To assess the use of miniaturized percutaneous nephrolithotomy (mini-PCNL) for renal stones in children, as well as its safety and efficacy. Seventy-seven patients with more than 15 mm renal stones whose age was less than 15 years were enrolled in this prospective case-controlled study at Al-Ramadi Teaching Hospital, Ar Razi Private Hospital, and Ghazi Al-Hariri Hospital for Surgical Specialties, Anbar and Baghdad, Iraq. The study was conducted from January 2020 to January 2024. The group mentioned above served as group A, and it was compared to the control group (group B), which consisted of 70 adult patients aged 18–60 years. Patients in both groups underwent mini-PCNL. Gender, stone size and location, time of operation, stone-free rate, hemoglobin drop, need for blood transfusion, postoperative fever, associated visceral injury, and need for further interventions such as extracorporeal shock wave lithotripsy or flexible ureteroscopy (ESWL or FURS) were compared in both groups. The age of patients in group A ranged from 8 months to 15 years with a mean (4.30 ± 3.16), while in group B ranged from 18 to 60 years with a mean (36.3 ± 12.0), p-value 0.001. There were no statistically significant differences regarding gender distribution, stone size, and location, p-value > 0.05. The stone-free rate was 87.01% for group A and 88.57% for group B, with no statistical difference, p-value 0.773. Hemoglobin drop was 1.096 ± 0.412 for group A and 1.195 ± 0.110 for group B, p-value 0.046. Blood transfusion was needed in one case in each group with no statistical difference, p-value 0.946. The need for ESWL was 3 cases in group A, and 2 cases in group B, with no statistical difference between the two groups, p-value 0.729. The need for FURS was 4 cases in group A and 3 cases in group B, p-value 0.796. Operative time was 30 to 125 min in group A and 34 to 129 min in group B, p-value 0.941. Postoperative fever was seen in 23 cases in group A and 21 cases in group B, p-value 0.986. Minor liver injury was seen was seen in one case in each group. The use of mini-PCNL for treating renal stones in children is safe and effective as it is associated with a relatively low rate of significant complications and achieves a high stone-free rate.
Due to its association with hepatocellular carcinoma and being one of the ten most common malignancies worldwide, hepatitis C viral infection has become a severe public health concern. Therefore, establishing an accurate, reliable and sensitive diagnostic test for this infection is strongly advised. Real-time polymerase chain reaction (PCR) has been created to achieve this purpose. The current study was established to investigate the hepatitis C virus among Iraqi patients with chronic renal failure and to detect the virus immunologically by the fourth generation enzyme-linked immunosorbent assay technique and molecularly by real-time PCR. As a result, out of 50 patients with chronic renal failure undergoing dialysis, 39 patients tes
... Show MoreThe evacuated tube solar collector ETC is studied intensively and extensively by experimental and
theoretical works, in order to investigate its performance and enhancement of heat transfer, for Baghdad climate
from April 2011 till the end of March 2012. Experimental work is carried out on a well instrumented collector
consists of 16 evacuated tubes of aspect ratio 38.6 and thermally insulated tank of volume 112L. The relation
between convective heat transfer and natural circulation inside the tube is estimated, collector efficiency, effect of
tube tilt angles, incidence angle modifier, The solar heating system is investigated under different loads pattern (i.e
closed and open flow) to evaluate the heat loss coefficient
This study introduces a series of single and pile group model tests subjected to lateral loads in . multilayered sand from Karbala, Iraq. The aim of this study is to investigate: the performance of the pile groups subjected to lateral loads; in which the pile batter inclination angle is changed; the effect of pile spacing (s/d) ratio, the influence of using different number of piles and pile group configuration. Results revealed that the performance of single negative (Reverse) Battered piles with inclination of 10° and 20° show a gain of 32% and 76 % in the ultimate lateral capacity over the regular ones. For pile groups, the use of a combination of regular, negative and positive battered piles in
... Show MoreElectrochemical machining is one of the widely used non-conventional machining processes to machine complex and difficult shapes for electrically conducting materials, such as super alloys, Ti-alloys, alloy steel, tool steel and stainless steel. Use of optimal ECM process conditions can significantly reduce the ECM operating, tooling, and maintenance cost and can produce components with higher accuracy. This paper studies the effect of process parameters on surface roughness (Ra) and material removal rate (MRR), and the optimization of process conditions in ECM. Experiments were conducted based on Taguchi’s L9 orthogonal array (OA) with three process parameters viz. current, electrolyte concentration, and inter-electrode gap. Sig
... Show MoreThe present study conducted to study epipelic algae in the Tigris River within Baghdad city for one year from September 2011 to August 2012 due to the importance role of benthic algae in lotic ecosystems. Five sites have been chosen along the river. A total of 154 species of epipelic algae was recorded belongs to 45 genera, where Bacillariophyceae (Diatoms) was the dominant groups followed by Cyanophyceae and Chlorophyceae. The numbers of common types in three sites were 47 species. Bacillariophyceae accounted 88.31% of the total number of epipelic algae, followed by Cyanophyceae 7.14 % and Chlorophyceae 4.55%. A 85 species (29 genera) recorded in site 1, 103 species (34 genera) in site2, 112 species (35 genera) in site3, 96 species
... Show MoreA new, accurate, precise and economic two spectrophotometric methods for determination of Paracetamol (Par), Ibuprofen (Ibu), and Caffeine (Caf) were suggested. Those methods were the first and second ratio derivative spectrum using a double devisor. Par, Ibu, and Caf showed many useful peaks for their quantified determination. The validity of all analysis modes for determination of the three compounds, peak to baseline, peak area and peak to peak were according to ICH. The linearity of two methods was between 5 µg/ml as a lower concentration and 50 µg/ml as the highest concentration for three compounds. Recovery percentage was around 100% and relative standard deviation was less than 2.6%. The methods were applied successfully in the
... Show MoreBackground: Studies discussing the correlation between biochemical markers of bone turnover and the diagnosis of osteoporosis in postmenopausal Iraqi women are rare. This study is devoted to find out the significance of serum osteocalcin (OC) and osteopontin (OPN) levels with the incidence of osteoporosis and its major complication (fracture).Objectives: to investigate the significance of bone turnover biochemical markers; serum osteocalcin and serum osteopontin in evaluating osteoporosis for postmenopausal Iraqi women with and without history of vertebral fracture, as well as to explore the relationship of these markers with bone mineral density (BMD).Methods: Fifty seven postmenopausal women whose ages are fifty years old and over, cat
... Show MoreA simple, accurate and sensitive spectrophotometric way is used to determine Bisacodyl in pure and pharmaceutical preparations. The proposed method depends on using 2,4-Dinitrophenylhydrazine as chromogenic reagent . The method was based on the oxidative coupling reaction of Bisacodyl with 2,4-Dinitrophenylhydrazine with Sodium periodate in the presence of sodium hydroxide as alkaline media to form red water soluble dye product , that has a maximum absorption at ?max 522nm . Beer ,s law is obeyed in the concentration of (2.00–20.00) ?g.ml -1 .The molar absorptivity is (6505) L.mol-1.cm-1,a sandall sensitivity of(0.0555) ?g.cm-2), correlation coefficient of (0.9970) , Limitof detection (LOD) (0.0312 ?g.ml-1), limit of Quantitation (LOQ) (
... Show More