This study aims to enhance the RC5 algorithm to improve encryption and decryption speeds in devices with limited power and memory resources. These resource-constrained applications, which range in size from wearables and smart cards to microscopic sensors, frequently function in settings where traditional cryptographic techniques because of their high computational overhead and memory requirements are impracticable. The Enhanced RC5 (ERC5) algorithm integrates the PKCS#7 padding method to effectively adapt to various data sizes. Empirical investigation reveals significant improvements in encryption speed with ERC5, ranging from 50.90% to 64.18% for audio files and 46.97% to 56.84% for image files, depending on file size. A substantial improvement of 59.90% is observed for data files sized at 1500000kb. Partitioning larger files notably reduces encryption time, while smaller files experience marginal benefits. Certain file types benefit from both strategies. Evaluation metrics include encryption execution time and throughput, consistently demonstrating ERC5's superiority over the original RC5. Moreover, ERC5 exhibits reduced power consumption and heightened throughput, highlighting its multifaceted benefits in resource-constrained environments. ERC5 is developed and tested on various file types and sizes to evaluate encryption speed, power consumption, and throughput. ERC5 significantly improves encryption speed across different file types and sizes, with notable gains for audio, image, and large data files. While partitioning smaller files only slightly improves encryption time, larger files partitioning yields faster results. Future research could explore ERC5 optimizations for different computing environments, its integration into real-time encryption scenarios, and its impact on other cryptographic operations and security protocols.
Stream ciphers are an important class of encryption algorithms. There is a vast body of theoretical knowledge on stream ciphers, and various design principles for stream ciphers have been proposed and extensively analyzed. This paper presents a new method of stream cipher, that by segmenting the plaintext into number of register then any of them combined to any other by using combination logic circuit (And, OR, JK, NOT, XOR), then using variant register in length as a key which provides security enhancement against attacks and then compare the strength of this method with RSA by calculaing the time necessary to get the original text by using the genetic algorithm. And the way that ha
... Show MoreThe study focuses on assessment of the quality of some image enhancement methods which were implemented on renal X-ray images. The enhancement methods included Imadjust, Histogram Equalization (HE) and Contrast Limited Adaptive Histogram Equalization (CLAHE). The images qualities were calculated to compare input images with output images from these three enhancement techniques. An eight renal x-ray images are collected to perform these methods. Generally, the x-ray images are lack of contrast and low in radiation dosage. This lack of image quality can be amended by enhancement process. Three quality image factors were done to assess the resulted images involved (Naturalness Image Quality Evaluator (NIQE), Perception based Image Qual
... Show MorePublic spending represents the government’s financial leverage and has a significant impact on real and monetary economic variables, and one of these effects is the effect of public spending on the exchange rate as an important monetary variable for monetary policy, As we know that public spending in Iraq is financed from oil revenues sold in US dollars, and the Ministry of Finance converts the US dollar into Iraqi dinars to finance the government's need to spend within the requirements and obligations of the state's general budget, And converting the US dollar into Iraqi dinars has an impact on the parallel exchange market, even if there is a contractual exchange rate between the Ministry of Finance and the Central Bank of Iraq to
... Show MoreTwo molecular imprinted polymer (MIP) membranes for Levofloxacin (LEV) were prepared based on PVC matrix. The imprinted polymers were prepared by polymerization of styrene (STY) as monomer, N,N methylene di acrylamide as a cross linker ,benzoyl peroxide (BPO) as an initiator and levofloxacin as a template. Di methyl adepate (DMA) and acetophenone (AOPH) were used as plasticizers , the molecular imprinted membranes and the non molecular imprinted membranes were prepared. The slopes and detection limits of the liquid electrodes ranged from -21.96 – -19.38 mV/decade and 2×10-4M- 4×10-4M, and Its response time was around 1 minute, respectively. The liquid electrodes were packed with 0.1 M standar
... Show MoreThe advancements in Information and Communication Technology (ICT), within the previous decades, has significantly changed people’s transmit or store their information over the Internet or networks. So, one of the main challenges is to keep these information safe against attacks. Many researchers and institutions realized the importance and benefits of cryptography in achieving the efficiency and effectiveness of various aspects of secure communication.This work adopts a novel technique for secure data cryptosystem based on chaos theory. The proposed algorithm generate 2-Dimensional key matrix having the same dimensions of the original image that includes random numbers obtained from the 1-Dimensional logistic chaotic map for given con
... Show MoreThe development of technology used in computerized programs is considered on of the most important topics that is responsible for creating tools that can be used in the business environment, the audit profession is one of those professions that received this development. In order for this profession to be more effective, there must be a tool based on sound (correct) scientific basis that can be based upon to enhance the quality of auditing. The research also aims to propose a computerized program to plan the auditing process according to the methods appropriate to the working environment in the audit offices and companies in Iraq. The computerized program was applied to the research sample and the hypothesis of the research has been prov
... Show MoreThe adsorption isotherms and kinetic uptakes of CO2 were measured. Adsorption isotherms were measured at two temperatures 309 K and 333 K and over a pressure range of 1 to 7 bar. Experimental data of CO2 adsorption isotherms were modeled using Langmuir, Freundlich and Temkin. Based on coefficient of correlation it was found that Langmuir isotherm model was well suited with the experimental data of CO2 adsorption isotherms. In addition, Adsorption kinetic of CO2 mixture with N2 containing 10 % by volume CO2 and 90 % by volume N2 were determined in a temperature 36 °C and under the atmospheric pressure .When the flow rate was increased from
... Show MoreConstruction joints are stopping places in the process of placing concrete, and they are required because in many structures it is impractical to place concrete in one continuous operation. The amount of concrete that can be placed at one time is governed by the batching and mixing capacity and by the strength of the formwork. A good construction joint should provide adequate flexural and shear continuity through the interface.
In this study, the effect of location of construction joints on the performance of reinforced concrete structural elements is experimentally investigated.
Nineteen beam specimens with dimensions of 200×200×950 mm were tested. The variables investigated are the location of the construction joints
... Show MoreCadmium sulfide photodetector was fabricated. The CdS nano
powder has been prepared by a chemical method and deposited as a
thin film on both silicon and porous p- type silicon substrates by spin
coating technique. Structural, morphological, optical and electrical
properties of the prepared CdS nano powder are studied. The X-ray
analysis shows that the obtained powder is CdS with predominantly
hexagonal phase. The Hall measurements show that the nano powder
is n-type with carrier concentration of about (-5.4×1010) cm-3. The
response time of fabricated detector was measured by illuminating
the sample with visible radiation and its value was 5.25 msec. The
specific detectivity of the fabricated det