Preferred Language
Articles
/
UYaoU4YBIXToZYAL8IIJ
Thermal performance of a flat-plate solar collector using aqueous colloidal dispersions of graphene nanoplatelets with different specific surface areas
...Show More Authors

The effects of using aqueous nanofluids containing covalently functionalized graphene nanoplatelets with triethanolamine (TEA-GNPs) as novel working fluids on the thermal performance of a flat-plate solar collector (FPSC) have been investigated. Water-based nanofluids with weight concentrations of 0.025%, 0.05%, 0.075%, and 0.1% of TEA-GNPs with specific surface areas of 300, 500, and 750 m2/g were prepared. An experimental setup was designed and built and a simulation program using MATLAB was developed. Experimental tests were performed using inlet fluid temperatures of 30, 40, and 50 °C; flow rates of 0.6, 1.0, and 1.4 kg/min; and heat flux intensities of 600, 800, and 1000 W/m2. The FPSC’s efficiency increased as the flow rate and heat flux intensity increased, and decreased as inlet fluid temperature increased. When using nanofluids in the FPSC, the measured temperatures of absorber plate and tube wall decreased down to 3.35% and 3.51%, respectively, with the increase in weight concentration and specific surface area, while the efficiency increased up to 10.53% for 0.1- wt% TEA-GNPs nanofluid with specific surface area of 750 m2/g, in comparison with water. When using water as heat transfer fluid, very good agreement was obtained between the experimental and predicted values of absorber plate temperature, tube wall temperature, and collector’s efficiency with maximum differences of 3.02%, 3.19%, and 3.26%, respectively. While, when using nanofluids, higher differences were found, up to 4.74%, 4.7%, and 13.47% for TEA-GNPs nanofluid with specific surface area of 750 m2/g, respectively. Accordingly, the MATLAB code was capable of simulating the thermal performance of FPSCs utilizing nanofluids as their heat transfer fluids with acceptable accuracy. Values of performance index were all greater than 1, and increased as weight concentration increased up to 1.104 for 0.1- wt% TEA-GNPs nanofluid with specific surface area of 750 m2/g, implying higher positive effects on efficiency than negative effects on pressure drop. Accordingly, the investigated nanofluids can efficiently be used in FPSCs for enhanced energy efficiency, and the 0.1- wt% water-based TEA-GNPs nanofluid with specific surface area of 750 m2/g was comparatively the superior one.

Crossref
Publication Date
Thu Jun 30 2011
Journal Name
Al-khwarizmi Engineering Journal
Characterization of Delamination Effect on Free Vibration of Composite Laminates Plate Using High Order Shear Deformation Theory
...Show More Authors

 A dynamic analysis method has been developed to investigate and characterize embedded delamination on the dynamic response of composite laminated structures. A nonlinear finite element model for geometrically large amplitude free vibration intact plate and delamination plate analysis is presented using higher order shear deformation theory where the nonlinearity was introduced  in the Green-Lagrange sense. The governing equation of the vibrated plate were derived using the Variational approach. The effect of different orthotropicity ratio, boundary condition and delamination size on the non-dimenational fundamental frequency and frequency ratios of plate for different stacking sequences are studied. Finally th

... Show More
View Publication Preview PDF
Publication Date
Sun Jul 09 2023
Journal Name
Journal Of Engineering
An Investigation into Thermal Performance of Mist Water System and The Related Consumption Energy
...Show More Authors

Experimental tests were conducted to investigate the thermal performance (cooling effect) of water mist system consisting of 5μm volume median diameter droplets in reducing the heat gain entering a room through the roof and the west wall by reducing the outside surface temperature due to the evaporative cooling effect during the hot dry summer of Baghdad/Iraq. The test period
was Fifty one days during the months May, June, and July 2012. The single test day consists of 16 test hours starting from 8:00 am to 12:00 pm. The results showed a reduction range of 1.71 to 15.5℃ of the roof outside surface temperature and 21.3 to 76.6% reduction in the daily heat flux entering the room through the roof compared with the case of not using w

... Show More
View Publication Preview PDF
Crossref
Publication Date
Fri Jun 30 2017
Journal Name
Journal Of Engineering
Enhancing Performance of Self–Compacting Concrete with Internal Curing Using Thermostone Chips
...Show More Authors

This paper is devoted to investigate the effect of internal curing technique on the properties of self-compacting concrete (SCC). In this study, SCC is produced by using silica fume (SF) as partial replacement by weight of cement with percentage of (5%), sand is partially replaced by volume with saturated fine lightweight aggregate (LWA) which is thermostone chips as internal curing material in three percentages of (5%, 10% and 15%) for SCC, two external curing conditions water and air. The experimental work was divided into three parts: in the first part, the workability tests of fresh SCC were conducted. The second part included conducting compressive strength test and modulus of rupture test at ages of (7, 28 and 90). The third part i

... Show More
View Publication Preview PDF
Publication Date
Tue Oct 01 2019
Journal Name
Journal Of Aerosol Science
The influence of plate tilt on the transfer function of small plate differential mobility analyzers
...Show More Authors

View Publication
Scopus (2)
Crossref (1)
Scopus Clarivate Crossref
Publication Date
Wed Apr 06 2022
Journal Name
Journal Of Composites Science
Solar-Light-Driven Ag9(SiO4)2NO3 for Efficient Photocatalytic Bactericidal Performance
...Show More Authors

Photocatalytic materials are being investigated as effective bactericides due to their superior ability to inactivate a broad range of dangerous microbes. In this study, the following two types of bacteria were employed for bactericidal purposes: Gram-negative Escherichia coli (E. coli) and Gram-positive Staphylococcus aureus (S. aureus). The shape, crystal structure, element percentage, and optical properties of Ag9(SiO4)2NO3 were examined after it was successfully synthesized by a standard mixing and grinding processing route. Bactericidal efficiency was recorded at 100% by the following two types of light sources: solar and simulated light, with initial photocatalyst concentration of 2 µg/mL, and 97% and 95% of bactericidal acti

... Show More
View Publication Preview PDF
Scopus (2)
Crossref (2)
Scopus Clarivate Crossref
Publication Date
Tue Jun 28 2011
Journal Name
Iraqi Journal Of Pharmacy
Effects of different concentrations of aqueous green tea extract against methotrexate-induced nephrotoxicity in rats
...Show More Authors

View Publication
Crossref
Publication Date
Mon Jan 01 2018
Journal Name
Ndt & E International
Porosity evaluation of in-service thermal barrier coated turbine blades using a microwave nondestructive technique
...Show More Authors

View Publication
Scopus (17)
Crossref (18)
Scopus Clarivate Crossref
Publication Date
Sat Apr 01 2023
Journal Name
Alexandria Engineering Journal
Employing Sisko non-Newtonian model to investigate the thermal behavior of blood flow in a stenosis artery: Effects of heat flux, different severities of stenosis, and different radii of the artery
...Show More Authors

View Publication
Scopus (23)
Crossref (24)
Scopus Clarivate Crossref
Publication Date
Sat Jul 28 2018
Journal Name
Journal Of Engineering
Experimental and Numerical Study Effect of Using Nanofluids in Perforated Plate Fin Heat Sink for Electronics Cooling
...Show More Authors

An experimental and numerical investigation of the effect of using two types of nanofluids with suspending of (Al2O3 and CuO) nanoparticles in deionized water with a volume fraction of (0.1% vol.), in addition to use three types of fin plate configurations of (smooth, perforated, and dimple plate) to study the heat transfer enhancement characteristics of commercial fin plate heat sink for cooling computer processing unit. All experimental tests under simulated conditions by using heat flux heater element with input power range of (5, 16, 35, 70, and 100 W). The experimental parameters calculated are such as water and nanofluid as coolant with Reynolds number of (7000, 8000, 9400 and 11300); the air

... Show More
View Publication Preview PDF
Crossref
Publication Date
Mon Mar 29 2021
Journal Name
Journal Of Engineering
Numerical Simulation of Water Distribution with Uptake Root in Drip Irrigation using Different Soil Hydraulic Models
...Show More Authors

Surface drip irrigation is one of the most conservative irrigation techniques that help control providing water directly on the soil through the emitters. It can supply fertilizer and providing water directly to plant roots by drippers. One of the essential needs for trickle irrigation nowadays is to obtain more knowledge about the moisture pattern under the trickling source for various types of soil with various discharge levels with trickle irrigation. Simulation numerical using HYDRUS-2D software, version 2.04 was used to estimate an equation for the wetted area from a single surface drip irrigation in unsaturated soil is taking into account water uptake by roots. In this paper, using two soil types were used, namely

... Show More
View Publication Preview PDF
Crossref