In these recent years, the world has witnessed a kind of social exclusion and the inability to communicate directly due to the Corona Virus Covid 19 (COVID-19) pandemic, and the consequent difficulty of communicating with patients with hospitals led to the need to use modern technology to solve and facilitate the problem of people communicating with each other. healthcare has made many remarkable developments through the Internet of things (IOT) and cloud computing to monitor real-time patients' data, which has enabled many patients' lives to be saved. this paper presents the design and implementation of a Private Backend Server Software based on an IoT health monitoring system concerned emergency medical services utilizing biosensors to detect multivital signs of an individual with an ESP32 microcontroller board and IoT cloud. The device displays the vital data, which is then uploaded to a cloud server for storage and analysis over an IoT network. Vital data is received from the cloud server and shown on the IoT medical client dashboard for remote monitoring. The proposed system allows users to ameliorate healthcare jeopardy and minify its costs by recording, gathering, sharing, and analyzing vast biodata streams such as Intensive Care Units (ICU) (i.e., temperature, heartbeat rate, Oxygen level (CO2), etc.), efficiently in real-time. In this proposal, the data will send from sensors fixed in the patient body to the Web and Mobile App continually in real time for collection and analysis.
The evolution of the Internet of things (IoT) led to connect billions of heterogeneous physical devices together to improve the quality of human life by collecting data from their environment. However, there is a need to store huge data in big storage and high computational capabilities. Cloud computing can be used to store big data. The data of IoT devices is transferred using two types of protocols: Message Queuing Telemetry Transport (MQTT) and Hypertext Transfer Protocol (HTTP). This paper aims to make a high performance and more reliable system through efficient use of resources. Thus, load balancing in cloud computing is used to dynamically distribute the workload across nodes to avoid overloading any individual r
... Show More
CD-nanosponges were prepared by crosslinking B-CD with diphenylcarbonate (DPC) using ultrasound assisted technique. 5-FU was incorporated with NS by freeze drying, and the phase solubility study, complexation efficiency (CE) entrapment efficiency were performed. Also, the particle morphology was studied using SEM and AFM. The in-vitro release of 5-FU from the prepared nanosponges was carried out in 0.1N HCl.
5-FU nanosponges particle size was in the nano size. The optimum formula showed a particle size of (405.46±30) nm, with a polydispersity index (PDI) (0.328±0.002) and a negative zeta potential (-18.75±1.8). Also the drug entrapment efficiency varied with the CD: DPC molar ratio from 15.6 % to 30%. The SEM an
... Show MoreIn this research, an enhancement in lubricating, rheological, and filtration properties of unweighted water-based mud is fundamentally investigated using XC polymer NPs with 0.2gm, 0.5gm, 1gm, 2gm, and 4gm concentrations. Bentonite, that had been used in the preparation of unweighted water-based mud, was characterized using XRF-1800 Sequential X-ray Fluorescence Spectrometer, XRD-6100/7000 X-ray Diffractometer, and Malvern Mastersizer 2000 particle size analyzer, respectively. Lubricating, rheology and filtration properties of unweighted water-based mud were measured at room temperature (35°C) using OFITE EP and Lubricity Tester, OFITE Model 900 Viscometer, and OFITE Low-Pressure Filter Press, respectively. XC Polymer N
... Show MoreSummary:The anatomy of the arterial and venous vessels of the mammalian oviduct is well describedin women and in laboratory and farm animals. The arteries are derived from the ovarian anduterine stems; the relative contribution of these vessels, however, or variations in that contributionwith the menstrual or estrus cycle and/or gamete or embryo transport is unknown.
The MTS-88. c trainer is a training system targeting students in the microprocessors course. It has a built in single-line assembler allowing the users to enter programs in assembly. It has the problem that long programs cannot be traced and tested efficiently. A simple error may cause all the code to be erased and the system to stop responding. Also, this system lacks the ability to be connected to the PC. The aim of this work is to modify the system to make it possible to be connected to the PC through the parallel port. This gives the capability to download long programs to the system after being developed in the PC. The 8255 Programmable Peripheral Interface available in the teaching system is interfaced to the parallel port and used as
... Show MoreFluid-structure interaction method is performed to predict the dynamic characteristics of axial fan system. A fluid-structure interface physical environment method (monolithic method) is used to couple the fluid flow solver with the structural solver. The integration of the three-dimensional Navier-Stokes equations is performed in the time Doman, simultaneously to the integration of the three dimensional structural model. The aerodynamic loads are transfer from the flow to structure and the coupling step is repeated within each time step, until the flow solution and the structural solution have converged to yield a coupled solution of the aeroelastic set of equations. Finite element method is applied to solve numerically
... Show MoreObjectives: Evaluation of school health surveillance system with Indicate the level of usefulness of this system,
in addition to Describe the system.
Methodology: A probability multistage sample of (54) subjects which is selected the school health units from
the health institutions. Questionnaire has been divided into three main parts consist, form(A) especially for
health directorate, form (B) for health sectors, and form (C) for primary health care centers; each form contains
the basic components, structure, process, outcome, total items of questionnaire was ( 74) items.
Results: The study results indicate that the system is average adequacy, simple, moderately flexible, highly
acceptance, representative, low utili