Preferred Language
Articles
/
VBfTXI8BVTCNdQwC7HOv
Downregulation of the Gene Expression of Efflux Pump Gene (acrA) and its Regulator (ramA) in Klebsiella pneumoniae by Quaternary Ammonium Compounds
...Show More Authors

Introduction: Biocides are commonly used for disinfection in a variety of contexts. They are generally used to avoid infection by controlling biofilm on medical equipment. However, the literature lacks information on the effect of biocide on efflux pump gene expression. Objective: To determine the influence of biocide on biofilm development and efflux pump acrA and ramA gene expression. Methodology: The microtiter plate method was used to identify biofilm development in 80 isolates of K. pneumoniae. The minimal inhibitory concentrations (MIC) of three biocides (quaternary ammonium compound (QAC), chlorohexidine digluconate, and chloroxylenol) were estimated. The effect of QAC on the intensity and viability of biofilms was investigated as well. Its influence on biofilm was evaluated using scanning electron microscopy. For each isolate, gene expression of the acrA and ramA was evaluated before and after treatment with the biocide (at ½MIC). Results: The study revealed that 60% of isolates formed moderate biofilms. Biofilms of all isolates were inhibited by QAC at high concentrations. Moreover, QAC at ½MIC downregulated the gene expression of the efflux pump gene (acrA) and its regulator (ramA). Conclusion: Biofilms of all isolates were prevented by QAC at high doses. Furthermore, QAC at ½MIC decreased the expression of the efflux pump gene (acrA) and its regulator (ramA).

Scopus Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Fri Jan 01 2016
Journal Name
Iraqi Journal Of Science
Land cover change detection of Baghdad city using multi-spectral remote sensing imagery
...Show More Authors

Publication Date
Wed Oct 26 2022
Journal Name
Research Journal Of Chemistry And Environment
Synthesis, Antioxidant ability and Docking study for new 4, 4'-((2-(Aryl)-1H-benzo [d] imidazole-1, 3 (2H)-diyl) bis (methylene)) diphenol
...Show More Authors

New series of 4,4'-((2-(Aryl)-1H-benzo[d]imidazole1,3(2H)-diyl)bis(methylene))Diphenol(3a-g) was successfully synthesized from cyclization of the reduction product of bis Schiff bases (2) with aryl aldehydes bearing phenolic hydroxyl in the presence of acetic acid. The structure of these compounds was identified from FT-IR, 1H NMR, 13C NMR and EIMs. The Antioxidant capability was screened by DPPH and FRAP assays. Both assays showed antioxidant capability more than BHT as well. Compounds 3b and 3c showed antioxidant capacity slightly less than ascorbic acid. The docking study for theses compound was carried out as III DNA polymerase inhibitor. The results of docking demonstrated that the increase in hinderances around phenolic hy

... Show More
Preview PDF
Publication Date
Wed Oct 05 2022
Journal Name
Research Journal Of Chemistry And Environment
Synthesis, Antioxidant ability and Docking study for new 4, 4'-((2-(Aryl)-1H-benzo [d] imidazole-1, 3 (2H)-diyl) bis (methylene)) diphenol
...Show More Authors

New series of 4, 4'-((2-(Aryl)-1H-benzo [d] imidazole-1, 3 (2H)-diyl) bis (methylene)) Diphenol (3a-g) was successfully synthesized from cyclization of the reduction product of bis Schiff bases (2) with aryl aldehydes bearing phenolic hydroxyl in the presence of acetic acid. The structure of these compounds was identified from FT-IR, 1H NMR, 13C NMR and EIMs. The Antioxidant capability was screened by DPPH and FRAP assays. Both assays showed antioxidant capability more than BHT as well. Compounds 3b and 3c showed antioxidant capacity slightly less than ascorbic acid. The docking study for theses compound was carried out as III DNA polymerase inhibitor. The results of docking demonstrated that the increase in hinderances around phenolic hydr

... Show More
Publication Date
Wed Dec 13 2017
Journal Name
Al-khwarizmi Engineering Journal
A Comparison Between Recursive Least-Squares (RLS) and Extended Recursive Least-Squares (E-RLS) for Tracking Multiple Fast Time Variation Rayleigh Fading Channel
...Show More Authors

In order to select the optimal tracking of fast time variation of multipath fast time variation Rayleigh fading channel, this paper focuses on the recursive least-squares (RLS) and Extended recursive least-squares (E-RLS) algorithms and reaches the conclusion that E-RLS is more feasible according to the comparison output of the simulation program from tracking performance and mean square error over five fast time variation of Rayleigh fading channels and more than one time (send/receive) reach to 100 times to make sure from efficiency of these algorithms.

View Publication Preview PDF
Publication Date
Wed Oct 31 2018
Journal Name
Al-kindy College Medical Journal
Peers Pressure And Families Smoking Habit Influence On Smoking Behavior among male Students attending Secondary Schools At second Al- Kurkh education Directorate /Baghdad.
...Show More Authors

Background:  There is a strong desire of adolescent to have a peer group and to be appreciated and also to become a member of this group which can affect one each other. There for; encourage, adapting,and imitating of friends and group consider as the main reasons behind starting of smoking among youngsters. Smoking habits in the family were found tobe acause of smoking pressure among adolescentas peer pressure. Smoking habit may be started before 18 years of age in most adult smokers.

Objectives: To study the effect of peer pressure and family smoking habiton the prevalence of smoking among secondary school students.

Type of the study:  A cross

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Mon Jan 01 2024
Journal Name
Journal Of Oral Medicine And Oral Surgery
Evaluating dental implant stability using three devices Osstell<sup>®</sup>, Periotest<sup>®</sup>, and AnyCheck<sup>®</sup>: a clinical study
...Show More Authors

Introduction: Implant stability is usually measured with resonance frequency analysis (RFA) and damping capacity assessment (DCA). This study aimed to measure primary and secondary stabilities using 3 devices that are based on these methods, namely; RFA (Osstell®) and DCA (Periotest® and AnyCheck®) to assess the correlations of the measurements obtained by these devices and the correlations between implant stability and insertion torque. Material and Methods: This observational prospective study included 35 dental implants. The implant stability was measured using the 3 devices. Mann–Whitney U

... Show More
View Publication
Crossref
Publication Date
Thu Aug 29 2024
Journal Name
European Journal Of Orthodontics
Poly-ether-ether-ketone (PEEK) versus dead-soft coaxial bonded retainers: a randomized clinical trial. Part 1. Stability, retainer failure, and participant satisfaction
...Show More Authors
Abstract<sec> <title>Background

Poly-ether-ether-ketone (PEEK) was introduced in dentistry as an alternative to metal alloys.

Objective

To assess the effectiveness of PEEK-fixed retainers in preserving the stability of mandibular anterior and participant satisfaction as compared to the Dead-soft coaxial fixed retainer (DSC).

Trial design

A single-centre, two-arm parallel groups

... Show More
View Publication
Scopus (1)
Scopus Clarivate Crossref
Publication Date
Thu Dec 01 2022
Journal Name
Structural Concrete
Enhancement of RC T‐beams toughness using laced stirrups reinforcement for blast response predictions
...Show More Authors

Publication Date
Wed Nov 01 2017
Journal Name
International Journal Of Greenhouse Gas Control
Wettability of nano-treated calcite/CO2 /brine systems: Implication for enhanced CO2 storage potential
...Show More Authors

Nanofluids are proven to be efficient agents for wettability alteration in subsurface applications including enhanced oil recovery (EOR). Nanofluids can also be used for CO2-storage applications where the CO2-wet rocks can be rendered strongly water-wet, however no attention has been given to this aspect in the past. Thus in this work we presents contact angle (θ) measurements for CO2/brine/calcite system as function of pressure (0.1 MPa, 5 MPa, 10 MPa, 15 MPa, and 20 MPa), temperature (23 °C, 50 °C and 70 °C), and salinity (0, 5, 10, 15, and 20% NaCl) before and after nano-treatment to address the wettability alteration efficiency. Moreover, the effect of treatment pressure and temperature, treatment fluid concentration (SiO2 wt%) and

... Show More
Publication Date
Sat Jan 01 2022
Journal Name
International Middle Eastern Simulation And Modelling Conference 2022, Mesm 2022,
MECHANICS OF COMPOSITE PLATE STRUCTURE REINFORCED WITH HYBRID NANO MATERIALS USING ARTIFICIAL NEURAL NETWORK
...Show More Authors

Scopus