube. A composite of two Gaussian functions has been suggested to fit and explain the variation graphs clearly. It is shown that the necessary times of glow and afterglow needed to attain a maximum discharge current are (70 us) and (60 us), respectively. The discharge current is observed to drop to the lowest value when the two times are serially longer than (85 us) and (72 u

... Show More
View Publication Preview PDF
Scopus Crossref
Publication Date
Thu Apr 17 2025
Journal Name
Journal Of Baghdad College Of Dentistry
Effect of zinc oxide nanoparticles on total salivary peroxidase activity of human saliva (In vitro study)
...Show More Authors

Background: The potential use of zinc oxide and other metal oxide nanoparticles in biomedical are gaining interest in the scientific and medical communities, largely due to the physical and chemical properties of these nanomaterials. The present work revealed the effect of zinc oxide nanoparticles (ZnONPs) on the total salivary peroxidase enzyme activity of human saliva in comparison to de-ionized water. Materials and methods: Forty eight unstimulated saliva samples were collected from dental students/University of Baghdad 18-22 years. Then measure the total salivary peroxidase activity first without any addition to human saliva as a control, second with dilution the saliva with de-ionized water, and third with zinc oxide nanoparticles in c

... Show More
View Publication Preview PDF