Water is a resource and a crucial aspect of living and surviving. In Iraq, the Tigris River is one of the most critical water sources. The present study aimed to provide an insight analysis of some water quality parameters including the microbial content of drinkable tap water and river water. Ten Water samples (T1- T10) in triplicate were collected from sampling sites -Site I (Tap water) from home water taps, supplied by the Water Filtration Station/ Al Karama Project/ Al-Karkh> 10 from Site II (R1- R10)River water from Tigris River (around or near the Water Filtration Station/ Al Karama Project) every week (from September to half of November 2022), then were immediately placed in sterile bottles and transported to Microbiology lab for the analysis. Site I, turbidity was (0.7- 6) NTU. Free Chlorine availability was 0.5- 3.5 mg/L>CFU/ mL ranged from 0 to 40 in Total Plate Count (TPC);membrane filtration method (MFM) was unsatisfactory (T1, T8,T9), other samples were satisfactory. Site II, coliform result was 5200- 9200 CFU/ 100mL;Lauryl Tryptose broth (11000–49000) MPN/100mL,;Brilliant Green Bile broth (6900–17000 MPN/100mL); EC-MUG (E. coli medium with 4-methylumbelliferyl-β-D-glucuronide) was4900- 22000 MPN/100mL and EC-Broth was 4900- 22000 MPN/100mL. m-Endo Agar LES was +ve for all samples. All Tigris River water samples , were contaminated with coliform bacteria: E. coli, C. freundii, and Sphingomonas paucimobilis (sample R2) as non-coliform. Site I were drinkable and reliable, corresponding to Iraqi and WHO typical parameters, while Site II was under standardization.
Five species of Lactic acid bacteriawere isolated from raw milk, yoghurt, vegetables and pickles, Lactobacillus plantarum, Lactobacillus acidophilus, Lactobacillus brevis, Lactobacillus casei and Lactobacillus bulgaricus isolates were identified by 16S rRNA gene. Evaluate of antimicrobial activity against all the bacterial strains Staphylococcus aureus, Salmonella spp., Pseudomonas fluorescens, Escherichia coli, Bacillus cereus and Bacillus subtilis. It showed that bacteriocin of Lactic acid bacteriamore effective than supernatant of lactic acid bacteria, the results showed that isolatemost efficient isolate belonging to Lactobacillus brevis, the diameter of the inhibition of the bacteriocin of Lactobacillus brevis were 27.7, 26.3 and 25.1
... Show MoreThe alteration in the hydrological regime in Iraq and the anthropogenic increasing effect on water quality of a lotic ecosystems needs to continuous monitoring. This work is done to assess the water quality of Tigris River within Baghdad City. Five sites were selected along the river and ten physicochemical parameters and Overall Index of Pollution (OIP) were applied to assess the water quality for the period between November 2020 and May 2021, the studied period were divided into dry and wet seasons. These parameters were water temperature, pH, dissolved oxygen (DO), biological oxygen demand (BOD), total hardness, alkalinity, turbidity, total phosphorus, total nitrogen, electrical co
The bacterial contamination of lipsticks and face cream may become a great important matter in the medical laboratories. The present study was designed to determine the types of bacterial contamination in the face cream and lipsticks of undergraduate students. Also, the study aimed to determine the sensitivity of the isolated bacteria against many antibacterial agents. The study included 190 swabs samples from 190 face cream and lipsticks samples of the females’ students from five departments in the Medical Technology Institute, Almansour, Middle Technical University were collected in February 2018. The swab samples were collected with sterile condition and cultured on enriched Blood agar and MacConkey agar. Serial dilutions were made up
... Show MoreSource, sedimentation, coagulation, flocculation, filter, and tank are parts of a water treatment plant. As a result, some issues threaten the process and affect the drinking water quality, which is required to provide clean drinking water according to special standards and international and local specifications, determined by laboratory results from physical, chemical, and biological tests. In order to keep the water safe for drinking, it is necessary to analyze the risks and assess the pollution that occurs in every part of the plant. The method is carried out in a common way, which is monitoring through laboratory tests, and it is among the standards of the global and local health regulators
Source, sedimentation, coagulation, flocculation, filter, and tank are parts of a water treatment plant. As a result, some issues threaten the process and affect the drinking water quality, which is required to provide clean drinking water according to special standards and international and local specifications, determined by laboratory results from physical, chemical, and biological tests. In order to keep the water safe for drinking, it is necessary to analyze the risks and assess the pollution that occurs in every part of the plant. The method is carried out in a common way, which is monitoring through laboratory tests, and it is among the standards of the global and local health regulators
The concerns about water contaminants affect most developing countries bypassing rivers over them. The issue is challenging to introduce water quality within the allowed limits for drinking, industrial and agricultural purposes. In the present study, physical-chemical parameters measurements of water samples taken from eleven stations were collected during six months in 2020 through flow path along the whole length of Tigris River inside AL Kut city (center of Wassit government) were investigated for six parameters are total hardness TH, hydrogen ion pH, biological oxygen demand BOD5, total dissolved solids TDS, nitrate NO3, and sulfate SO4. The water quality analysis results were compared with the maximum allowable limit concentrat
... Show MoreIn this research, Artificial Neural Networks (ANNs) technique was applied in an attempt to predict the water levels and some of the water quality parameters at Tigris River in Wasit Government for five different sites. These predictions are useful in the planning, management, evaluation of the water resources in the area. Spatial data along a river system or area at different locations in a catchment area usually have missing measurements, hence an accurate prediction. model to fill these missing values is essential.
The selected sites for water quality data prediction were Sewera, Numania , Kut u/s, Kut d/s, Garaf observation sites. In these five sites models were built for prediction of the water level and water quality parameters.
The objective of this study is to evaluate the bacterial count and heavy metal concentration of river water on fish micronuclei. Fish and water samples are carried out in 1 May to 1 June 2013 from Tigris River. A total of fifty three fish sample are studied. The bacteriological quality of water showed that the total viable count is ranged from 150×103 to 352×103 cfu/ml and fecal coliform counts was 1250 cell/100ml during the study period. All the metals (Cu, Hg, Pb, and Zn) are within the normal limit, but Cd was slightly elevated in river water samples. The appearance of micronuclei in red blood cells of all fish species is detect , by recording a larger number of it, in ( Abu Alsomere , Hishne , Bannini Kaber al fam & Karkoor
... Show MoreAromatic hydrocarbons present in Iraqi national surface water were believed to be raised principally from combustion of various petroleum products, industrial processes and transport output and their precipitation on surface water.
Polycyclic aromatic hydrocarbons (PAHs) were included in the priority pollutant list due to their toxic and carcinogenic nature. The concern about water contamination and the consequent human exposure have encouraged the development of new methods for
PAHs detection and removal.
PAHs, the real contaminants of petroleum matter, were detected in selected sites along Tigris River within Baghdad City in summer and winter time, using Shimadzu high performance liquid chromatography (HPLC) system.
Analysi