A sensitive, accurate, and affordable colorimetric method was developed for assaying prednisolone (PRZ) in various medicinal forms. The procedure involves the oxidation of PRZ by ferric ions, followed by complexation of the resulting ferrous ions with ferricyanide to produce a greenish-blue product. Common complexation conditions were thoroughly investigated. The mole ratio of FeCl₃·6H₂O to K₃Fe(CN)₆ was 8:1. The proposed mechanism of complexation was suggested and considered. Various parameters were optimized, including the reduction of the colorimetric reaction temperature to 50°C and the duration of heating and analysis to 20-30 minutes. The calibration curve was linear over the range of 1-60 µg/mL. The limit of detection (LOD) and the limit of quantification (LOQ) were 0.5 μg/mL and 1 μg/mL, respectively. Spiking actual samples with standard PRZ showed recoveries within the 97.3-100.1% range. The method exhibited high precision, with an RSD% of less than 1.5%. Additionally, the study confirmed that common pharmaceutical excipients did not interfere. Real medicinal samples, including tablets, syrup, eye drops, and creams, were successfully examined for direct analysis of PRZ using the developed methodology, demonstrating its suitability for routine analysis of various PRZ-containing drug formulations.
Electronic banking services appeared as a result of laying the foundations for the application of electronic automation in the banking field, and despite the clear expansion in its adoption and implementation as an inevitable necessity imposed by international and national developments, its application was not ideal according to the level that was expected to occur after the abandonment of traditional banking services, which produced some risks Which is evident in the absence of a legal system, whether at the level of proving and authoritative electronic banking services such as electronic signature, Or at the level of protecting the confidentiality of these services and ensuring that they are not exp
... Show MoreThe research seeks to identify the effectiveness of a selective program in modifying irrational thinking that causes anger among an important class of societies in general. namely teachers. Specifically female teachers because of the pressures they suffer because of the nature of this profession. It may develop into anger outburst, which may cause irrational thinking arose as a result of the different situations they are going through. The sample of the program consisted of (12) teachers in Egypt, from different educational sectors. The researcher intended to clarify the emotion of anger and the irrational thoughts associated with it and the contribution of the selective counseling program in modifying those irrational thinking. This was
... Show MoreIn this paper, we made comparison among different parametric ,nonparametric and semiparametric estimators for partial linear regression model users parametric represented by ols and nonparametric methods represented by cubic smoothing spline estimator and Nadaraya-Watson estimator, we study three nonparametric regression models and samples sizes n=40,60,100,variances used σ2=0.5,1,1.5 the results for the first model show that N.W estimator for partial linear regression model(PLM) is the best followed the cubic smoothing spline estimator for (PLM),and the results of the second and the third model show that the best estimator is C.S.S.followed by N.W estimator for (PLM) ,the
... Show MoreThe Disi water samples were collected from different Disi aquifer wells in Jordan using a clean polyethylene container of 10-liter size. A hyper-pure germanium (HPGe) detector with high- resolution gamma-ray spectroscopy and a low background counting system was used for the identification of unknown gamma-rays emitting from radionuclides in the environmental samples. The ranges of specific activity concentrations of 226Ra and 228Ra in the Disi aquifer water were found to be from 0.302 ± 0.085 to 0.723 ± 0.207 and from 0.047 ± 0.010 to 0.525 ± 0.138 Bq L−1, with average values of 0.516 ± 0.090 and 0.287 ± 0.091 Bq L−1, respectively. The average combined radium (226Ra + 228Ra) activity and radium activity ratio (228Ra/226Ra) in Disi
... Show More