Nowadays, energy demand continuously rises while energy stocks are dwindling. Using current resources more effectively is crucial for the world. A wide method to effectively utilize energy is to generate electricity using thermal gas turbines (GT). One of the most important problems that gas turbines suffer from is high ambient air temperature especially in summer. The current paper details the effects of ambient conditions on the performance of a gas turbine through energy audits taking into account the influence of ambient conditions on the specific heat capacity ( , isentropic exponent ( ) as well as the gas constant of air . A computer program was developed to examine the operation of a power plant at various ambient temperatures and relative humidities. The ambient temperatures ranged from 0 to 45 ºC, with relative humidities from 10 to 90%. The obtained results show that a GT operated at increased inlet air temperatures is characterized by lower net power and thermal efficiency. At higher inlet air temperatures, increased relative humidity has a slight positive impact on the GT cycle net power and its thermal efficiency. Net output power of the GT decreased from 93.3 MW at 15 °C to 70 MW at 45 °C. Its efficiency decreased from 32.32% at 5 °C to 28.3% at 30 °C. Although fuel consumption is reduced, the heat rate as well and the specific fuel consumption (SFC) are enhanced. SFC increased by 5.36% with a 10 °C temperature rise in temperature at a constant relative humidity. Therefore, use of a gas turbine with inlet air cooling and humidification is appropriate for improved GT efficiency.
Background: Spontaneous abortion means that a pregnancy is lost prior to viability, the loss of a fetus weighing less than 500 g, and the loss of an embryo or fetus at 20 weeks gestation or less (WHO, 2001). Glenville, (2001) has reported that suffering a miscarriage is one of the most devastating things that can happen to a woman, and to her husband. Many women conceive easily and are not emotionally or physically prepared for the shock of losing a baby. Objective: To know effects of spontaneous abortion upon physical status and spiritual beliefs , also find out the association between physical status and spiritual beliefs with study variable (demographic & reproductive). Methodology: A descriptive Analytical study was conducted on Non
... Show MoreObjective: The present study aims at identifying the dimensions behind juvenile delinquency, and to identify their
socio-demographic characteristics of gender, age, and type of delinquency.
Methodology: A descriptive study was conducted in correctional schools in Baghdad City to identify the
behavioral, psychological, and social dimensions contributed to juvenile delinquency. The study sample consisted
of (50) juvenile delinquents, of them, 27 males, and 23 females whose ages range from (12 - 20) years. Those
delinquents live in males’ correctional school in Al-Shalichia, and females’ correctional school in Al-Karradah, in
Baghdad City. The study sample was selected in purposively. The study questionnaire was design
Background: Spontaneous abortion means that a pregnancy is lost prior to viability, the loss of a fetus weighing less than 500 g, and the loss of an embryo or fetus at 20 weeks gestation or less (WHO, 2001). Glenville, (2001) has reported that suffering a miscarriage is one of the most devastating things that can happen to a woman, and to her husband. Many women conceive easily and are not emotionally or physically prepared for the shock of losing a baby. Objective: To know effects of spontaneous abortion upon physical status and spiritual beliefs , also find out the association between physical status and spi
This paper presents an efficient methodology to design modified evaporative air-cooler for winter air-conditioning in Baghdad city as well as using it for summer air-conditioning by adding a heating process after the humidification process. laboratory tests were performed on a direct evaporative cooler (DEC) followed by passing the air on hot water through heat exchanger placed in the coolers air duct exit. The tests were conducted on the 2nd of December /2011 when the ambient temperature was 8.1°C and the relative humidity was (68%). The air flow rate is assumed to vary between 0.069 to 0.209 kg/s with constant water flow rate of 0.03 kg/s in the heat exchanger. The performance is reported in terms of effectiveness of DEC, satura
... Show MoreAir-conditioning systems (ACs) are essential in hot and humid climates to ensure acceptable ambient air quality as well as thermal comfort for buildings users. It is essential to improve refrigeration system performance without increasing the effects of global warming potential (GWP) and ozone depletion potential (ODP). The main objective of this study is to evaluate the performance of an air conditioning system that operates with a liquid suction heat exchanger (LSHX) through implementing refrigerants with zero OPD and low GWP (i.e., R134a and R1234yf). Liquid suction heat exchanger (LSHX) was added to an automobile air conditioning system (AACS).When Liquid suction heat exchanger was added to the cycle, primary results indicated t
... Show MoreIn this research project, a tip-tilting angle of a photovoltaic solar cell was developed to increase generated electrical power output. An active, accurate, and simple dual-axis tracking system was designed by using an Arduino Uno microprocessor. The system consisted of two sections: software and apparatus (hardware). It was modified by using a group of light-dependent resistor sensors, and two DC servo motors were utilized to rotate the solar panel to a location with maximum sunlight. These components were arranged in a mechanical configuration with the gearbox. The three locations of the solar cell were chosen according to the tilt angle values, at zero angles, which included an optimal 33-degree angle for the Baghdad location and
... Show Morethe influence of permeability tensor upon drainage of anisotropic soils under ponded water and steady recharge (rainfall) is theoretically investigated. Tensorial permeability has led to the formulation of mixed type partial differential equations. Since there is no analytical solution to this problem, the formulation is therefore solved numerically by the method of finite elements. The finite element formulation is implemented into a computer model which can be applied to any problem of seepage under steady state
conditions. Two different example problems representing two different flow conditions under full anisotropy have been studied. Results of the model for the isotropic case were checked against exact mathematical solutions de
The dependence of the energy losses or the stopping power for the ion contribution in D- T hot plasma fuels upon the corresponding energies and the related penetrating factorare arrive by using by a theoretical approximation models. In this work we reach a compatible agreement between our results and the corresponding experimental results.
The world is keeping pace with evolution in all its fields as a result of scientists' pursuit of continuous scientific and technological development. This evolution included the sports field, which had a large space in the aspect of development and for all disciplines, Therefore, it's reflected today in what we see of records and advanced achievements in sporting events and activities. The development in the field of sports was the result of scientific research (Hussein and Jawad., 2022), where the interest in the training process has become one of the most important pillars of the development of achievement (Neamah and Altay., 2020). The shooting sport has also witnessed a remarkable development due to the diversity and development of its
... Show MoreAbstract. In this research, the uranium concentration in (16) water samples collected from some agricultural areas surrounded with AlTuwitha nuclear site in Baghdad-Iraq was measured by using a CR-39 detector. The concentration of uranium in this study was from (0.6 ± 0.33mg/l) to (2.51 ± 0.49 mg/l), and the weighted average for the concentrations (1.262 ± 0.402 mg/l). The results showed it is a concentration of uranium level in water samples studied is higher than the allowed limit recommended by WHO and ICRP.