Preferred Language
Articles
/
VEInd5oBMeyNPGM3r8yq
Determination of cefotaxime-sodium at nanoscale level by a microflow injection cell via measuring turbidity using five irradiation sources (WSLEDs) with a single solar cell
...Show More Authors

This work presents a completely new develop an analyzer, named NAG-5SX1-1D-SSP, that is simple, accurate, reproducible, and affordable for the determination of cefotaxime sodium (CFS) in both pure and pharmaceutical drugs. The analyzer was designed according to flow injection analysis, and conducted to turbidimetric measurements. Ammonium cerium nitrate was utilized as a precipitating agent. After optimizing the conditions, the analysis system exhibited a linear range of 0.008-27 mmol. L-1 (n=29), with a limit of detection of 439.3 ng/sample, a limit of quantification of 0.4805 mg/sample, and a correlation coefficient of 0.9988. The repeatability of the responses was assessed by performing six successive injections of CFS at concentrations of 12 and 23 mmol. L-1, resulting in a relative standard deviation of 0.136% and 0.112%, respectively. The accuracy of the proposed method was determined by calculating the recovery (Rec%) which ranged from 100.7% to 103.36%. To further evaluate the newly developed method, a classical method involving UV-spectrophotometry and turbidimetry was used as a reference. The data derived from the four techniques underwent analysis through a two-way analysis of variance (ANOVA). The suggested approach was effectively utilized for quantifying antibiotics in pharmaceutical compounds.

Scopus Crossref
View Publication
Publication Date
Sun Oct 01 2017
Journal Name
Journal Of The Faculty Of Medicine Baghdad
Measuring of Plasma Melatonin Level in Patients with Preeclampsia
...Show More Authors

Background: disturbed physiological rhythm of blood pressure in preeclampsia is a common finding. The role of oxidative stress in pathogenesis of preeclampsia is well accepted. Melatonin is a powerful free radical scavenger so it's rapidly consumed by enhanced reactive oxygen species in preeclampsia causing non-dipping in blood pressure.Objective: To evaluate the change in plasma melatonin levels in patients with preeclampsia and its relationship with blood pressure.Patients and methods: In this prospective case control study a total of 40 primigravidae pregnant women were recruited during the period of 11 months between August 2015 and August 2016 in Baghdad teaching hospital, medical city, Iraq, divided into two groups:First group

... Show More
View Publication
Crossref (1)
Crossref
Publication Date
Wed Aug 03 2022
Journal Name
Egyptian Journal Of Chemistry
A Novel Bio-electrochemical Cell with Rotating Cylinder Cathode for Cadmium Removal from Simulated Wastewater
...Show More Authors

View Publication
Scopus (3)
Scopus Clarivate Crossref
Publication Date
Fri Jul 21 2023
Journal Name
Journal Of Engineering
Simultanous Electricity Production and Wastewater Ttreatment in a Microbial Fuel Cell Inoculeted with Anaerobic Sludge
...Show More Authors

In order to reduce the environmental pollution associated with the conventional energy sources and to achieve the increased global energy demand, alterative and renewable sustainable energy sources need to be developed. Microbial fuel cells (MFCs) represent a bio-electrochemical innovative technology for pollution control and a simultaneous sustainable energy production from biodegradable, reduced compounds. This study mainly considers the performance of continuous up flow dual-chambers MFC
fueled with actual domestic wastewater and bio-catalyzed with anaerobic aged sludge obtained from an aged septic tank. The performance of MFCs was mainly evaluated in terms of COD reductions and electrical power output. Results revealed that the C

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Fri Mar 01 2024
Journal Name
Baghdad Science Journal
A Comparison between Ericson's Formulae Results and Experimental Data Using New Formulae of Single Particle Level Density
...Show More Authors

The partial level density PLD of pre-equilibrium reactions that are described by Ericson’s formula has been studied using different formulae of single particle level density . The parameter  was used from the equidistant spacing model (ESM) model and the non- equidistant spacing model (non-ESM) and another formula of  are derived from the relation between  and level density parameter . The formulae used to derive  are the Roher formula, Egidy formula, Yukawa formula, and Thomas –Fermi formula. The partial level density results that depend on  from the Thomas-Fermi formula show a good agreement with the experimental data.

View Publication Preview PDF
Scopus Crossref
Publication Date
Tue Sep 01 2015
Journal Name
European Academic Research
Developing Students` Achievement by Using Self –Observation as a Reflective Teaching Techniques in Conversation Classes at the University Level.
...Show More Authors

The present study deals with the effect of self -observation on EFL University students` achievement in conversation classes. The process of self-observation helps the teacher to understand one’s own actions and the reactions in the process of teaching. The sample of this study is EFL students in the third stage at the Department of English Language, morning studies, College of Education /Ibn-Rushd .The sample of the study consists of (84) students distributed on experimental group(A) includes (42) students, and (42) students as control group(B). In order to achieve the aim of the study ,and to gain a closer idea about the impact of reflective teaching technique(self-observation) on the students achievement in conversation classes, a chec

... Show More
View Publication
Publication Date
Tue Jan 01 2019
Journal Name
The Turkish Journal Of Endocrinology And Metabolism
Cell-free DNA as a Clinical Indicator in Maternal Blood
...Show More Authors

As many expensive and invasive procedures are used for the diagnosis or follow-up of clinical conditions, the measurement of cell-free DNA is a promising, noninvasive method, which considers using blood, follicular fluid, or seminal fluid. This method is used to determine chromosomal abnormalities, genetic disorders, and indicators of some diseases such as polycystic ovary syndrome, pre-eclampsia, and some malignancies. Cell-free DNA, which are DNA fragments outside the nucleus, originates from an apoptotic process. However, to be used as a marker for the previously mentioned diseases is still under investigation. We discuss some aspects of using cell-free DNA measurements as an indicator or marker for pathological conditions.

View Publication
Scopus (2)
Crossref (1)
Scopus Crossref
Publication Date
Thu Jul 11 2024
Journal Name
Maaen Journal For Medical Sciences
Pharmacological Supplements Efficacy in Management of chronic pain associated with Sickle Cell Disease: A narrative review
...Show More Authors

Sickle cell disease (SCD) is a hereditary ailment that can cause severe pain and suffering to people who are affected. However, with continued investment in research and treatment options, we can make progress towards improving the lives of those with SCD. Over 40% of patients experience painful vaso-occlusive crises (VOCs), so we must work towards finding solutions and providing support for those living with this condition, These episodes, a hallmark of SCD, significantly contribute to morbidity, mortality, and a diminished quality of life, while also incurring substantial healthcare costs. Chronic pain particularly affects older adolescents and adults with SCD, with over half reporting daily discomfort. Opioid-based analgesics, though sti

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Wed Apr 30 2025
Journal Name
Iraqi Journal Of Science
Determination of Cobalt(II) Ion in Various Selected Alloys via Utilizing Continous Flow Injection Analysis ((CFIA) (Nagham-Four Sources of White  Snow LED Arranged in Three Rows Corresponding to Three Detectors Analyzer) (NAG-4SX3-3D)) Analyzer at 0-180o Angle
...Show More Authors

The research study focuses on the efficient and accurate detection and determination of cobalt ions. The detection method involves the formation of brilliant green aggregates with calcium hexacyanoferrate in the presence of nitric acid. (Nagham-four sources of white snow light-emitting diodes arranged in three rows corresponding to three detectors) (The NAG-4SX3-3D Analyzer is an optical, chemical, electronic, and detection tool that receives a cumulative signal (no amplification is required). The total distance travelled is 760 mm with regard to YZ(mV) - tsec (dmm). It was selected for its precise calculation of the energy transducer profile. The linear range for measuring cobalt (II) ions is 0.05 to 20 mM. For concentrations of 5

... Show More
View Publication
Scopus (2)
Crossref (4)
Scopus Crossref
Publication Date
Sun Nov 01 2015
Journal Name
Karbala International Journal Of Modern Science
Batch and flow injection spectrophotometric methods for the determination of barbituric acid in aqueous samples via oxidative coupling with 4-aminoantipyrine
...Show More Authors

A batch and flow injection (FI) spectrophotometric methods are described for the determination of barbituric acid in aqueous and urine samples. The method is based on the oxidative coupling reaction of barbituric acid with 4-aminoantipyrine and potassium iodate to form purple water soluble stable product at λ 510 nm. Good linearity for both methods was obtained ranging from 2 to 60 μg mL−1, 5–100 μg mL−1 for batch and FI techniques, respectively. The limit of detection (signal/noise = 3) of 0.45 μg mL−1 for batch method and 0.48 μg mL−1 for FI analysis was obtained. The proposed methods were applied successfully for the determination of barbituric acid in tap water, river water, and urine samples with good recoveries of 99.92

... Show More
View Publication
Scopus (14)
Crossref (6)
Scopus Crossref
Publication Date
Sun Dec 09 2018
Journal Name
Baghdad Science Journal
A Comparative Study on the Electrical Characteristics of Generating Plasma by Using Different Target Sources
...Show More Authors

In this research, the electrical characteristics of glow discharge plasma were studied. Glow discharge plasma generated in a home-made DC magnetron sputtering system, and a DC-power supply of high voltage as input to the discharge electrodes were both utilized. The distance between two electrodes is 4cm. The gas used to produce plasma is argon gas which flows inside the chamber at a rate of 40 sccm. The influence of work function for different target materials (gold, copper, and silver), - 5cm in diameter and around 1mm thickness - different working pressures, and different applied voltages on electrical characteristics (discharge current, discharge potential, and Paschen’s curve) were studied. The results showed that the discharge cur

... Show More
View Publication Preview PDF
Scopus (21)
Crossref (14)
Scopus Clarivate Crossref