Preferred Language
Articles
/
VhhDdJQBVTCNdQwCYxin
Study the Adhesion Capacity on abiotic surfaces by Acinetobacter baumannii isolated from drinking water.
...Show More Authors

Acinetobacter baumannii ability to form biofilm makes it to be opportunistic pathogen causing of nosocomial infections and to be good survivor in adverse environmental conditions including medical devices and hospital environments. Six isolates of A. baumannii were isolated from drinking water and tested to investigate biofilm formation capacity on three different type of abiotic surface, also several factors were examined such as hydrophobicity, PH and temperature. All A. baumannii isolates displayed a positive biofilm on congored aga test CRA (pigmented colonies with black color) and Christensen's test (adhesive layer of stained material to the inside surface of the tube).The obtained data of microbial adhesion to hydrocarbons assay (MATH) assay revealed that the percentage of all isolates ranged between (45-75%). Results of recent study revealed that optical density OD values were consistently higher on catheter than on that of the polystyrene and glass at any of the PH and temperature Temperature 37°C and PH 4 have greatest positive effect on biofilm formation process than other values, Current study may help in additional understanding of A. baumannii ability to form biofilm on abiotic surface which may be is used in medical devices' manufacturer and role of this in spreading of this pathogen in hospital environment.

Publication Date
Mon Jun 23 2025
Journal Name
Univesity Of Thi-qar Journal
Analysis of Heavy Metals in Water Samples of Euphrates River in Nasiriya City, Iraq
...Show More Authors

View Publication
Publication Date
Sun Nov 15 2020
Journal Name
Anbar Journal Of Engineering Sciences
Numerical Modelling and Experimental Investigation of Water Distribution in Stratified Soil Under Subsurface Trickle
...Show More Authors

View Publication
Crossref
Publication Date
Wed Apr 05 2023
Journal Name
Journal Of Engineering
A Developed Model for Selecting Optimum Locations of Water Harvesting Dams Using GIS Techniques
...Show More Authors

An integrated GIS-VBA (Geographical Information System – Visual Basic for Application), model is developed for selecting an optimum water harvesting dam location among an available locations in a watershed. The proposed model allows quick and precise estimation of an adopted weighted objective function for each selected location. In addition to that for each location, a different dam height is used as a nominee for optimum selection. The VBA model includes an optimization model with a weighted objective function that includes beneficiary items (positive) , such as the available storage , the dam height allowed by the site as an indicator for the potential of hydroelectric power generation , the rainfall rate as a source of water . In a

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sat Jan 01 2011
Journal Name
Journal Of Water Resource And Protection
Seasonal Variations of Some Ecological Parameters in Tigris River Water at Baghdad Region, Iraq
...Show More Authors

View Publication
Crossref (30)
Crossref
Publication Date
Fri Jan 01 2021
Journal Name
Aip Conference Proceedings
Radon concentrations assessment in tap water for different areas in Baghdad city using Rad7
...Show More Authors

View Publication
Scopus (1)
Scopus Crossref
Publication Date
Fri Feb 01 2019
Journal Name
Construction And Building Materials
Utilization of magnetic water in cementitious adhesive for near-surface mounted CFRP strengthening system
...Show More Authors

Cement-based adhesive (CBA) is used as a bonding agent in Carbon Fibre Reinforced Polymer (CFRP) applications as an alternative to epoxy-based adhesive due to the drawbacks of the epoxy system under severe service conditions which negatively affect the bond between the CFRP and strengthened elements. This paper reports the results of, an investigation carried out to develop two types of CBA using magnetized water (MW) for mixing and curing. Two magnetic devices (MD-I and MD-II), with different magnetic field strengths (9000 and 6000 Gauss) respectively, were employed for water magnetization. Different water flows with different water circulation times in the magnetizer were used for each device. Compressive and splitting tensile strength te

... Show More
Scopus (11)
Crossref (8)
Scopus Clarivate Crossref
Publication Date
Sun Jan 01 2017
Journal Name
Journal Of Engineering
Performance Enhancement of an Air Cooled Air Conditioner with Evaporative Water Mist Pre-cooling
...Show More Authors

The present paper deals with experimental investigation of the performance of air cooled split air conditioner, with evaporative water mist pre cooling to increase the cooling capacity and reduce the consumption power under hot and dry climate. This investigation considers how the performance can be enhanced by using water mist to pre-cool ambient air entering the condensers by adiabatic cooling process which depends on the ambient air wet bulb temperature; as well the condensing temperature and condensing pressure will be decreased accordingly. So the cooling capacity would be increased and consumption power would be decreased, consequently the energy ratio, EER would be improved. The performance of air cooled air conditioner with water

... Show More
View Publication Preview PDF
Publication Date
Thu Oct 20 2022
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Novel Method of Oil/Water Separation Using Composite of Polymethylacrylamide Hydrogel-Coated Metal Mesh
...Show More Authors

Different compositions of hydrogels composed of mathacrylamide homopolymer (60 and 90% of PMAM) were prepared using the free radical polymerization technique, with and without methylene bisacrylamide as crosslinker (0 and 3%). Several parameters and properties were studied to evaluate their performance as oil/water separators. Many parameters are used, such as residual oil in water, water recovery, separation time, hydrogels coated percentages, swelling parameters, mechanical properties, microscopic and photographic images, and scanning electron microscopy. The results showed that water recovery (87-97), Separation efficiency (96.2-99.6 %), separation time (6-9.5 min.), hydrogels coated percentages (18-23 %), water content (70-97 %), and

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Tue Dec 26 2017
Journal Name
Al-khwarizmi Engineering Journal
Corrosion Resistance of Synergistic Welding Process of Aluminium Alloy 6061 T6 in Sea Water
...Show More Authors

Abstract

 

This work involves studying corrosion resistance of AA 6061T6 butt welded joints using Two different welding processes, tungsten inert gas (TIG) and a solid state welding process known as friction stir welding, TIG welding process carried out by using Rolled sheet of thickness6mm to obtain a weld joint with dimension of (100, 50, 5) mm using ER4043 DE (Al Si5) as filler metal and argon as shielding gas, while Friction stir welding process carried out using CNC milling machine with a tool of rotational speed 1000 rpm and welding speed of 50mm/min to obtain the same butt joint dimensions. Also one of weld joint in the same dimensions subjected to synergistic weld

... Show More
View Publication Preview PDF
Publication Date
Thu Dec 30 2010
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
POLYVINYL ALCOHOL/POLYVINYL CHLORIDE (PVA/PVC) HOLLOW FIBER COMPOSITE NANOFILTRATION MEMBRANES FOR WATER TREATMENT
...Show More Authors

Two different polyvinyl alcohol/polyvinyl chloride (PVA/PVC) hollow fiber composite nanofiltration membranes were prepared after PVC hollow fiber membranes were coated using dip-coating method with PVA aqueous solution, which was composed of PVA, fatty alcohol polyoxyethylene ether (AEO9), and water [PVA/AEO9/water (4:0.5:95.5) wt%]. Effect of two different PVC hollow fiber immersion times in coating solution were studied. Cross-section, internal and external surfaces of the PVC hollow fibers and PVA/PVC composite nanofiltration membranes structures were characterized by scanning electron microscopy (SEM), pure water permeation flux and solutes rejection. It was found that, the coating layer thickness on the outer surface of the 19 wt% P

... Show More
View Publication Preview PDF