Water is a resource and a crucial aspect of living and surviving. In Iraq, the Tigris River is one of the most critical water sources. The present study aimed to provide an insight analysis of some water quality parameters including the microbial content of drinkable tap water and river water. Ten Water samples (T1- T10) in triplicate were collected from sampling sites -Site I (Tap water) from home water taps, supplied by the Water Filtration Station/ Al Karama Project/ Al-Karkh> 10 from Site II (R1- R10)River water from Tigris River (around or near the Water Filtration Station/ Al Karama Project) every week (from September to half of November 2022), then were immediately placed in sterile bottles and transported to Microbiology lab for the analysis. Site I, turbidity was (0.7- 6) NTU. Free Chlorine availability was 0.5- 3.5 mg/L>CFU/ mL ranged from 0 to 40 in Total Plate Count (TPC);membrane filtration method (MFM) was unsatisfactory (T1, T8,T9), other samples were satisfactory. Site II, coliform result was 5200- 9200 CFU/ 100mL;Lauryl Tryptose broth (11000–49000) MPN/100mL,;Brilliant Green Bile broth (6900–17000 MPN/100mL); EC-MUG (E. coli medium with 4-methylumbelliferyl-β-D-glucuronide) was4900- 22000 MPN/100mL and EC-Broth was 4900- 22000 MPN/100mL. m-Endo Agar LES was +ve for all samples. All Tigris River water samples , were contaminated with coliform bacteria: E. coli, C. freundii, and Sphingomonas paucimobilis (sample R2) as non-coliform. Site I were drinkable and reliable, corresponding to Iraqi and WHO typical parameters, while Site II was under standardization.
Rates of zinc consumption during cathodic protection of a copper pipeline carrying saline water were measured by the loss in weight technique. The study of sacrificial anode cathodic protection of short copper tube using zinc strip extended axially in the pipe revealed that : (i) The increase of zinc consumption with time of exposure (1-3 h's) at different flow rates (turbulent flow) (300-600 l/hr) while the temperature , solution concentration and the pH were fixed at 20ºC, 3.5%wt NaCl, and pH=8 respectively in absence and presence of bacteria.(ii)Increase of zinc consumption with flow rates (300-600 l/hr) at different temperatures (10-40ºC) while solution concentration and time of exposure were fixed at 3.5 %wt NaCl and 3hr's respective
... Show MoreRates of zinc consumption during cathodic protection of a copper pipeline carrying saline water were measured by the loss in weight technique. The study of sacrificial anode cathodic protection of short copper tube using zinc strip extended axially in the pipe revealed that : (i) The increase of zinc consumption with time of exposure (1-3 h's) at different flow rates (turbulent flow) (300-600 l/hr) while the temperature , solution concentration and the pH were fixed at 20ºC, 3.5%wt NaCl, and pH=8 respectively in absence and presence of bacteria.(ii)Increase of zinc consumption with flow rates (300-600 l/hr) at different temperatures (10-40ºC) while solution concentration and time of exposure were fixed at 3.5 %wt NaCl and 3hr's respect
... Show MoreThe current research aims to adopt production quality decisions as the most important decisions , because they are accompanied by customer satisfaction through monitoring the quality of drinking water in iraq which reach through the pipeline network associated with water treatment projects of Tigris and Euphrates rivers. One of the indicators of quality control was the drawing of the C-chart by specifying the central line and the upper and lower limit of the control and the diagnosis of whether the production system as a whole within the scope of quality control or not and determine the strength and significance of the correlation between the quantities of water And actual needs for customers , the research has reached a number o
... Show MoreThe effect of chronic exposure to two different levels of cadmium chloride (CdCl2) 30 ppb and 40 ppb in drinking water for 12 weeks on thyroid function of mature male rabbits was studied. Eighteen mature male rabbits were randomly divided into three groups (each of six ) , control group (group I ): were offered ordinary tap water , and treated groups (II and III ) were offered tap water containing 30ppb and 40 ppb respectively for 12 weeks .Serum concentration of thyroxin (T4 ) and triiodothyronine (T3) were measured every six weeks ,as an index of thyroid function , further more , section of thyroid gland were prepared for histological studies. The results showed that chronic exposure of male rabbits
... Show MoreThe estimation of recharge to ground water is the important basics to improve the use of ground water with other available resources, and to save ground water resource from depletion, especially when using large quantity of ground water during a long time such as for agricultural purposes. Al-Wand River Basin in Iraq suffers from water shortage of its requirement of Blajo–Al-Wand Project, and to cover this shortage, the ground water plays a good role to overcome this problem. In this study, three methods were used to estimate the recharge and ground water storage for Al-Wand Basin, these methods are: Water Table Fluctuation (WTF), Water Balance of Climatic for Basin, and Water Table Balance for Basin. The results showe
... Show MoreThe presence of residual antibiotics in water results in the development of antibiotics resistant genes. The available wastewater treatment systems are not capable of removing such antibiotics from sewage. Thus, antibiotics need to be removed before the discharge of wastewater. Adsorption is among the promising techniques for the wastewater treatment to aid the removal of a wide range of organic and inorganic pollutants. The present work is a contribution to the search for an economical method for the removal of low concentrations of amoxicillin (AMX) from water by adsorption on water treatment residue, WTR, taken from a local drinking water facility. The chemical composition and the adsorptive characteristics of the material were first
... Show MoreSome physical and chemical characteristics of Jurf Al- Sakar drinking water plant in Babylon governorate have been studied. Seven locations for this plant were selected. These were the drinking water treatment plant source on Euphrates River before entering the plant, precipitation, filtration and collection tanks, and also after leaving the plant at distances of one meter, 4 and 8 km. The samples were collected bimonthly from October, 2002 to August, 2003. Some results match with the national and international standard characters while the other characters (Turbidity, total hardness, calcium, nitrate, phosphate and the biological oxygen demand values) were not match. The present study showed that drinking water treatment plant is undrinka
... Show MoreIn this study, the water treatment plants located on the Tigris River within Baghdad city were subjected to qualitative and quantitative assessments. Based on location, the plants from upstream to downstream are Al-Karkh, East Tigris, Al-Karamah, Al-Wathbah, Al-Wehdah, Al-Kadiseyah, Al-Dora, and Al-Rashid. Data from 2009 to 2020 on the turbidity, total dissolved solids, Alkalinity, hardness, chloride, calcium, and temperature were used in the qualitative assessment while data on the treated water production and population served were used in the quantitative assessment. The above Data was acquired from the Municipality of Baghdad. The turbidity was mainly used as a fair gauge to assess the performance of the water treatment plants in Baghda
... Show MoreDetermination of the concentrations of some inorganic elements (Fe, Co, Cu, Cr, Ni, Pb, Cd) by Flame Atomic Absorption Spectroscopy, Electrothermal Atomic Absorption Spectroscopy, and Inductively Coupled Plasma. and two dangerous organic pollutants (PAH and phenols) by GC and UV in the wastewater of Z.LTF Zafaraniya Leather tanning factory, W.BF Al-Waziriya Battery factory, Ba.WLS Al-Bayaa Wastewater Lifting Station, and some points of Tigris River in Baghdad city taking into consideration the sampling time Varying (two months) and setting the temperature during the drawing of the model. The results of the analysis revealed that the wastewater was contaminated with phenols, PAHs, and metals (Pb, Cd, Cr, Cu) at high rates that exceeded the p
... Show MoreSustainability including renewable energy and green power, is one of the important feature in recent years due to environmental constraints and the emission of CO2 from fossil fuel. Pressure retarded osmosis (PRO) process is considered one of the effective technology for power generation. This study assessed the application of pressure retarded osmosis to produce power from Tigris River water in Baghdad City, Iraq. Spiral wound TFC membrane was tested in the PRO process with different variables. The effect of different types of draw solutions (MgCl2, NaCl, Sodium Formate, KCl, Sodium Acetate), applied pressure (0 – 7 bar), and draw solution concentration (0.08 and 0.4 M) were tested in this work. The flux, recovery, and power density for
... Show More