Antibiotics present the greatest threat to soil and aquatic ecosystems among the different therapeutic groups of medicines (which include prescription drugs and treatments for cancer). The strongest drugs, antibiotics, have been utilized to stop the growth of microorganisms or eradicate them. Using high-performance liquid chromatography technology with fluorescence detection, the amounts of levofloxacin and tetracycline in the wastewater from three hospitals (Medical City, Al-Kindi, and Al-Yarmouk) were determined. Levofloxacin and tetracycline were chosen in this study because they are the most important water pollutants. These antibiotic residues were separated and measured using a gradient elution technique on a reverse-phase C18 column. A combination of methanol and deionized water made up the mobile phase system. For a 20-minute analysis period, the detector's excitation and emission wavelengths were set to 310 and 420 nm, respectively. Cleaning the SPE cartridge came after the extraction using pH 4 citrate buffer. Excellent linear ties (R2 > 0.9998) were seen in the calibration curves for levofloxacin and tetracycline at concentrations between 10 and 40 µg/ml. The limits of detection and quantification for levofloxacin and tetracycline were determined to be 0.61 µg/ml, 2.04 µg/ml, and 0.46 µg/ml and 1.54 µg/ml, respectively. The analysis of residues of antibiotics in various wastewater samples was successfully applied using the suggested methodology. The findings demonstrate the presence of tetracycline and levofloxacin in all wastewater samples. However, Al-Kindi had greater concentrations of them than Medical City and Al-Yarmouk. The proposed technique can be applied to a range of medical products in different wastewater sources, such as hospitals and industrial settings. For citation: Ala’a Abdullwahid Jasim, Wasan Abdulwahid Jasim, Jasim M. S. Jamur HPLC method for the determination of some antibiotic residues in different hospitals wastewater in Baghdad city, Iraq. ChemChemTech [Izv. Vyssh. Uchebn. Zaved. Khim. Khim. Tekhnol.]. 2024. V. 67. N 6. P. 21-28. DOI: 10.6060/ivkkt.20246706.7035.
Thin films of zinc selenide ZnSe have been prepared by using thermal evaporation method in vacuum with different thickness (1000 – 4000) Ao and a deposited on glass substrate and studying some electrical properties including the determination of A.C conductivity and real, imaginary parts of dielectric constant and tangent of loss angle. The result shows that increasing value of A.C conductivity with increasing thickness and temperature, and increasing capacitance value with increasing the temperature and decrease with increasing frequency . Real and imaginary parts of dielectric constant and tangent of loss angle decrease with increasing frequency
Sn(II) complex of the type, [Sn(SMZ)2]Cl2 was synthesized by the interaction of Sulfamethoxazole ligand and Tin Chloride, the complex was confirmed on the basis of results of elemental analyses, FT-IR, UV-Vis, molar conductance (Ëm). The elemental analysis data, suggests the stoichiometry to be 1:2 (metal: ligand) and determination of the formula of a coordination a complex formed between the Sn(II) ion and the SMZ using Job’s method of continuous variations. The study of (Ëm), indicated the electrolytic nature type 1:2. The [Sn(SMZ)2]Cl2 was screened for antibacterial activity against Gram-ve (Escherichia coli and Gram+ve (Staphylococcus aureus) and (Candida albicans) antifungal. The IR spectral data suggested that the coordination sit
... Show MoreThe aim of the research is to study the comparison between (ARIMA) Auto Regressive Integrated Moving Average and(ANNs) Artificial Neural Networks models and to select the best one for prediction the monthly relative humidity values depending upon the standard errors between estimated and observe values . It has been noted that both can be used for estimation and the best on among is (ANNs) as the values (MAE,RMSE, R2) is )0.036816,0.0466,0.91) respectively for the best formula for model (ARIMA) (6,0,2)(6,0,1) whereas the values of estimates relative to model (ANNs) for the best formula (5,5,1) is (0.0109, 0.0139 ,0.991) respectively. so that model (ANNs) is superior than (ARIMA) in a such evaluation.
Objectives: To assess quality of health care for clients at outpatient consultancy clinics in Al-Hilla City Hospitals, and to find out significant differences between the clients' perspectives toward quality of health care dimensions and their demographic characteristics such as (residence, age, gender, level of education, and occupation ).
Methodology: A descriptive analytic study design was carried out at outpatient consultancy clinics of Al- Hilla city hospital (Al-Hilla and Al-Imam Al-Sadiq general teaching hospital) from April 10 th to June 15 th 2019. Non – probability (purposive) sample of 200 clients who were coming to the Outpatient Consultancy Clinics were selected. Data is collected through used of an assessment tools an
In this research, the water quality of the potable water network in
Al-Shuala Baghdad city were evaluated and compare them with the
Iraqi standards (IQS) for drinking water and World Health
Organization standards (WHO), then water quality index (WQI) were
calculator: pH, heavy metals (lead, cadmium and iron), chlorides,
total hardness, turbidity, dissolved oxygen, total dissolved solid and
electrical conductivity. Water samples are collected weekly during
the period from February 2015 to April 2015 from ten sites. Results
show that the chlorides, total dissolved solid and electrical
conductivity less than acceptable limit of standards, but total
hardness and heavy metals in some samples higher than acceptabl
The role of filamentous bacteria represented by Streptomycessp was studied as biological treatment for activated sludge AL- Restomia treatment unit in Baghdad city. The result shows reducing in phosphate concentration where apprise in started entrance the treatment unit 12.083 mg/L fast the unit stages reached to 8.426 mg /L where nitrate concentration apprises 3.59 mg/l and ending in 2.43 mg/L The concentration of ammonia apprises 1358 mg/L and reached to 140 mg/L. also the TDS concentration reduced from 1426 to 1203 mg/L where nutrient which represented (SO4, Mg, Ca, Na, K) reduced by range 30.883- 23.337 , 194- 121 , 440- 321 , 109.03- 101.53 and 16.85- 15.4mg/L respectively COD reduce from427.263- 82mg/L with absorbance0.018- 0.027
... Show MoreA method is developed for the determination of iron (III) in pharmaceutical preparations by coupling cloud point extraction (CPE) and UV-Vis spectrophotometry. The method is based on the reaction of Fe(III) with excess drug ciprofloxacin (CIPRO) in dilute H2SO4, forming a hydrophobic Fe(III)- CIPRO complex which can be extracted into a non-ionic surfactant Triton X-114, and iron ions are determined spectrophotometrically at absorption maximum of 437 nm. Several variables which impact on the extraction and determination of Fe (III) are optimized in order to maximize the extraction efficiency and improve the sensitivity of the method. The interferences study is also considered to check the accuracy of the procedure. The results hav
... Show MoreUltraviolet spectrophotometric studies for antibiotic (amino glycoside) derivatives including, Neomycin, Streptomycin, Gentamycin and Kanamycin with special reagents, which are benzoyl chloride; benzene sulfonyl chloride, toluenesulfonyl chloride and phthalic anhydride were made. Amino glycosides derivatives were followed through measurements of the ultraviolet absorbance (A) from which the absorptivity (ε) of the complexes was deduced and molar absorbances using Ultraviolet for products and calculate the number of reagents molecule that combine to amino glycosides.