A total of 20 raw milk samples were used as the fouling agent for evaluating the bacteriological effectiveness of cleaning and sanitizing of domestic milking equipment by using ozonated water at 0.5 ppm comparing to the warm water at 55! for 5 minutes respectively. The mean values of total aerobic bacteria, Coliform and E.coli that present on the plastic and stainless-steel containers after using the raw milk as fouling agent were 3.4×10-6 , 6.7x10-5 and 5.8×10-3 cfu/cm2 respectively , after cleaning the stainless steel containers by the ozonated water the mean values of total aerobic bacterial counts, Coliforms and E.coli bacteria were reduced to 1.2×10-6, 4.7×10-5 and 3.3×10-3 CFU/cm2 respectively. while after cleaning by the warm water were only reduced to 2.3x10-6, 2.7×10-5and 2.8×10-3 CFU/cm2 respectively . The mean values of total aerobic bacteria, coliform ,and E.coli counts/ cm2 after cleaning the plastic containers by the ozonated water were reduced to 1.4×10-6, 1.8×10-5 and 2.4×10- 3 CFU/cm2 respectively, while the mean values after cleaning by the warm water were reduced to 1.1×10-6, 1.7×10-5 and 2.3×10- 3 CFU/cm2 respectively .The mean values of total aerobic, Coliforms and E.coli bacteria after using both the Ozonating and warm water for both stainless steel and plastic containers were reduced to 4.2x10-5, 2.1x10-3, 1.6x10-2, 2.2x10-5, 5.1x10-3 and 1.4x10-2 CFU/cm2 respectively. The results of the current study showed that the independed either treatment by the ozonated or warm water not effectively reduced the number of the quality control bacteria because such reduction in bacterial population could not be enough to guarantee the safety of the home dairy containers, while the combined both treatments had a significant reduction in the population of the quality control bacteria. The effectiveness of cleaning and sanitization by the ozonated and warm water process may be depending on the initial count contaminated bacteria of raw milk, exposure time, kind of containers and both concentration of ozone and the heating temperature.
Background: Chronic hyperplastic candidiasis is the least common type of oral candidiasis. The diagnosis, long-term treatment, and prognosis of this potentially malignant oral condition are still currently unclear. Objective: the aim of this study is to analyze the demographic features and clinical characteristics of oral chronic hyperplastic candidiasis. Materials and Methods: A retrospective analysis was performed on blocks and case sheets of patients who were diagnosed with chronic hyperplastic candidiasis in the archives of Oral and Maxillofacial Pathology at the College of Dentistry/University of Baghdad. Demographic and clinical characteristics were analyzed. Results: twenty-one cases with chronic hyperplastic candidiasis were coll
... Show MoreLandsat-5 Thematic Mapper (TM) has been imaging the Earth since March 1984 and Landsat-7 Enhanced Thematic Mapper Plus (ETM+) was added to the series of Landsat instruments in April 1999. In this paper the two sensors are used to monitoring the agriculture condition and detection the changing in the area of plant covers, the stability and calibration of the ETM+ has been monitored extensively since launch although it is not monitored for many years, TM now has a similar system in place to monitor stability and calibration. By referring to statistical values for the classification process, the results indicated that the state of vegetation in 1990 was in the proportion of 42.8%, while this percentage rose to 52.5% for the same study area in
... Show MoreKey components estimated in Acol total plant leaves and the results were as follows plant Acol humidity 72%
This study aims to find the effect of water-cement ratio on the compressive strength of concrete by using ultrasonic pulse velocity test (UPVT). Over 230 standard cube specimens were used in this study, with dimensions of 150mm, and concrete cubes were cured in water at 20 °C. Also, the specimens used in the study were made of concrete with varied water-cement ratio contents from 0.48 to 0.59. The specimens were taken from Diyarbakir-Turkey concrete centers and tested at the structure and material science lab, civil engineering, faculty of engineering from Dicle University. The UPV measurement and compressive strength tests were carried out at the concrete age of 28 days. Their UPV and compressive strength ranged
... Show MoreNanoparticles of humic acid and iron oxide were impregnated on the inert sand to produce sorbent for treating groundwater contained of cadmium and copper ions by technology of permeable reactive barrier (PRB). Sewage sludge was the source of the humic acid to prepare the coated sand by humic acid—iron oxide (CSHAIO) sorbent; so, this work is consistent with sustainable development. For 10 mg/L metal concentration, batch tests at speed of 200 rpm signified that the removal efficiencies are greater than 90% at sorbent dosage 0.25 g/ 50 mL, pH 6 and contact time 1 h. The kinetic data was well described by the Pseudo first-order model indicating that physicosorption is the predominant mechanism. The maximum adsorption capacities (qmax) were c
... Show Moreتسعى تركيا ضمن سياساتها المائية ومنذ زمن بعيد وبأصرار على تنفيذ المزيد من بناء السدود والمشاريع التخزينية المائية على حوضي دجلة والفرات، الامر الذي يؤدي بالضرورة الى تناقص معدل الواردات المائية لنهري دجلة والفرات الداخلة للاراضي العراقية .وبالتالي التأثير على مقومات التنمية الزراعية العربية بشكل عام والتنمية الزراعية بالعراق بشكل خاص ومن ثم تهديد الامن الغذائي الوطني.
لذا فأن البحث يهد
... Show MoreTrickle irrigation is a system for supplying filtered water and fertilizer directly into the soil and water and it is allowed to dissipate under low pressure in an exact predetermined pattern. An equation to estimate the wetted area of unsaturated soil with water uptake by roots is simulated numerically using the HYDRUS-2D/3D software. In this paper, two soil types, which were different in saturated hydraulic conductivity were used with two types of crops tomato and corn, different values of emitter discharge and initial volumetric soil moisture content were assumed. It was assumed that the water uptake by roots was presented as a continuous sink function and it was introduced into Richard's equation in the unsaturated z
... Show More