Background: Complete denture wearers show lower levels of bite force than dentate subjects. This has a significant influence on their chewing efficiency. In this study an attempt was made to investigate the effect of the impression technique on the maximum bite force in complete denture wearers. Materials and methods: The patients selected for this research were 12 edentulous patients. Three different techniques for registering the final impression were made; the mucostatic, mucofunctional, and the selective pressure impression technique. Two sets of upper and lower denture bases and one set of upper and lower dentures were constructed for each subject. Intraoral and extraoral instruments and devices, as well as a computer program were used for measuring the maximum bite force. Results: The subjects without past experience with complete dentures were able to give higher levels of bite force with dentures or denture bases constructed from the mucofunctional impression technique, while those with previous dentures gave higher levels of bite force with the dentures or denture bases constructed from the selective pressure impression technique. Conclusions: It is recommended that dentures constructed from the mucofunctional impression technique be used for those subjects without previous experience with complete dentures, while for those with previous complete dentures the selective pressure impression technique should be used.
Critical buckling and natural frequencies behavior of laminated composite thin plates subjected to in-plane uniform load is obtained using classical laminated plate theory (CLPT). Analytical investigation is presented using Ritz- method for eigenvalue problems of buckling load solutions for laminated symmetric and anti-symmetric, angle and cross ply composite plate with different elastic supports along its edges. Equation of motion of the plate was derived using principle of virtual work and solved using modified Fourier displacement function that satisfies general edge conditions. Various numerical investigation were studied to exhibit a convergence and accuracy of the present solution for considering some design parameters such as edge
... Show MoreSchiff bases are versatile compounds synthesized from the condensation of primary amino compounds with aldehydes or ketones. The high thermal of many Schiff base and their complexes were useful attributes for their application as catalysts in reactions involving at high temperatures. This thermal behavior of Schiff bases and their complexes was evaluated by TGA/DTG and DTA curves with 10 mass losses related to dehydration and decomposition. This review summarizes the developments in the last decade for thermal analysis of Schiff bases. Therefore, synthesis of Schiff bases and their complexes are reviewe
At the last two decades , The environment has witnessed tremendous changes in many fields with the huge competition , various technological development and customer satisfaction , that are reflected in economic units a doption for lean production system.
Lean accounting that has appeared as a response for change occurred of economic units adoption for changes occurred of economic units adoption for lean production instead of wide production system , has devised new performance measures suitable for economic units adoption for lean ideas: and helping in providing suitable information about evaluating economic unit performance , these measures are divided into three levels , cell level,value flow level , a
... Show MoreBackground: This in vitro study evaluated the fracture resistance of weakened endodontically treated premolars with class II MOD cavities restored with different composite restorations (Low-shrinkage Filtek P90, nanohybrid Filtek Z250 XT and SDR bulk fill). The type and mode of fracture were also assessed for all the experimental groups. Materials and Method: Fifty human adult maxillary premolar teeth were selected for this study. Standardized extensive class II MOD cavities with endodontic treatment were prepared for all teeth, except those that were saved as intact control. The teeth were divided into five groups of ten teeth each (n=10): (Group 1) intact control group, (Group 2) unrestored teeth with endodontic treatment, (Group 3) resto
... Show MoreIn this study, new derivatives of Schiff bases of 2-thio-5-aryl1,3,4-oxadiazole have been synthesized. The structures of these derivatives were characterized from their melting points, infrared spectroscopy and elemental analysis. The Schiff bases derivatives were tested for inhibition of E-coli and were all found to be active.
In this study, new derivatives of Schiff bases of 2-thio-5-aryl- 1,3,4-oxadiazole have been synthesized. The structures of these derivatives were characterized from their melting points, infrared spectroscopy and elemental analysis. The Schiff bases derivatives were tested for inhibition of E-coli and were all found to be active.
Background: The use of Miswak, chewing sticks (salvadorapersica) can be traced back to Babylonians some 7000 years ago. It is commonly used throughout the world especially for the purpose of oral hygiene. Muslims are using as the religious view. Current study aimed to test the ability of aqueous siwak extract to increase the resistance of enamel surface against acid dissolution compared to sodium fluoride. Materials and Method: Twenty maxillary first premolars were treated with the selected solutions included two aqueous siwak extract concentration(5%,10%) and sodium fluoride(0.05%)as control positive for 2 minutes once daily for 20days interval, de ionized water was used as control negative. The concentration of the dissolved phosphorus i
... Show More