Preferred Language
Articles
/
URd255IBVTCNdQwCOMM9
Modules Whose St-Closed Submodules are Fully Invariant
...Show More Authors

The duo module plays an important role in the module theory. Many researchers generalized this concept such as Ozcan AC, Hadi IMA and Ahmed MA. It is known that in a duo module, every submodule is fully invariant. This paper used the class of St-closed submodules to work out a module with the feature that all St-closed submodules are fully invariant. Such a module is called an Stc-duo module. This class of modules contains the duo module properly as well as the CL-duo module which was introduced by Ahmed MA. The behaviour of this new kind of module was considered and studied in detail,for instance, the hereditary property of the St-duo module was investigated, as the result; under certain conditions, every St-closed submodule of an St-duo module is also St-duo. Another characterization of the Stc-duo module was given. Additionally, the relationships of St-duo among some types of modules were investigated and discussed, for example; In the class of semi-extending modules, every weak duo module is anStc-duo module.Also, the authors gave a case in which St-duo, duo, CL-duo and weak duo are equivalent. Furthermore, the St-duo module was used to make the concepts semi-extending and FI-extending equivalent

Scopus Clarivate Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Sat Jan 05 2019
Journal Name
Iraqi Journal Of Physics
Study of optical bistability in a fully optimized laser Fabry-Perot system
...Show More Authors

The analytical study of optical bistability is concerned in a fully
optimized laser Fabry-Perot system. The related phenomena of
switching dynamics and optimization procedure are also included.
From the steady state of optical bistability equation can plot the
incident intensity versus the round trip phase shift (φ) for different
values of dark mistuning 




12
,
6
,
3
,
1.5
0 , o
   
 or finesse (F= 1, 5, 20,
100). In order to obtain different optical bistable loops. The inputoutput
characteristic for a nonlinear Fabry-Perot etalon of a different
values of finesse (F) and using different initial detuning (φ0) are used
in this rese

... Show More
View Publication Preview PDF
Crossref
Publication Date
Fri Jan 01 2016
Journal Name
Journal Of Engineering
Thermal Characteristics of Closed Wet Cooling Tower Using Different Heat Exchanger Tubes Arrangement
...Show More Authors

This paper presents thermal characteristics analysis of a modified Closed Wet Cooling Tower (CWCT) based on heat and mass transfer principles to improve the performance of this tower in Iraq. A prototype of CWCT optimized by added packing was designed, manufactured and tested for cooling capacity of 9 kW. Experiments are conducted to explore the effects of various operational and conformational parameters on the thermal performance. In the test section, spray water temperature and both dry bulb temperature and relative humidity of the air measured at intermediate points of the heat exchanger and packing. Heat exchangers consist of four rows and eight columns for an inline tubes arrangement and six rows and five columns f

... Show More
View Publication Preview PDF
Publication Date
Tue Aug 15 2023
Journal Name
Al-academy
Narrative infrastructure and its impact on building open and closed endings in the feature film
...Show More Authors

The topic of the research tagged (narrative structure and its impact on building open and closed endings in the fictional film) is summarized by studying the mechanism of employing closed and open endings in the fictional film. novelist, then the need for it, as well as the objectives of the research and clarifying its limits as well as its importance. Then moving to the theoretical framework, which included three topics, where the first topic was entitled (the cinematic construction of the film narrative), either the second topic (the structure of complexity and narrative solutions), or the third topic dealt with the subject (the structure of the end and its relationship to the construction of the narrative). After completing the theore

... Show More
View Publication Preview PDF
Crossref
Publication Date
Fri Dec 03 2021
Journal Name
Rawal Medical Journal
Functional outcome of interlocked intramedullary nailing fixation in management of closed tibia shaft fractures
...Show More Authors

Objective: To assess prospectively functional outcome of interlocked intramedullary nailing fixation in management of closed tibia shaft fractures. Methodology: This prospective study included 134 patients with closed shaft tibia fractures with age 18-60 years and isolated closed fracture of shaft of tibia. The fractures were fixed by interlocking intramedullary nail. At follow-up after 12 months postoperatively, the functional outcome was assessed radiographically for the sign of union and clinically according to Klemm-Borner criteria. Results: The mean age was 38.55 years. Out of 134 patients, 55.2% were male. The cause was road traffic accident in 44.8%, majority of the fracture occur in the mid-shaft (41.8%), and oblique fracture was th

... Show More
Preview PDF
Scopus (2)
Scopus
Publication Date
Thu Jun 30 2011
Journal Name
Al-kindy College Medical Journal
Are Indications For Esophago Gastro Duodenoscopy Properly Followed?
...Show More Authors

Background: Symptoms related to the upper gastro-intestinal tract are very common. Attribution of these symptoms to upper G. I. T.diseases are usually done on clinical bases, which could be confirmed by Esophago Gastro Duodenoscopy (EGD). The use of such tools might increase the diagnosis accuracy for such complaints. The indications for upper G I endoscopy might decrease the negative results of endoscopies.Objective: To follow strict indications for Esophago Gastro Duodenoscopy in order to decrease the negative endoscopy results. Methods: One thousand eight hundred and ninety cases were subjected to EGD from Feb. 1999 to Feb 2009 at Alkindy Teaching Hospital and Abd-Al-Majeed private hospital in Baghdad, Iraq. A special endoscopy unit f

... Show More
View Publication Preview PDF
Publication Date
Thu Dec 01 2011
Journal Name
Journal Of Engineering
THEORETICAL AND EXPERIMENTAL STUDY ON THERMAL PERFORMANCE OF CLOSED WET COOLING TOWER
...Show More Authors

Thermal performance of closed wet cooling tower has been investigated experimentally and theoretically
in this work. The theoretical model based on heat and mass transfer equations and heat and mass transfer balance equations which are established for steady state case. A new small indirect cooling tower was used for conducting experiments. The cooling capacity of cooling tower is 1 kW for an inlet water temperature of 38oC, a water mass velocity 2.3 kg/m2.s and an air wet bulb temperature of 26oC. This study investigates the relationship between saturation efficiency, cooling capacity and coefficient of performance of closed wet cooling tower versus different operating parameters such wet-bulb temperature, variable air-spray water fl

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun May 01 2022
Journal Name
Journal Of Engineering
Parametric Study of a Two-Phase Closed Thermosyphon Loop
...Show More Authors

A theoretical and experimental investigation was carried out to study the behavior of a two-phase closed thermosyphon loop (TPCTL) during steady-state operation using different working fluids. Three working fluids were investigated, i.e., distilled water, methanol, and ethanol. The TPCTL was constructed from an evaporator, condenser, and two pipelines (riser and downcomer). The driving force is the difference in pressure between the evaporator and condenser sections and the fluid returns to the heating section by gravity. In this study, the significant parameters used in the experiments were filling ratios (FR%) of 50%, 75%, and 100% and heat-input range at the evaporator section of 215-860.2 W. When the loop reached to

... Show More
View Publication Preview PDF
Crossref
Publication Date
Tue Mar 31 2015
Journal Name
Al-khwarizmi Engineering Journal
Temperature Effect on Photovoltaic Modules Power Drop
...Show More Authors

 Abstract

In order to determine what type of photovoltaic solar module could best be used in a thermoelectric photovoltaic power generation. Changing in powers due to higher temperatures (25oC, 35oC, and 45oC) have been done for three types of solar modules: monocrystalline , polycrystalline, and copper indium gallium (di) selenide (CIGS). The Prova 200 solar panel analyzer is used for the professional testing of three solar modules at different ambient temperatures; 25oC, 35oC, and 45oC and solar radiation range 100-1000 W/m2. Copper indium gallium (di) selenide module   has the lowest power drop (with the average percent

... Show More
View Publication Preview PDF
Publication Date
Mon Aug 01 2022
Journal Name
Journal Of Physics: Conference Series
Approximately Regular Rings and Approximately Regular Modules
...Show More Authors

Abstract In this work we introduce the concept of approximately regular ring as generalizations of regular ring, and the sense of a Z- approximately regular module as generalizations of Z- regular module. We give many result about this concept.

Scopus Crossref
Publication Date
Sat Apr 30 2022
Journal Name
Iraqi Journal Of Science
On Large-Lifting and Large-Supplemented Modules
...Show More Authors

      In this paper, we introduce the concepts of Large-lifting and Large-supplemented modules as a generalization of lifting and supplemented modules.  We also give some results and properties of this new kind of modules.

Scopus (1)
Scopus Crossref