To assess the use of miniaturized percutaneous nephrolithotomy (mini-PCNL) for renal stones in children, as well as its safety and efficacy. Seventy-seven patients with more than 15 mm renal stones whose age was less than 15 years were enrolled in this prospective case-controlled study at Al-Ramadi Teaching Hospital, Ar Razi Private Hospital, and Ghazi Al-Hariri Hospital for Surgical Specialties, Anbar and Baghdad, Iraq. The study was conducted from January 2020 to January 2024. The group mentioned above served as group A, and it was compared to the control group (group B), which consisted of 70 adult patients aged 18–60 years. Patients in both groups underwent mini-PCNL. Gender, stone size and location, time of operation, stone-free rate, hemoglobin drop, need for blood transfusion, postoperative fever, associated visceral injury, and need for further interventions such as extracorporeal shock wave lithotripsy or flexible ureteroscopy (ESWL or FURS) were compared in both groups. The age of patients in group A ranged from 8 months to 15 years with a mean (4.30 ± 3.16), while in group B ranged from 18 to 60 years with a mean (36.3 ± 12.0), p-value 0.001. There were no statistically significant differences regarding gender distribution, stone size, and location, p-value > 0.05. The stone-free rate was 87.01% for group A and 88.57% for group B, with no statistical difference, p-value 0.773. Hemoglobin drop was 1.096 ± 0.412 for group A and 1.195 ± 0.110 for group B, p-value 0.046. Blood transfusion was needed in one case in each group with no statistical difference, p-value 0.946. The need for ESWL was 3 cases in group A, and 2 cases in group B, with no statistical difference between the two groups, p-value 0.729. The need for FURS was 4 cases in group A and 3 cases in group B, p-value 0.796. Operative time was 30 to 125 min in group A and 34 to 129 min in group B, p-value 0.941. Postoperative fever was seen in 23 cases in group A and 21 cases in group B, p-value 0.986. Minor liver injury was seen was seen in one case in each group. The use of mini-PCNL for treating renal stones in children is safe and effective as it is associated with a relatively low rate of significant complications and achieves a high stone-free rate.
Functionalized-multi wall carbon nanotubes (F-MWCNTs) and functionalized-single wall carbon nanotubes (F-SWCNTs) were well enhanced using CoO Nanoparticles. The sensor device consisted of a film of sensitive material (F-MWCNTs/CoONPs) and (F-SWCNTs/CoO NPs) deposited by drop- casting on an n-type porous silicon substrate. The two sensors perform high sensitivity to NO2 gas at room temperatures. The analysis indicated that the (F-MWCNTs/CoONPs) have a better performance than (F-SWCNTs/CoONPs). The F-SWCNTs/CoONPs gas sensor shows high sensitivity (19.1 %) at RT with response time 17 sec, while F-MWCNTs/CoONPs gas sensor show better sensitivity (39 %) at RT with response time 13 sec. The device shows a very reproducible sensor p
... Show MoreLet R be a commutative ring with non-zero identity element. For two fixed positive integers m and n. A right R-module M is called fully (m,n) -stable relative to ideal A of , if for each n-generated submodule of Mm and R-homomorphism . In this paper we give some characterization theorems and properties of fully (m,n) -stable modules relative to an ideal A of . which generalize the results of fully stable modules relative to an ideal A of R.
In this work, we calculate and analyze the photon emission from quark and anti-quark interaction during annihilation process using simple model depending on phenomenology of quantum chromodynamic theory (QCD). The parameters, which include the running strength coupling, temperature of the system and the critical temperature, carry information regarding photon emission and have a significant impact on the photons yield. The emission of photon from strange interaction with anti-strange is large sensitive to decreases or increases there running strength coupling. The photons emission increases with decreases running strength coupling and vice versa. We introduce the influence of critical temperature on the photon emission rate in o
... Show MoreThe coefficient of charge transfer at heterogeneous devices of Au metal with a well-known dyeis investigations using quantum model.Four different solvent are used to estimation the effective transition energy. The potential barrier at interface of Au and dye has been determined using effective transition energy and difference between the Fermi energy of Au metal and ionization energy of dye. A possible transfer mechanism cross the potential barrier dyeand coupling strength interaction between the electronic levels in systems of Au and is discussed.Differentdata of effective transition energy and potential barrier calculations suggest that solvent is more suitable to binds Au with dye.
Often phenomena suffer from disturbances in their data as well as the difficulty of formulation, especially with a lack of clarity in the response, or the large number of essential differences plaguing the experimental units that have been taking this data from them. Thus emerged the need to include an estimation method implicit rating of these experimental units using the method of discrimination or create blocks for each item of these experimental units in the hope of controlling their responses and make it more homogeneous. Because of the development in the field of computers and taking the principle of the integration of sciences it has been found that modern algorithms used in the field of Computer Science genetic algorithm or ant colo
... Show MoreThis paper introduces a Laplace-based modeling approach for the study of transient converter-grid interactions. The proposed approach is based on the development of two-port admittance models of converters and other components, combined with the use of numerical Laplace transforms. The application of a frequency domain method is aimed at the accurate and straightforward computation of transient system responses while preserving the wideband frequency characteristics of power components, such as those due to the use of high frequency semiconductive switches, electromagnetic interaction between inductive and capacitive components, as well as wave propagation and frequency dependence in transmission systems.
The calculation of the oil density is more complex due to a wide range of pressuresand temperatures, which are always determined by specific conditions, pressure andtemperature. Therefore, the calculations that depend on oil components are moreaccurate and easier in finding such kind of requirements. The analyses of twenty liveoil samples are utilized. The three parameters Peng Robinson equation of state istuned to get match between measured and calculated oil viscosity. The Lohrenz-Bray-Clark (LBC) viscosity calculation technique is adopted to calculate the viscosity of oilfrom the given composition, pressure and temperature for 20 samples. The tunedequation of state is used to generate oil viscosity values for a range of temperatu
... Show More