Preferred Language
Articles
/
UhfLT5IBVTCNdQwCxavc
DEVELOPMENT OF A SPECTROPHOTOMETRIC DETERMINATION OF PREDNISOLONE IN DIFFERENT DOSAGE FORMS
...Show More Authors

A sensitive, accurate, and affordable colorimetric method was developed for assaying prednisolone (PRZ) in various medicinal forms. The procedure involves the oxidation of PRZ by ferric ions, followed by complexation of the resulting ferrous ions with ferricyanide to produce a greenish-blue product. Common complexation conditions were thoroughly investigated. The mole ratio of FeCl₃·6H₂O to K₃Fe(CN)₆ was 8:1. The proposed mechanism of complexation was suggested and considered. Various parameters were optimized, including the reduction of the colorimetric reaction temperature to 50°C and the duration of heating and analysis to 20-30 minutes. The calibration curve was linear over the range of 1-60 µg/mL. The limit of detection (LOD) and the limit of quantification (LOQ) were 0.5 μg/mL and 1 μg/mL, respectively. Spiking actual samples with standard PRZ showed recoveries within the 97.3-100.1% range. The method exhibited high precision, with an RSD% of less than 1.5%. Additionally, the study confirmed that common pharmaceutical excipients did not interfere. Real medicinal samples, including tablets, syrup, eye drops, and creams, were successfully examined for direct analysis of PRZ using the developed methodology, demonstrating its suitability for routine analysis of various PRZ-containing drug formulations.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Fri Apr 01 2016
Journal Name
Nurse Education Today
Diabetes knowledge of nurses in different countries: An integrative review
...Show More Authors

View Publication
Scopus (52)
Crossref (49)
Scopus Clarivate Crossref
Publication Date
Wed Sep 01 2010
Journal Name
Al-khwarizmi Engineering Journal
Corrosion Behavior of Ti-6Al-4V Alloy in Different Media
...Show More Authors

     In this work the corrosion behavior of Ti-6Al-4V alloy was studied by using galvanostatic measurements at room temperature in different media which includ sodium chloride (food salt), sodium tartrate (presence in jellies, margarine, and sausage casings,etc.), sodium oxalate (presence in fruits, vegetables,etc.), acetic acid (presence in vinegar), phosphoric acid (presence in drink), sodium carbonate (presence in 7up drink,etc.), and sodium hydroxide in order to compare.

     Corrosion parameters were interpreted in th

... Show More
View Publication Preview PDF
Publication Date
Fri Dec 01 2023
Journal Name
Iop Conference Series: Earth And Environmental Science
Survey of some Fish Species from Different Localities in Baghdad
...Show More Authors
Abstract<p>This study is concerned with a survey of seven species belonging to seven genera under two families and two orders found in some different areas of the Tigris River, especially since these areas have not been surveyed for a long time, and an attempt to identify the existing species at the present time after the recent water scarcity of the Tigris and Euphrates rivers and all water bodies interior of Iraq and the impact of this scarcity on the fish diversity found in some areas of the Tigris River in Baghdad.</p>
View Publication
Scopus (1)
Scopus Crossref
Publication Date
Wed Dec 31 2025
Journal Name
Basrah Journal Of Agricultural Sciences
Pedogenesis of Calcite and Dolomite Content in Different Iraqi Soils
...Show More Authors

Soil samples were tested for Calcite and Dolomite using XRD analysis. some Iraqi soils have low levels in Calcite that might approaches to zero, and that does not mean it has zero level of Carbonate because the decrease in a major compound of this group (carbonate) will be on the expense of the other compound. Besides, dolomitization is no less importance than Calcification in Iraqi soils where it was in recent or paleo occurrence of these minerals. There was a highly significant Pearson correlation between Calcite and Dolomite contents in soils (significant at 0.01 level) that shows that the increase of one component will be on the expense of the other component, and here is an evidence for the occurring of Dolomitization process i

... Show More
View Publication
Scopus Crossref
Publication Date
Wed Dec 14 2016
Journal Name
Journal Of Baghdad College Of Dentistry
Gingival Marginal Leakage of Different Tooth Colored Materials Combination as an Intermediate Layer in Class II Composite Restoration (A Comparative In Vitro Study)
...Show More Authors

Background: The aim of this in vitro study was to evaluate and compare the microleakage between Vertise Flow T M composite material and other conventional (Filtek Z250, riva light cure and SDR) composite materials when restoring CII mesial box only cavity at gingival margin through die penetration test Materials and methods: Forty maxillary first premolars were prepared with class II box design only cavities. Samples were divided into four groups of ten teeth according to material used: group I (FiltekZ250 only). Group II (SDR+FiltekZ250). Group III (Vertise Flow +FiltekZ250). Group IV (Riva light cure+ FiltekZ250). After 24 hrs. immersion in 2% in methylene blue, samples were sectioned and micro leakage was estimated. Results: None of the

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Fri Mar 30 2001
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Construction of Nomograms Describing the Effect of Different Variables on the Behavior of a KCl/Polymer Drilling Fluid
...Show More Authors

View Publication Preview PDF
Publication Date
Mon Jun 25 2018
Journal Name
Oriental Journal Of Chemistry
Advancement and Validation of new Derivatives Spectrophotometric Method for Individual and Simultaneous Estimation of Diclofenac Sodium and Nicotinamide
...Show More Authors

View Publication
Scopus (9)
Crossref (8)
Scopus Clarivate Crossref
Publication Date
Sun Jun 05 2016
Journal Name
Baghdad Science Journal
Determination of Water-Soluble Vitamins in Iraqi Honey Bee and Compare with Others Types by High –Performance Liquid Chromatography
...Show More Authors

High-performance liquid chromatographic methods are used for the determination of water-soluble vitamins with UV-Vis. Detector. A reversed-phase high-performance liquid chromatographic has been developed for determination of water-soluble vitamins. Identification of compounds was achieved by comparing their retention times and UV spectra with those of standards solution. Separation was performed on a C18 column, using an isocratic 30% (v/v) acetonitril in dionozed water as mobile phase at pH 3.5 and flow rate 1.0m/min. The method provides low detection and quantification limits, good linearity in a large concentration interval and good precision. The detection limits ranged from 0.01 to 0.025µg/ml. The accuracy of the method was

... Show More
View Publication Preview PDF
Crossref (4)
Crossref
Publication Date
Wed Jun 01 2016
Journal Name
Journal Of Economics And Administrative Sciences
The Role of SMEs in Economic Development in Jordan: The Case of Al Hassan Industrial Estate
...Show More Authors

This study aimed at highlighting the role of small and medium enterprises in bringing about economic development in Jordan. The study examined the impact of the number, size of investment and the number of jobs provided by these enterprises on the rate of growth in gross domestic product (GDP) as an indicator for economic development. To achieve its objectives, the study adopted descriptive and quantitative analysis. A linear multi regression model was developed with a growth rate of GDP as dependent variable and the number of institutions, size of investment, and the number of job opportunities as independent variables. The study concluded that each increase by one small or medium enterprise lead to an increase in the rate of gr

... Show More
View Publication Preview PDF
Crossref
Publication Date
Wed Apr 19 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Separation and determination of poly aromatic hydrocarbons in vegetables samples in Baghdad city using HPLC Technique
...Show More Authors

The Reversed Phase High Performance Liquid Chromatography (RP-HPLC) has been used for the separation of Poly aromatic hydrocarbons(PAHs) by using column Reprosil 100 C 18 which was found to be a suitable one for this purpose. The result showed that using mobile phase of (Acetonitrile-water) Reversed Phase HPLC , flow rate of (1.2 ml/min) , column temperature (30CËš) and wave length of (254nm), give a complete separation with a good resolution . The total separation time was less than 20 min. The result of the study showed that the vegetables of Baghdad city were polluted by poly aromatic hydrocarbons(PAHs) in different places where samples taken because of drainage of the heavy water ,industrial trash and trash of oil colanders. -

... Show More