Preferred Language
Articles
/
UxeRfpMBVTCNdQwCP9SF
The Accuracy of Electrocardiographic Criteria for Predicting Left Ventricular Hypertrophy in adult Patients with Systemic Hypertension
...Show More Authors

ABSTRACT: BACKGROUND: Left ventricular hypertrophy is a significant risk factor for cardiovascular complications such as ischemic heart disease, heart failure, sudden death, atrial fibrillation, and stroke. A proper non-expensive tool is required for detection of this pathology. Different electrocardiographic (ECG) criteria were investigated; however, the results were conflicting regarding the accuracy of these criteria. OBJECTIVE: To assess the accuracy of three electrocardiographic criteria in diagnosis of left ventricular hypertrophy in adult patients with hypertension using echocardiography as a reference test. PATIENTS AND METHODS: This is a hospital-based cross sectional observational study which included 340 adult patients with a history of hypertension (240 patients with left ventricular hypertrophy and 100 patients without depending on Echocardiographic results). Three electrocardiographic criteria including Sokolow Lyon Voltage, Cornell voltage, and Cornell voltage duration were evaluated for their sensitivity and specificity in detection of left ventricular hypertrophy in those patients. RESULTS: Each of older ages (over 50 years) (OR= (OR=6.25, 95%CI=3.75-10.39, p<0.001), male gender (OR=0.58, 95% CI= 0.36-0.93, p= 0.018) and type 2 diabetes mellitus (OR=8.14, 95%CI= 4.04-16.41, p<0.001) were significantly associated with development of left ventricular hypertrophy in patients with hypertension. The sensitivity and specificity of Sokolow Lyon Voltage, Cornell voltage, and Cornell voltage duration were 17.5% and 96%; 13.33% and 97%; and 10% and 98%, respectively. CONCLUSION: Older ages, male gender, and type 2 diabetes mellitus can increase the risk of left ventricular hypertrophy in hypertensive patients. All the studied criteria have low sensitivity and high specificity in recognition of the left ventricular hypertrophy in patients with hypertension, with no advantage of definite criterion over the others.

Preview PDF
Quick Preview PDF
Publication Date
Sat Jan 01 2022
Journal Name
Materials Today: Proceedings
Experimental and theoretical investigations of seepage reduction through zoned earth dam material with special core
...Show More Authors

View Publication
Scopus (15)
Crossref (10)
Scopus Clarivate Crossref
Publication Date
Mon Jun 27 2022
Journal Name
Materials
Flexural Performance of Encased Pultruded GFRP I-Beam with High Strength Concrete under Static Loading
...Show More Authors

There is an interesting potential for the use of GFRP-pultruded profiles in hybrid GFRP-concrete structural elements, either for new constructions or for the rehabilitation of existing structures. This paper provides experimental and numerical investigations on the flexural performance of reinforced concrete (RC) specimens composite with encased pultruded GFRP I-sections. Five simply supported composite beams were tested in this experimental program to investigate the static flexural behavior of encased GFRP beams with high-strength concrete. Besides, the effect of using shear studs to improve the composite interaction between the GFRP beam and concrete as well as the effect of web stiffeners of GFRP were explored. Encasing the GFRP

... Show More
Scopus (23)
Crossref (23)
Scopus Clarivate Crossref
Publication Date
Tue Nov 13 2012
Journal Name
Wireless Personal Communications
Design and Implementation of a Scalable RFID-Based Attendance System with an Intelligent Scheduling Technique
...Show More Authors

View Publication
Scopus (17)
Crossref (7)
Scopus Clarivate Crossref
Publication Date
Wed Aug 05 2020
Journal Name
Advances In Civil Engineering
Strength compensation of deep beams with large web openings using carbon fiber–reinforced polymer sheets
...Show More Authors

This article presents the results of an experimental investigation of using carbon fiber–reinforced polymer sheets to enhance the behavior of reinforced concrete deep beams with large web openings in shear spans. A set of 18 specimens were fabricated and tested up to a failure to evaluate the structural performance in terms of cracking, deformation, and load-carrying capacity. All tested specimens were with 1500-mm length, 500-mm cross-sectional deep, and 150-mm wide. Parameters that studied were opening size, opening location, and the strengthening factor. Two deep beams were implemented as control specimens without opening and without strengthening. Eight deep beams were fabricated with openings but without strengthening, while

... Show More
Scopus (23)
Crossref (24)
Scopus Clarivate Crossref
Publication Date
Tue Jan 19 2021
Journal Name
Archives Of Civil And Mechanical Engineering
Push-out test of steel–concrete–steel composite sections with various core materials: behavioural study
...Show More Authors

Steel–concrete–steel (SCS) structural systems have economic and structural advantages over traditional reinforced concrete; thus, they have been widely used. The performance of concrete made from recycled rubber aggregate from scrap tires has been evaluated since the early 1990s. The use of rubberized concrete in structural construction remains necessary because of its high impact resistance, increases ductility, and produces a lightweight concrete; therefore, it adds such important properties to SCS members. In this research, the use of different concrete core materials in SCS was examined. Twelve SCS specimens were subjected to push-out monotonic loading for inspecting their mechanical performance. One specimen was constructed from co

... Show More
View Publication
Scopus (35)
Crossref (33)
Scopus Clarivate Crossref
Publication Date
Mon Jun 05 2023
Journal Name
Journal Of Engineering
Serviceability behavior of High Strength Concrete I-beams reinforced with Carbon Fiber Reinforced Polymer bars
...Show More Authors

Fiber Reinforced Polymer (FRP) bars are anisotropic in nature and have high tensile strength in the fiber direction. The use of High-Strength Concrete (HSC) allows for better use of the high-strength properties of FRP bars. The mechanical properties of FRP bars can yield to large crack widths and deflections. As a result, the design of concrete elements reinforced with FRP materials is often governed by the Serviceability Limit States (SLS). This study investigates the short-term serviceability behavior of FRP RC I-beams. Eight RC I-beams reinforced with carbon-FRP (CFRP) and four steel RC I-beams, for comparison purposes, were tested under two-point loading.
Deformations on the concrete and crack widths and spacing are measured and

... Show More
View Publication Preview PDF
Crossref (12)
Crossref
Publication Date
Thu Dec 01 2011
Journal Name
Journal Of Engineering
DESIGN, CONSTRUCTION AND TESTING OF LOW SPEED WIND TUNNEL WITH ITS MEASUREMENT AND INSPECTION DEVICES
...Show More Authors

A low speed open circuit wind tunnel has been designed, manufactured and constructed at the
Mechanical Engineering Department at Baghdad University - College of Engineering. The work is one of
the pioneer projects adapted by the R & D Office at the Iraqi MOHESR. The present paper describes the
first part of the work; that is the design calculations, simulation and construction. It will be followed by a
second part that describes testing and calibration of the tunnel. The proposed wind tunnel has a test
section with cross sectional area of (0.7 x 0.7 m2) and length of (1.5 m). The maximum speed is about (70
m/s) with empty test section. The contraction ratio is (8.16). Three screens are used to minimize flow
distu

... Show More
View Publication Preview PDF
Crossref (7)
Crossref
Publication Date
Wed Aug 05 2020
Journal Name
Advances In Structural Engineering
Strength compensation of deep beams with large web openings using carbon fiber–reinforced polymer sheets
...Show More Authors

This article presents the results of an experimental investigation of using carbon fiber–reinforced polymer sheets to enhance the behavior of reinforced concrete deep beams with large web openings in shear spans. A set of 18 specimens were fabricated and tested up to a failure to evaluate the structural performance in terms of cracking, deformation, and load-carrying capacity. All tested specimens were with 1500-mm length, 500-mm cross-sectional deep, and 150-mm wide. Parameters that studied were opening size, opening location, and the strengthening factor. Two deep beams were implemented as control specimens without opening and without strengthening. Eight deep beams were fabricated with openings but without strengthening, while

... Show More
View Publication
Crossref (24)
Crossref
Publication Date
Tue Feb 26 2019
Journal Name
Journal Of Accounting And Financial Studies ( Jafs )
Role of the General Dudget in the Achievement of Sustainable Development: دراسة تحليلية مقارنة للموازنة العامة العراقية
...Show More Authors

The traditional method adopted in the preparation of the general budget in Iraq is not consistent with developments in the size specification response and spending and the associated weakness in the size of the amounts earmarked for investment projects which could adversely affect future generations and not to enable them to continue the development, which requires talking to estimate the adoption of style public expenditure in the state budget and reduce waste and extravagant where and invest public revenues of the state in investment projects and preservation of the environment and natural resources in order to ensure the benefit of future generations system, according to the system serves to achieve the overwhelming majority of member

... Show More
View Publication Preview PDF
Crossref
Publication Date
Thu Jun 09 2016
Journal Name
Journal Of The College Of Basic Education
Study the effect of Thymus vulgaris on the weight of Liver and Kidneys in Albino male rats
...Show More Authors