Background: White spot lesions are esthetic problems caused by subsurface enamel demineralization that seen as white opacity. Aim of the study: This study aimed to evaluate and to compare the color change after the treatment of the white spot lesions with resin nϔtrton and micro abrasion. Materials and Methods: rtϔ white spot lesions were generated on 48 premolar teeth by the use of a demineralization solution. The teeth were randomly divided using the Diagnodent into three study groups (16 teeth for each group) depending on the depth of the induced lesions: outer enamel, inner enamel and outer dentine. Then each group was fatherly subdivided into two groups (8 teeth for each group) the ϔrst group was treated with resin nϔtrtonǡ while the second one was treated with micro abrasion. For each group, Spectrophotometric examination was performed at three points: baseline (T0), after producing the lesion (T1), and after the treatment (T2). Results: While the mean of ΔE between (T0-T1) showed a snϔ nt difference between the outer and the inner enamel, the outer enamel and the outer dentine, there was no snϔ nt difference between the inner enamel and the outer dentine. On the other hand, the mean of ΔE between (T1-T2) of the three layers of the lesions showed that there was no snϔ nt difference between all the layers when the resin nϔtrton was used. However, there was a snϔ nt difference when the micro abrasion was used. The ΔE between (T0-T2) shows no snϔ nt difference between the three layers of the lesions and between the two materials, (p>0.05). Conclusion: Results of the present study revealed that the deeper the white spot lesion the more the color difference it was, and the resin nϔtrts was excellent in improving the color of the lesion with the same effectiveness as the microabrsion was.
Precision is one of the main elements that control the quality of a geodetic network, which defines as the measure of the network efficiency in propagation of random errors. This research aims to solve ZOD and FOD problems for a geodetic network using Rosenbrock Method to optimize the geodetic networks by using MATLAB programming language, to find the optimal design of geodetic network with high precision. ZOD problem was applied to a case study network consists of 19 points and 58 designed distances with a priori deviation equal to 5mm, to determine the best points in the network to consider as control points. The results showed that P55 and P73 having the minimum ellipse of error and considered as control points. FOD problem was applie
... Show MoreThe current study deals with estimating the protein concentration and the effect of fish weight on protein concentration values in red and white muscles in two different regions ( R1 : Anterior region lies 2 cm behind the head and R2: posterior region lies 2cm from caudal fin (in two types of bony fish, namely common carp (Cyprinus carpio) and Nile tilapia (Oreochromis niloticus). Samples were collected from Karmat Ali river- north of Basrah between October 2019 and February 2020. The protein was extracted using protein extraction buffer, the current study show that the average of protein concentration in red muscles of Nile tilapia ranged between 7.74-7.4 mg / ml and ( 6.8-8.85 mg / ml) in R1 and R2 region re
... Show MoreAbstract. In this study, we shall research the fibrewise micro ideal topological spaces over Ḃ, as well as the relationship between fibrewise micro ideal topological spaces over Ḃ and fibrewise micro topological spaces over Ḃ. At first present introduces a novel notion from fibrewise micro ideal topological spaces over Ḃ, and differentiates it from fibrewise micro topological spaces over Ḃ. Some fundamental characteristics from these spaces are studied. Then show discussed the fibrewise micro ideal closed and micro ideal open topologies. Many propositions relating to these ideas are offered. In the next part will study defines and investigates novel conceptions from fibrewise micro ideal topological spaces over Ḃ, particularly f
... Show MoreBackground: evaluate the effects of three different intracoronal bleaching agents on the shear bond strengths (SBS) and failure site of stainless steel and monocrystalline (sapphire) orthodontic brackets bonded to endodontically treated teeth using light cured orthodontic adhesive in vitro. Materials and methods: Eighty extracted sound human upper first premolars were selected, endondontically treated and randomly divided equally (according to the type of the brackets used) into two main groups (n = 40 per group). Each main group were subdivided (according to the bleaching agent used) into four subgroups 10 teeth each; as following : control (un bleached) group, hydrogen peroxide group (Hp) 35%, carbamide peroxide group (CP) 37% group and s
... Show MoreBackground: Decalcification of surface enamel adjacent to fixed orthodontic appliances, in the form of white spot lesions, is a wide spread and familiar well-known side effect of orthodontic treatment. The present study was carried out to evaluate the effect of enamel protective agent (Clinpro white varnish) on shear and tensile bond strength of Dentaurum orthodontic stainless steel brackets by using 3M Unitek and Ormco as orthodontic adhesive agents. Materials and methods: Sixty-four extracted human upper first premolar teeth were selected and randomly divided into two groups with 32 teeth each, representing the shear and tensile bond strength testing groups. Then according to the type of bonding adhesive and the addition of Clinpro before
... Show More
Background: Pain is one of the most reported side effects of orthodontic treatment despite the advanced technology in orthodontics. Many analgesics have been introduced to control orthodontic pain including acetaminophen and selective and nonselective nonsteroidal anti-inflammatory drugs. The great concern about these drugs is their adverse effect on rate of teeth movement. Aims: The purpose of this study was to evaluate and compare the effect of acetaminophen, ibuprofen and etoricoxib on pain perception and their influence on the rate of teeth movement during leveling and alignment stage. Methods: Forty patients were evenly and randomly distributed in a blinded way to one of four groups: placebo (starch capsules), acetaminophen 500mg th
... Show MoreCO2 laser (10.6 μm) is the most often used laser in the oral surgery due to its high absorption by water of the oral tissues. Several benefits of the use of CO2 laser have been reported for oral surgical procedures. This study aims to evaluate the effect of CO2 laser on soft and hard oral tissues (in vitro study). This study was done on fresh tissues from sheep’s head. CO2Surgical Laser with different operation modes was used; 0.2 mm spot size using different laser parameters on the tongue, and bone making holes, incisions and cutting. The depths and widths of holes and incisions were measured using endodontic file under magnification. The speed of incisions was calculated and the required time for cutting was measured using sport clo
... Show MoreBackground: Dental erosion is a common oral condition which results due to consumption of high caloric and low pH acidic food such as carbonated drinks and fruit juices. It is expected that these food types can cause irreversible damage to dental hard tissues and early deterioration of the dental restorations. So, this study aimed to evaluate and compare the erosive potential effects of orange fruit juice and Miranda orange drink on the microhardness of an orthodontic composite material. Materials and methods: Thirty discs with a thickness of 2 mm and a diameter of 10 mm were prepared from orthodontic bonding composite. The prepared discs were equally divided into three groups (n=10). Microhardness analysis was carried out both prior to
... Show MoreComparison for the optical energy gap between pure
PMMA , PMMA-TiO2 micro composites and PMMA-TiO2 nano
composites have been investigated under uv – radiation , the
effect of time irradiation (0,6,12,24,48,72,96 and 120) have been
studied for these specimens to study the photic stability .The
results show that the photostability of the PMMA-TiO2
nanocomposite is higher than that of the pure PMMA and
PMMA-TiO2 micro composite under UV-light irradiation