Efficient management of treated sewage effluents protects the environment and reuse of municipal, industrial, agricultural and recreational as compensation for water shortages as a second source of water. This study was conducted to investigate the overall performance and evaluate the effluent quality from Al- Rustamiya sewage treatment plant (STP), Baghdad, Iraq by determining the effluent quality index (EQI). This assessment included daily records of major influent and effluent sewage parameters that were obtained from the municipal sewage plant laboratory recorded from January 2011 to December 2018. The result showed that the treated sewage effluent quality from STP was within the Iraqi quality standards (IQS) for disposal and the overall efficiency indicated a positive efficiency of the STP within the order BOD > COD > TSS > chloride. The results revealed that the effluent quality index (EQI) lied under a good water category for both effluent disposal and irrigation use. The multiple linear regression model (MLR) was used for the prediction of EQI and the results provided good estimates for the EQI data sets with a high coefficient of determination (R2=98%). From this analysis, EQI is highly significantly interrelated with TSS, BOD5, and COD within the values 88.9%, 78.6%, and 76.3% respectively. The artificial neural network (ANN) model was developed to predict the effluent quality index based on the selected sewage characteristics. Results provided good estimates for the EQI data sets with a high coefficient of determination (R2=99.8%) and lower relative error and TSS was more effective on the EQI model other than parameters with the relative importance 47.3%. So, the MLR and ANN models were found to provide an effective tool in efficient predicting EQI that can be used effectively to monitor effluent parameters and describe the suitability of treated sewage to quality achieved according to Iraqi quality standards (IQS) for effluent disposal and Food Agriculture Organization (FAO) standards for irrigation purposes.
The increase in population resulted in an increase in the consumption of water. The present work investigates the performance of a recycling solar- powered greywater treatment system for the purposes of irrigation, used to reduce the amount of waste grey water and reduce electricity consumption and reduce the costs of constructing large scale water treatment plants. The system consumes about 3814W per hour and provides water treatment about 1.4 m3 per day. The proposed system is designed to residential, office and governmental buildings application. Tests are conducted in an office building at the Ministry of Science and Technology site in Baghdad. Laboratorial water samples testing analyses are co
... Show MoreBackground and objectives: Whether to use a cold scalpel or laser surgery to remove a lesion in the skin of the craniofacial area is the main question the surgeon asks him- or herself to do. The study tried to extend the literature with data that may help the surgeons to choose the right method. Methods: Thirty patients with intra- and extraoral craniofacial skin lesions managed by Carbone dioxide (CO2) laser surgery. Results: The most common type of lesion treated was melanocytic nevi (15 patients; 50%). Conclusion: The main complication of CO2 laser surgery is the remaining permanent hypopigmentation of the treated area; however, the CO2 laser has many advantages (especially at the time of surgery) making it a good choice for the manageme
... Show MoreThis research evaluated the effect of (UV)(400-320A)Hz(320-220B)Hz on the patient with vitiligo , using it with our new combing therapy that include the oral (Psorlene ) topical , meladinine solution applied on the Vitiligiousns Lesions , In edition to the instralesnional injection in the Vitiligiousns Lesions by long acting steroid (kenacort-A ) by aprecentage of (5%) , after that we expose the patient to UV . The ruslets of this way of treatment more effective by using of the UV rays in the treatment of vitiligo , while the previous treatment that used the UV ray with or with out the psorlene , the results were not effective on controlling of the Vitiligio diseases comparing by the treatment used in this research as it stop’s the sp
... Show MoreIron slag is a byproduct generated in huge quantities from recycled remnants of iron and steel factories; therefore, the possibility of using this waste in the removal of benzaldehyde from contaminated water offers an excellent topic in sustainability field. Results reveal that the removal efficiency was equal to 85% for the interaction of slag and water contaminated with benzaldehyde at the best operational conditions of 0.3 g/100 mL, 6, 180 min, and 250 rpm for the sorbent dosage, initial pH, agitation time, and speed, respectively with 300 mg/L initial concentration. The maximum uptake capacity of iron slag was 118.25 mg/g which was calculated by the Langmuir model. Physical sorption may be the major mechanism for the removal of
... Show MoreThe determination of river pollution impact on the performance of water treatment plants is achieved by two main objectives. The first is to study raw and treated water qualities and comparing them with standards and the second is to evaluate the treatment plants efficiency. The analyzed data were those water quality parameters in relation to physical, chemical and bacteriological characteristics for river water and produced water by seven water treatment plants located on Tigris River passing through Baghdad City.
The results of this study indicated that all raw water characteristic are within the surface water standards established by Iraqi and USA criteria except Bacterial Counts.
Tigris River water is of good quality to be trea
Background: Recurrent aphthous ulceration (RAU) is an inflammatory condition of unknown etiology characterized by painful recurrent (single or multiple) ulcerations of the oral mucosa. It is one of the most common and poorly understood mucosal disorders. It occurs more frequently in times of stress. Local and systemic conditions, genetic, immunologic, microbial factors, and oxidative stress may play a role in the pathogenesis of RAU. The objective of this study was to evaluate the free radical metabolism and antioxidant activity of RAU patients treated by lavender or flax oil paint.
Materials and Methods: Sixty-six RAU patients were enroll
... Show MoreCombining ultrasonic irradiation and the Fenton process as a sono-Fenton process, the chemical oxygen demand (COD) in refinery wastewater was successfully eliminated using response surface methodology (RSM) with central composite design (CCD). The impact of two main influential operational parameters (iron dosage and reaction time) on the COD removal from wastewater generated by an Iraqi petroleum refinery facility was explored. Removal of 85.81% was attained under the optimal conditions of 21 minutes and 0.289 mM of concentration. Additionally, the results revealed that the concentration of has the highest effect on the COD elimination, followed by reaction time. The high R2 value (96.40%) validated the strong fit of the mo
... Show MoreResearch Summary :
Praise be to God, Lord of the Worlds, and prayers and peace be upon the Master of the Messengers, his family and all his companions, then after:
This is a brief research that contained its two rudders the command and its Style in Surat Al-Ma’idah a fundamental rhetorical study, and the study clarified the meaning of imperative in both; the Arabic language and in the terminology of the fundamentalists and rhetoricians in a concise manner, and then indicated the imperative of the command , the true meaning, and the meanings interpretated as an imperative form. I have mentioned some verses of Surat Al-Ma’idah, so what I have quot
... Show MoreIn the present study, the effectiveness of a procedure of electrocoagulation for removing chemical oxygen demand (COD) from the wastewater of petroleum refinery has been evaluated. Aluminum and stainless steel electrodes were used as a sacrificial anode and cathode respectively. The effect of current density (4-20mAcm−2), pH (3-11), and NaCl concentration (0-4g/l) on efficiency of removal of chemical oxygen demand was investigated. The results have shown that increasing of current density led to increase the efficiency of COD removal while increasing NaCl concentration resulted in decreasing of COD removal efficiency. Effect of pH was found to be lowering COD re