Preferred Language
Articles
/
VhflzJIBVTCNdQwCKsAT
The safety and efficacy of miniaturized percutaneous nephrolithotomy in children
...Show More Authors

To assess the use of miniaturized percutaneous nephrolithotomy (mini-PCNL) for renal stones in children, as well as its safety and efficacy. Seventy-seven patients with more than 15 mm renal stones whose age was less than 15 years were enrolled in this prospective case-controlled study at Al-Ramadi Teaching Hospital, Ar Razi Private Hospital, and Ghazi Al-Hariri Hospital for Surgical Specialties, Anbar and Baghdad, Iraq. The study was conducted from January 2020 to January 2024. The group mentioned above served as group A, and it was compared to the control group (group B), which consisted of 70 adult patients aged 18–60 years. Patients in both groups underwent mini-PCNL. Gender, stone size and location, time of operation, stone-free rate, hemoglobin drop, need for blood transfusion, postoperative fever, associated visceral injury, and need for further interventions such as extracorporeal shock wave lithotripsy or flexible ureteroscopy (ESWL or FURS) were compared in both groups. The age of patients in group A ranged from 8 months to 15 years with a mean (4.30 ± 3.16), while in group B ranged from 18 to 60 years with a mean (36.3 ± 12.0), p-value 0.001. There were no statistically significant differences regarding gender distribution, stone size, and location, p-value > 0.05. The stone-free rate was 87.01% for group A and 88.57% for group B, with no statistical difference, p-value 0.773. Hemoglobin drop was 1.096 ± 0.412 for group A and 1.195 ± 0.110 for group B, p-value 0.046. Blood transfusion was needed in one case in each group with no statistical difference, p-value 0.946. The need for ESWL was 3 cases in group A, and 2 cases in group B, with no statistical difference between the two groups, p-value 0.729. The need for FURS was 4 cases in group A and 3 cases in group B, p-value 0.796. Operative time was 30 to 125 min in group A and 34 to 129 min in group B, p-value 0.941. Postoperative fever was seen in 23 cases in group A and 21 cases in group B, p-value 0.986. Minor liver injury was seen was seen in one case in each group. The use of mini-PCNL for treating renal stones in children is safe and effective as it is associated with a relatively low rate of significant complications and achieves a high stone-free rate.

Scopus Clarivate Crossref
View Publication
Publication Date
Fri Nov 29 2019
Journal Name
Iraqi Journal Of Physics
Band Gap Characterization of Thermally Treated Hybrid Blend ZnPc/CdS Thin Films
...Show More Authors

Spin coating technique used to prepare ZnPc, CdS and ZnPc/CdS blend thin films, these films annealed at 423K for 1h, 2h and 3h. Optical behavior of these films were examined using UV-Vis. and PL. The absorption spectrum of ZnPc shows a decreasing in absorption with the increase of annealing time while CdS spectrum give a clearly absorption peak at~510 nm. Energy gap of ZnPc increases from 1.41 to 1.52 eV by increasing the annealing time. Eg of CdS decrease by increasing annealing time, from 2.3 eV to 2.2 eV. The intensities of the peaks obtained from PL spectra were strongly dependent on annealing time and confirmed the results obtained from UV-Vis. D.C. conductivity measurement showed that all the thin films have two differen

... Show More
View Publication Preview PDF
Crossref
Publication Date
Wed Feb 22 2023
Journal Name
Iraqi Journal Of Science
Determination of Destruction Levels Caused by Earthquakes Using Grip RADIUS 99 Program
...Show More Authors

The most universal and basic damages caused by an earthquakes are buildings damage and human casualties. A simplified method, the RADIUS 99 Tool is used to calculate seismic intensity (shaking) distribution, buildings damage, number of casualties and lifelines damage, due to assumed earthquake scenario. In this study, Al - Kadhmiya sector in Baghdad city was chosen for assessing seismic risk, for this purpose, this area was divided into mesh of 1*1 km2 cell size, and a scenario of (Manjil) earthquake (that struck Iran in 1990) was utilized with following earthquake magnitudes (5 and 7), with epicenter distance (3, 10 and 100 km), and depths (2 and 5 km). It was found that, the best soil types for constructions are those with medium and h

... Show More
View Publication Preview PDF
Publication Date
Fri Mar 30 2007
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Electrolytic preparation of Iron powder with particle Size Less than 106 pm
...Show More Authors

Avery large numbers of articles are made by powder metallurgical methods using electrolytically reduced metal powders. Iron powder is one of these powders which play an important role in this field. Its preparation by electrolytic method is economic in comparison with the traditional methods (Atomization and carbonyl processes).

An electrochemical cell consisting of two electrodes (stainless steel cathode and iron anode, 99.9%) was used to study the electrolytic preparation of iron powder with particle size less than 106µm directly as powde1y form. Ferrous sulphate electrolyte was used containing sodium chloride as a stabilizing agent. The produced powder was thoroughly washed with an acidified distilled water and absolute ethan

... Show More
View Publication Preview PDF
Publication Date
Thu Jul 28 2016
Journal Name
Computer And Information Science
Refinement for Ocular Ultrasound Images Quality by Utilizing Combination of Enhancement Techniques
...Show More Authors

Ultrasound has been used as a diagnostic modality for many intraocular diseases, due its safety, low cost, real time and wide availability. Unfortunately, ultrasound images suffer from speckle artifact that are tissue dependent. In this work, we will offer a method to reduce speckle noise and improve ultrasound image to raise the human diagnostic performance. This method combined undecimated wavelet transform with a wavelet coefficient mapping function: where UDWT used to eliminate the noise and a wavelet coefficient mapping function used to enhance the contrast of denoised images obtained from the first component. This methods can be used not only as a means for improving visual quality of medical images but also as a preprocessing

... Show More
View Publication Preview PDF
Crossref
Publication Date
Wed Dec 13 2017
Journal Name
Al-khwarizmi Engineering Journal
Shot Peening Time Effect on Corrosion Behaviors of Al Alloy 2024-T3
...Show More Authors

In this study many specimen s were prepared from 2024-T3 Aluminum alloy for corrosion test by the dimensions of (15*15*3) mm according to ASTM G71-31 and then subjected to shot peening process at different time (15, 30, 45) minutes using steel ball having a diameter of 2.75 mm and Rockwell Hardness of 55RC to induce compressive residual stress which were measured using X-Ray diffraction method, surface roughness and   hardness were tested before and after peening. Electrochemical corrosion test by Tafel extrapolation method was carried out in an environment of 3 .5% NaCl solutions (sea water) where Corrosion rate calculated using Tafle equation.

The obtained results show a favorable influence of SP treatment

... Show More
View Publication Preview PDF
Publication Date
Fri Jun 16 2023
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
Optimization of Bis-anthraquinones Production from Endophytic Fungi Diaporthe sp. GNBP-10
...Show More Authors

Bis-anthraquinones with a unique molecular backbone, (+)-2,2’-epicytoskyrin A (epi) and (+)-1,1′-bislunatin (bis), was produced by endophytic fungi Diaporthe sp GNBP-10 associated with Gambir plant (Uncaria gambier). Epi and bis possess robust antimicrobial activity toward various pathogens. This study focus on knowing the optimum condition of epi and bis production from Diaporthe sp GNBP-10. A series of culture media with various nutrient compositions was investigated in epi and bis production. The content of epi and bis was determined by measuring the area under the curve from TLC-densitometric (scanner) experiment. The linear regression analysis was then applied to obtain the results. The optimi

... Show More
View Publication Preview PDF
Scopus (1)
Crossref (1)
Scopus Crossref
Publication Date
Mon Jun 19 2023
Journal Name
Journal Of Engineering
Structural Behavior of Reinforced Concrete Hollow Beams under Partial Uniformly Distributed Load
...Show More Authors

A Longitudinal opening is used to construct hollow core beam is a cast in site or precast or pre stressed concrete member with continuous voids provided to reduce weight, cost and, as a side benefit, to use for concealed electrical or mechanical runs. Primarily is used as floor beams or roof deck systems. This study investigate the behavior of six beams (solid or with opening) of dimension (length 1000 x height 180 x width120mm) simply support under partial uniformly distributed load, four of these beam contain long opening of varied section (40x40mm) or (80x40mm). The effect of vertical steel reinforcing, opening size and orientations are investigated to evaluate the response of beams. The experimental behavior based on load-deflection

... Show More
View Publication Preview PDF
Crossref (15)
Crossref
Publication Date
Mon Dec 30 2024
Journal Name
Scientific Reports
Exploring dihydropyrimidone derivatives as modulators of carbohydrate catabolic enzyme to mitigate diabetes
...Show More Authors

View Publication
Scopus (2)
Crossref (2)
Scopus Clarivate Crossref
Publication Date
Thu Feb 01 2018
Journal Name
Applied Mathematical Modelling
Identification of a multi-dimensional space-dependent heat source from boundary data
...Show More Authors

View Publication
Scopus (16)
Crossref (10)
Scopus Clarivate Crossref
Publication Date
Wed Jan 01 2020
Journal Name
Journal Of Mechanical Engineering Research And Developments
Real-time control of robotic hand by human hand at low cost
...Show More Authors

Scopus (4)
Scopus