Preferred Language
Articles
/
UBb7TYcBVTCNdQwCR0Pc
The Use of Osseodensification for Ridge Expansion and Dental Implant Placement in Narrow Alveolar Ridges: A Prospective Observational Clinical Study
...Show More Authors

The osseodensification (OD) drilling technique was suggested as an alveolar ridge expansion technique, so the aim of this prospective clinical study was to evaluate the amount of bone expansion obtained by the OD drilling technique and its effect on implant stability in patients with narrow alveolar ridges. The width of the alveolar ridge was measured at the crest before and after implant site preparation, whereas the implant stability was measured using Osstell Beacon implant stability quotient (ISQ). The ISQ values were recorded immediately postoperatively and after 16 weeks. Twenty-three patients were included; they received 40 implants. The mean (± standard deviation [SD]) amount of expansion was 1.29 (± 0.41) mm, and the difference between preexpansion and post-expansion bone width was statistically significant ( P < 0.001). The mean (± SD) primary stability was 73.73 (± 2.85) ISQ, whereas the mean (± SD) secondary stability was 74.83 (± 2.73) ISQ, and the difference was statistically significant ( P = 0.043). The implant survival rate was 100%. It can be concluded that using the OD technique in narrow alveolar ridges resulted in bone expansion without dehiscence or fenestration and allowed simultaneous implant placement with high primary and secondary implant stability.

Scopus Clarivate Crossref
View Publication
Publication Date
Mon Sep 30 2024
Journal Name
The Scientific World Journal
Relationship Between the Level of Vitamin D3 Deficiency and Successful Osseointegration: A Prospective Clinical Study
...Show More Authors

Purpose: This study aimed to evaluate the influence of vitamin D3 levels on bone density, primary dental implant stability, and successful osseointegration.

Materials and Methods: Clinical and radiological examination with a standardized cone‐beam computed tomography (CBCT) machine and laboratory investigation for serum levels of vitamin D3 were performed for all patients. Only patients in need of single or multiple straightforward dental implant surgery in either jaw with no history of systemic disease or condition that may interfere with bone healing were included in this study to receive the dental implant by the same oral and maxillofacial surgeon, which re‐opened

... Show More
View Publication Preview PDF
Scopus (7)
Crossref (11)
Scopus Crossref
Publication Date
Mon Sep 30 2024
Journal Name
The Scientific World Journal
Relationship Between the Level of Vitamin D3 Deficiency and Successful Osseointegration: A Prospective Clinical Study
...Show More Authors

Purpose: This study aimed to evaluate the influence of vitamin D3 levels on bone density, primary dental implant stability, and successful osseointegration.

Materials and Methods: Clinical and radiological examination with a standardized cone‐beam computed tomography (CBCT) machine and laboratory investigation for serum levels of vitamin D3 were performed for all patients. Only patients in need of single or multiple straightforward dental implant surgery in either jaw with no history of systemic disease or condition that may interfere with bone healing were included in this study to receive the dental implant by the same oral and maxillofacial surgeon, which re‐opened

... Show More
View Publication Preview PDF
Scopus (7)
Crossref (11)
Scopus Crossref
Publication Date
Mon Jan 01 2024
Journal Name
Journal Of Oral Medicine And Oral Surgery
Evaluating dental implant stability using three devices Osstell<sup>®</sup>, Periotest<sup>®</sup>, and AnyCheck<sup>®</sup>: a clinical study
...Show More Authors

Introduction: Implant stability is usually measured with resonance frequency analysis (RFA) and damping capacity assessment (DCA). This study aimed to measure primary and secondary stabilities using 3 devices that are based on these methods, namely; RFA (Osstell®) and DCA (Periotest® and AnyCheck®) to assess the correlations of the measurements obtained by these devices and the correlations between implant stability and insertion torque. Material and Methods: This observational prospective study included 35 dental implants. The implant stability was measured using the 3 devices. Mann–Whitney U

... Show More
View Publication
Scopus (6)
Crossref (7)
Scopus Crossref
Publication Date
Mon Jun 15 2020
Journal Name
Journal Of Baghdad College Of Dentistry
Evaluation of dental enamel color after fixed orthodontic therapy using two types of protectors to prevent white spot lesions (A prospective clinical study)
...Show More Authors

Background: The aim of this study is to evaluate the color change ∆E of the dental enamel following treatment with 2 kinds of protector (icon infiltrant, clinpro varnish) before fixed orthodontic treatment to avoid the possible white spot lesions. Materials and Methods: Fifty four subjects treated with fixed appliances were divided into 3 groups: the 1st group was control, while the 2nd and 3rd groups were treated with icon infiltrant and clinpro varnish before bonding procedure, respectively. Color parameters (L,a,b) were recorded for the middle and gingival thirds before and after bonding procedure to get the ∆E of each group. Results: One-way ANOVA test showed a non-significant difference in ∆E between the 3 groups a

... Show More
View Publication Preview PDF
Scopus Crossref
Publication Date
Fri Mar 28 2025
Journal Name
Cumhuriyet Dental Journal
Evaluation of Patient Satisfaction with Orthodontic Care Provision (A Prospective Clinical Study)
...Show More Authors

Objective: Patient satisfaction is critical to ensure patient adherence during orthodontic treatment. This study aimed to evaluate patient satisfaction with orthodontic care and related services provided for Iraqi sample at the College of Dentistry, University of Baghdad. Materials and Methods: A questionnaire-based prospective study was conducted to assess patient satisfaction by using a three-point response rating. The questionnaire contained seven sections divided into 21 questions that covered overall patient relationship with the orthodontic staff, proposed treatment explanation, and orthodontic treatment quality. The questionnaire standard was set so that at least 90% “always” response should be shown by all

... Show More
View Publication Preview PDF
Scopus (2)
Crossref (2)
Scopus Crossref
Publication Date
Sun Oct 04 2026
Journal Name
Journal Of Baghdad College Of Dentistry
The initial stability of dental implant with horizontal plate (An in vitro study)
...Show More Authors

Background: The Initial (primary) stability is one of the factors that play an important role in the success of the dental implants. The purpose of this study was to evaluate the initial stability of dental implant with horizontal plate by using five analytical tests: insertion torque, removal torque, resonance frequency analysis, push-in test and pull-out test. Materials and methods: Two different lengths of dental implants (5mm and 10mm) were tested in this study; each dental implant was 4mm in diameter with a square threads shape of 1mm pitch and 0.5mm depth. The crestal area was 4.2mm diameter contained a right angle margin circumferential ring while the apical area was tapered with two self-tapping grooves. In this study, the initial s

... Show More
View Publication Preview PDF
Publication Date
Sun Oct 04 2026
Journal Name
Journal Of Baghdad College Of Dentistry
Occupational dental wear among El-Kubasis cement factory workers - An observational study
...Show More Authors

Background: Loss of tooth structure may be due to tooth to tooth contact and presence of abrasive components in the work environment. The aim of study was planned to evaluate the occurrence of dental attrition among Cement factory workers. Material and Method: The Sample included all workers chronically exposed to cement dust in the EL-Kubaisa cement factory (95 workers). A comparative group of workers (97) were non-exposed to cement dust was selected. All workers were males in gender with age range (25-55) years. The assessment of tooth wear was based on the criteria of smith and knight, 1984. Results: The maximum tooth wear score for exposed workers was 84.2% while non exposed workers was 38.1%,with statistical differences between two g

... Show More
View Publication Preview PDF
Publication Date
Wed Apr 01 2026
Journal Name
Journal Of Dentistry
Comparison of the accuracy of Robotic arm and Dynamic Navigation in the placement of mandibular dental implants: An in-vitro study
...Show More Authors

View Publication Preview PDF
Scopus Crossref
Publication Date
Mon Aug 31 2020
Journal Name
Bmc Oral Health
The success of using 2% lidocaine in pain removal during extraction of mandibular premolars: a prospective clinical study
...Show More Authors
Abstract<sec><title>Background

The purpose of this study was to evaluate the anesthetic effectiveness of a buccal infiltration technique combined with local massage (using 2% lidocaine) in the extraction of mandibular premolars to be utilized as an alternative to the conventional inferior alveolar nerve block.

Methods

Patients eligible included any subject with a clinical indication for tooth extraction of the mandibular 1st or 2nd premolars. All patients were anesthetized buccally by local infiltration technique followed by an external pressure applied for 1 min directly over the injection area. In each case, another local

... Show More
View Publication
Scopus (5)
Crossref (9)
Scopus Crossref
Publication Date
Mon Jan 01 2024
Journal Name
Journal Of Stomatology
The effect of Winter’s red line, angle of impaction, and radio-morphometric indices on surgical difficulty of impacted mandibular third molar: a prospective observational study
...Show More Authors

View Publication
Scopus (1)
Crossref (1)
Scopus Crossref