Preferred Language
Articles
/
TxdlspIBVTCNdQwCM74r
The utility of a novel vacuum-assisted foreign body extraction technique from wounds
...Show More Authors

Retained soft tissue foreign bodies following injuries are frequently seen in the Emergency and Plastic Surgery practice. The patients with such presentations require a watchful and detailed clinical as- sessment to overcome the anticipant possibility of missing them. However, the diagnosis based on the clinical evaluation is usually challenging and needs to be supported by imaging modalities that are suboptimal and may fail in identifying some types of foreign bodies. Owing to that, serious complications such as chronic pain, infection, and delayed wound healing can be faced that necessitate a prompt intervention to halt those detrimental consequences. The classical method of removal is a surgical exploration which is not free of risks. It can cause injuries to vital structures such as nerves and tendons if the foreign body is close to them, also it can be affected by the surgeon’s experience and the foreign body’s char- acteristics. In light of that, we conducted a single-center study to understand the utility of a novel vacuum-assisted technique for foreign body removal. The technique is noninvasive and facilitates a real-time foreign body extraction using readily available materials. Twenty patients with 23 Foreign Bodies of various kinds, shapes, and sizes were recruited in our study by using a nonprobability convenient sampling method. Results demonstrated the ability of the described technique to extract 22 of them with no noticeable side effects. This study may encourage further trials adopting similar principles to promote the management of retained foreign bodies with fewer complications, and a potential of time and cost-saving.

Publication Date
Mon Dec 21 2020
Journal Name
Bulletin Of The Iraq Natural History Museum (p-issn: 1017-8678 , E-issn: 2311-9799)
A CONTRIBUTION TO THE CHECKLIST OF THE JUMPING SPIDERS (ARANEAE: SALTICIDAE) OF ARMENIA
...Show More Authors

The paper presents an annotated checklist of the Salticidae of Armenia. This study was carried out in 2019-2020 in order to provide an inventory of the Salticidae fauna. Thirteen species are reported for the Armenian fauna for the first time: Afraflacilla epiblemoides (Chyzer, 1891); Aelurillus v-insignitus (Clerck, 1757); Asianellus festivus (C. L. Koch, 1834); Heliophanus dubius C. L. Koch, 1835; Heliophanus kochii Simon, 1868; Heliophanus tribulosus Simon, 1868; Heliophanus curvidens (O. Pickard-Cambridge, 1872); Macaroeris nidicolens (Walckenaer, 1802); Pellenes diagonalis (Simon, 1868); Pellenes geniculatus (Simon, 1868); Pellenes seriatus (Thorell, 1875); Pellenes tripunctatus (Walckenaer, 1802) and Phlegra fasciata (Hahn, 1826).

... Show More
View Publication Preview PDF
Scopus (5)
Crossref (2)
Scopus Crossref
Publication Date
Wed May 17 2023
Journal Name
Journal Of Engineering
A Simulation of Core Displacement Experiments for the Determination of the Relative Permeability
...Show More Authors

Computations of the relative permeability curves were made through their representation by two functions for wetting and nonwetting phases. Each function contains one parameter that controls the shape of the relative permeability curves. The values of these parameters are chosen to minimize an objective function, that is represented as a weighted sum of the squared differences between experimentally measured data and the corresponding data calculated by a mathematical model simulating the experiment. These data comprise the pressure drop across core samples and the recovery response of the displacing phase. Two mathematical models are constructed in this study to simulate incompressible, one-dimensional, two-phase flow. The first model d

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Sat May 02 2020
Journal Name
Karbala Journal Of Physical Education Sciences
The effect of using a designed device to develop the technical performance of the descending landing skill facing with half a cycle on the parallel device of the technical men's
...Show More Authors

AS Salman, SK Hameed…, Karbala Journal of Physical Education Sciences, 2020

View Publication
Publication Date
Wed Jan 01 2014
Journal Name
كلية التربية -الجامعة المستنصرية
study the electron drift velocity in gas mixtures of SF6 with N2 obtained from Boltzmann equation analysis
...Show More Authors

Publication Date
Tue Dec 01 2015
Journal Name
Journal Of Engineering
Calibration and Verification of the Hydraulic Model for Blue Nile River from Roseires Dam to Khartoum City
...Show More Authors

This research represents a practical attempt applied to calibrate and verify a hydraulic model for the Blue Nile River. The calibration procedures are performed using the observed data for a previous period and comparing them with the calibration results while verification requirements are achieved with the application of the observed data for another future period and comparing them with the verification results. The study objective covered a relationship of the river terrain with the distance between the assumed points of the dam failures along the river length. The computed model values and the observed data should conform to the theoretical analysis and the overall verification performance of the model by comparing i

... Show More
View Publication Preview PDF
Publication Date
Mon Mar 15 2021
Journal Name
Journal Of Baghdad College Of Dentistry
Comparison between the mesiodistal crown dimensions of second primary molar with stainless steel crowns from different companies
...Show More Authors

Background: Due to the variations in tooth anatomy and size among different populations, this study aimed to compare the mesiodistal width of primary second molars in Iraqi children with the mesiodistal width of stainless-steel crowns from different companies. Materials and Methods: This cross-sectional study was conducted on 220 intact maxillary and mandibular primary second molars selected from boys and girls’ Iraqi children aged 8-9 years collected from different primary schools in Baghdad city. The mesiodistal dimensions of the selected teeth and the available maxillary and mandibular stainless-steel crowns from three different companies were measured by using a 3-D scanner, and then the whole measurements were calculated usin

... Show More
View Publication Preview PDF
Scopus (1)
Crossref (2)
Scopus Crossref
Publication Date
Sun Sep 06 2015
Journal Name
Baghdad Science Journal
The Bactericidal Effect of CO2 Laser on Pseudomonas aeruginosa Isolated from Wound and Burn Infections, In-Vitro
...Show More Authors

A total of 60 cotton swabs are collected from patients suffering from burn wound and surgical site infections admitted to Baghdad Teaching Hospital and Burn Specialist Hospital in Baghdad city during 9/2013 to 11/2013. All cotton swabs are cultured initially on blood agar and MacConkey agar and subjected for standard bacteriological procedures for bacteriological diagnosis. Twenty samples out of sixty are identified as Pseudomonas aeruginosa by conventional methods. The results of antibiotic susceptibility test illustrate that the antibiotics resistance rate of Pseudomonas aeruginosa isolates is as follows:100% (2020) for ceftriaxone, cefepime and carbencillin, 70% (14/20) for amikacin, 65%(13/20) for tobramycin, ceftazidim and gentamycin,

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Sat Apr 01 2017
Journal Name
Journal Of Engineering
Comparative Study between Nanofiltration and Reverse Osmosis Membranes for the Removal of Heavy Metals from Electroplating Wastewater
...Show More Authors

The present work aimed to study the efficiency of nanofiltration (NF) and reverse osmosis (RO) process for water recovery from electroplating wastewater and study the factors affecting the performance of two membrane processes. Nanofiltration and reverse osmosis membranes are made from polyamide as spiral wound module. The inorganic materials ZnCl2, CuCl2.2H2O, NiCl2.6H2O and CrCl3.6H2O were used as feed solutions. The operating parameters studied were: operating time, feed concentrations for heavy metal ions, operating pressure, feed flow rate, feed temperature and feed pH. The experimental results showed, the permeate concentration increased and water flux decreased with increase in time from 0 to 70 min. The permeate concentrations incre

... Show More
Preview PDF
Publication Date
Tue Dec 01 2015
Journal Name
Journal Of Engineering
Calibration and verification of the hydraulic model for Blue Nile river from Roseires dam to Khartoum city
...Show More Authors

This research represents a practical attempt applied to calibrate and verify a hydraulic model for the Blue Nile River. The calibration procedures are performed using the observed data for a previous period and comparing them with the calibration results while verification requirements are achieved with the application of the observed data for another future period and comparing them with the verification results. The study objective covered a relationship of the river terrain with the distance between the assumed points of the dam failures along the river length. The computed model values and the observed data should conform to the theoretical analysis and the overall verification performance of the model by comparing it with anothe

... Show More
Publication Date
Fri Mar 31 2017
Journal Name
Journal Of Engineering
Comparative Study between Nanofiltration and Reverse Osmosis Membranes for the Removal of Heavy Metals from Electroplating Wastewater
...Show More Authors

The present work aimed to study the efficiency of nanofiltration (NF) and reverseosmosis (RO) process for water recovery from electroplating wastewater and study the factors affecting the performance of two membrane processes. Nanofiltration and reverse osmosismembranes are made from polyamide as spiral wound module. The inorganic materials ZnCl 2 CuCl2 .2H2O, NiCl.2.6H2O and CrCl3.6H2O were used as feed solutions. The operating parametersstudied were: operating time, feed concentrations for heavy metal ions, operating pressure, feed flow rate, feed temperature and feed pH. The experimental results showed, the permeateconcentration increased and water flux decreased with increase in time from 0 to 70 min. Thepermeate concentrations incre

... Show More
View Publication Preview PDF