Preferred Language
Articles
/
VRfJW5MBVTCNdQwCZNKg
Plasma Sclerostin Level in Multiple Myeloma
Background:

Multiple myeloma (MM) is a heterogenous plasma cell malignancy with various complications. Sclerostin is a Wingless-type (Wnt) inhibitor specifically expressed by osteocytes; it acts as a negative regulator of bone formation.

Objectives:

To assess plasma sclerostin level in MM patients and find its correlations with clinical and laboratory data, including osteolytic bone disease and international staging system (ISS).

Materials and Methods:

This cross-sectional study included 80 individuals: 40 newly diagnosed MM patients and 40 healthy adults. Patients were divided according to the presence of bone disease and ISS stage and were investigated for complete blood count, blood film and bone marrow (BM). Plasma levels of β2-microglobulin and sclerostin were measured using competitive and sandwich enzyme immunoassay techniques, respectively.

Results:

Sclerostin level was significantly increased in MM patients than control group (P < 0.001) and was significantly higher in those with osteolytic bone disease and/or pathological fractures than those without bone lytic lesions (P < 0.001). Patients with ISS stage III showed significantly higher sclerostin level than stages I and II (P = 0.003). High sclerostin levels were positively correlated with blood urea, serum creatinine, uric acid, and β2-microglobulin (P-values 0.034, <0.001, <0.018 and <0.001, respectively) and negatively with glomerular filtration rate (P = 0.001). No significant correlation was found with age, gender, hematological and other biochemical parameters.

Conclusions:

In newly diagnosed MM patients, the plasma sclerostin was significantly correlated with renal impairment. High levels of plasma sclerostin were also found in advanced disease stage and with the presence of significant bone disease.

Scopus Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Tue Jan 01 2019
Journal Name
Technologies And Materials For Renewable Energy, Environment And Sustainability: Tmrees19gr
The use of cold atmospheric plasma in pentostam enhancement as Leishmaniasis treatment in vitro

This study illustrates in vitro effect of cold atmospheric plasma (CAP) on the treatment of Leishmania. In addition, the study evaluated the effect of drug treatment (pentostam) and the combination treatment of pentostan and CAP at different doses and incubation time 24 h in order to assess the most effective treatment. The duration of the cold plasma doses was 1 min, 2 min and 3 min, while the pentostam doses were 2.5 µg/ml and 5 µg/ml. The combinations therapies included combining the three cold plasma doses with the pentostam doses to test 6 combinations of treated in vitro. The maximum growth inhibition was given by combination treated 46% and 44% for donovani and tropica leishamnia respectively; these results give an indi

... Show More
Scopus (9)
Crossref (9)
Scopus Clarivate Crossref
View Publication
Publication Date
Mon Nov 01 2010
Journal Name
Iraqi Journal Of Physics
Plasma Dynamics and Pulse Shape Rules in Laser Heating of Opaque Targets in Ai

A theoretical model is developed to determine time evolution of temperature at the surface of an opaque target placed in air for cases characterized by the formation of laser supported absorption waves (LSAW) plasmas. The model takes into account both plasma dynamics and time variation of incident laser pulse (i.e. pulse shape or profile).Shock tube relations were employed in formulating plasma dynamics over target surface. Gaussian function was chosen in formulating the pulse profile in the present modeling

View Publication Preview PDF
Publication Date
Thu Dec 06 2018
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
Comparing the Quality of Life among Patients with Relapsing Remitting Multiple Sclerosis in Iraq Using Different Disease Modifying Therapies

Multiple sclerosis (MS) is a chronic, inflammatory, immune mediated disease of the central nervous system, mostly affecting young adults with mean age of 30 years, twice as high in women compared to men. The etiology of MS is not fully elucidated. MS symptoms are directly related to demyelination and axonal loss, along with other psychological symptoms, can result in functional limitations, disability and reduced quality of life (QoL).  The QoL assessments in patients with a chronic disease may contribute to improving treatment and could even be of prognostic value. The goals  of this study were  to  compare the QoL of  Iraqi patients with relapsing remitting multiple sclerosis (RRMS),using three different diseas

... Show More
Scopus (5)
Scopus Crossref
View Publication Preview PDF
Publication Date
Sat Oct 01 2011
Journal Name
Journal Of Engineering
MEASUREMENT OF GROUND LEVEL OZONE IN SELECTIVE LOCATIONS IN BAGHDAD CITY

The ground level ozone concentration at different locations in Baghdad city was identified. Five
different sites have been chosen to identify the ground level ozone concentration. Al- Dora and Al-
Za'afarania were chosen as areas contained point source ( power plant station ) in addition to high traffic
load , while Al –Uma park, Aden square and Al-Mawal square were chosen as area contained heavy
traffic only (line source). The measurement focuses on spring and fall because these periods display
favorable meteorology to ozone formation. During the research period the maximum values (peaks) for
ground level ozone concentration were observed at fall: at Al-Za'afarania area 101ppb as an average, at
Al-Dora 87 ppb as a

... Show More
Crossref (1)
Crossref
View Publication Preview PDF
Publication Date
Tue Feb 01 2022
Journal Name
Iraqi Journal Of Science
Some physical properties of SiO2 laser induced plasma

In this work; Silicon dioxide (SiO2) plasma plume was prepared by laser induced plasma (LIP). The electron number density, plasma frequency and Debye length were calculated by reading the data of I-V curve of Langmuir probe which was used as a diagnostic method of measuring plasma properties. Pulsed Nd:YAG laser was used for measuring the electron number density of SiO2 plasma plume under vacuum environment with varying both vacuum pressure and axial distance from the target surface. Some physical properties of the plasma generated such as electron density, plasma frequency and Debye length have been measured experimentally and the effects of vacuum pressure and Langmuir probe distance from the target were studied on those variables. An

... Show More
View Publication Preview PDF
Publication Date
Wed Dec 01 2021
Journal Name
Baghdad Science Journal
New Spectral Range Generations from Laser-plasma Interaction

            High-intensity laser-produced plasma has been extensively investigated in many studies. In this demonstration, a new spectral range was observed in the resulted spectra from the laser-plasma interaction, which opens up new discussions for new light source generation. Moreover, the characterizations of plasma have been improved through the interaction process of laser-plasma. Three types of laser were incorporated in the measurements, continuous-wave CW He-Ne laser, CW diode green laser, pulse Nd: YAG laser. As the plasma system, DC glow discharge plasma under the vacuum chamber was considered in this research. The plasma spectral peaks were evaluated, where they refer to Nitrogen gas. The results indicated that the

... Show More
Scopus (5)
Crossref (1)
Scopus Clarivate Crossref
View Publication Preview PDF
Publication Date
Thu Jun 30 2022
Journal Name
Iraqi Journal Of Science
Spectroscopic Diagnosis of Arc Carbon and Magnesium Plasma

      This research aims to investigate parameters for magnesium (Mg)  carbon (C), and carbon/magnesium plasma produced by the exploding electrical wire (EEW) technique. In this work, C and Mg nanoparticles were synthesized. The plasma spectra with three different current values (50, 75 and 100A) were recorded using optical emission spectroscopy (OES). The plasma electron temperature (Te), electron density (ne), plasma frequency (fp), Debye length (ℷD), and Debye number (ND) provided by arc discharge plasma were  calculated. Boltzmann plots were  used to calculate the electron temperature (Te); electron density (ne) was calculated by Stark broadening . The results showed that the electron temperature and electron density increa

... Show More
Scopus (5)
Crossref (2)
Scopus Crossref
View Publication Preview PDF
Publication Date
Sun Mar 13 2011
Journal Name
Baghdad Science Journal
Extraction and Purification of albumin from Hunan plasma

This study includes adescription of Human serum Albumin by amodified using ion- exchange chromatography with manipulated comparison with cold ethanol precipitation method , It has been nticed that this procedure is superior orer the classical method . The Final yield by the new method 69.32% with purity of 83.42% compared with cohn which yield 60.30 % with purity of 80.7 % . The new method prored that it suitable for the pusi Fication of such material because it yield no precipitation material and it increases the Final yield of albumin solutions . • Human serum Albumin . • Albumin purification . • Ion – exchange chromatography . • Human plasma . • Albumin extraction .

Crossref
View Publication Preview PDF
Publication Date
Mon Feb 04 2019
Journal Name
Iraqi Journal Of Physics
Electrical, thermal and optical characteristics of plasma torch

Non thermal argon plasma needle at atmospheric pressure was constructed. The experimental set up was based on simple and low cost electric components that generate electrical field sufficiently high at the electrodes to ionize various gases which flow at atmospheric pressure. A high AC power supply was used with 9.6kV peak to peak and 33kHz frequency. The plasma was generated using two electrodes. The voltage and current discharge waveform were measured. The temperature of Ar gas plasma jet at different gas flow rate and distances from the plasma electrode was also recorded. It was found that the temperature increased with increasing frequency to reach the maximum value at 15 kHz, and that the current leading the voltage, which demonstra

... Show More
Crossref
View Publication Preview PDF
Publication Date
Fri Dec 01 2023
Journal Name
Iraqi Journal Of Physics
Characterization of Magnetized-Plasma System Induced by Laser

  This study investigated the effect of applying an external magnetic field on the characteristics of laser-induced plasma, such as its parameters plasma, magnetization properties, emission line intensities, and plasma coefficients, for plasma induced from zinc oxide: aluminum composite (ZO:AL) at an atomic ratio of 0.3 %. Plasma properties include magnetization and emission line intensities. The excitation was done by a pulsed laser of Nd:YAG with 400 mJ energy at atmospheric pressure. Both the electron temperature and number density were determined with the help of the Stark effect principle and the Boltzmann-Plot method. There was a rise in the amount of (ne) and (Te) that was produced

... Show More
Crossref
View Publication Preview PDF