Introduction: Infection control or hospital-acquired infections are the major concern of the health care system and agencies. Critical care nurses are on the first-line contact with the patients, so on, they are most vulnerable to acquired infections. It is really important to regularly check their knowledge and practices concerning infection control. Objectives: The study aims to identify the impact of years’ experience on nurses’ knowledge and practices concerning infection control in three hospitals and center (Baghdad teaching hospital, Ibn Al-Nafees hospital, and Ibn al-Bitar center) Methodology: Cross-sectional study was conducted, the study starting from 4th of July 2020 to 13th of November 2020. Non-probability (purposive) sample was used to select 110 nurses who work at critical care units in three hospitals and center (Baghdad teaching hospital, Ibn Al-Nafees hospital, and Ibn al-Bitar center). The years of experience should no less than one year. The instrument was composed of two parts. Firstly, covers the nurses’ demographic characteristics. Secondly, included self-report questions about nurses’ knowledge and an evaluation sheet concerning nurses’ practices of infection control with 24 questions for knowledge and 12 questions for practices checklist. Results: The study revealed that the nurses’ knowledge toward infection control record 38%, 41%, and 21% for low, moderate, and high knowledge respectively. In comparison, nurses practices record 47%, 42%, and 11% for low, moderate, and high practices respectively. Most of the study sample 62% was females while 38 % of the subject was males. The age group (20-29) takes the highest percentage (38%), In addition, about (27.3%) of the nurses who works in critical care units have 1-5 years of experience. Significant statistical associations were found between nurses knowledge and practice from one hand and years’ experience on the other hands p ? 0.05. Recommendation: Based on this finding, the researcher recommended further studies involve more nurses and other health professionals regarding infection control and highlight the importance of infection control to nurses with (1-5) years’ experience by symposium or teaching programs.
Urinary Schistosomiasis is one of important diseases that cause irritation and damage of urinary tract and other systems and tissues and can not be expected by doctors when diagnosing urinary tract diseases.The current study is conducted to investigate the prevalence of schistosomiasisin Baghdad / Al-Rusafa. 191urine samples were collected fromresidents ofsome areas of Al-Rusafain Baghdad governarate (Almashtal, Albaladyat, Alameen, Baghdad aljadida and Alnahrawan) for the period from March until the end of September 2010.The samples were examined by the precipitation and examination of micro hematuria by reagent strips. The total infection percentage was 9.42% (18/191) and was significantly higher in males compared tofemales12.64% (11/87)
... Show MoreGround water hydrochemical study in Yusufiyah depends upon (25) wells where major cations and anions were obtained as well as trace elements. The hydrochemical properties include the study of (pH, EC, TDS, and TH). The groundwater of the study area is odorless and colorless except the wells (13 and 16) with a salty taste due to the elevated (TDS) concentration in it, where the wells depth ranges between 7-20 meters. Depth of water in these wells was about 25-35 meters above sea level. Groundwater generally flows from east to west and from north east to south west. The resource of groundwater depends upon surface water. Physical specifications are measured in the water samples included temperature, color, taste, odor, pH, electrical condu
... Show More
An attempt was made to evaluate the PV performance of one-axis daily tracking and fixed system for Baghdad, Iraq. Two experimental simulations were conducted on a PV module for that purpose. Measurements included incident solar radiation, load voltage and load current. The first experiment was carried out for six months of winter half of year to simulate the one-axis daily tracking. The azimuth angle was due south while the tilt angle was being set to optimum according to each day of simulation. The second experiment was done at one day to simulate the PV module of fixed angles. It is found that there is a significant power gain of 29.6% for the tracking system in respect to the fixed one. The one-axis daily tracking was much more effect
... Show MoreThe influence of 5-10 kHz audio frequency on the power dissipation in ac discharge of argon gas was studied experimentally, at pressures 50-80 mTorr and electrodes separation 10 cm (pd range 0.5-0.8 Torr.
cm). The measurements have shown that the discharge behavior in the ac circuit is equivalent to a series RC circuit. It is observed that the variation curve of discharge power P with the frequency f is approximately has a Gaussian shape. It is also observed that the curve of Pm- pd is the inverse of Paschen curve, where Pm is the maximum power in the frequency range. The time of breakdown is estimated from the curve of P- f.
In this paper, the Active Suspension System (ASS) of road vehicles was investigated. In addition to the conventional stiffness and damper, the proposed ASS includes a fuzzy controller, a hydraulic actuator, and an LVDT position sensor. Furthermore, this paper presents a nonlinear model describing the operation of the hydraulic actuator as a part of the suspension system. Additionally, the detailed steps of the fuzzy controller design for such a system are introduced. A MATLAB/Simulink model was constructed to study the proposed ASS at different profiles of road irregularities. The results have shown that the proposed ASS has superior performance compared to the conventional Passive Suspension System (PSS), where the body displacemen
... Show MoreQuality control is an effective statistical tool in the field of controlling the productivity to monitor and confirm the manufactured products to the standard qualities and the certified criteria for some products and services and its main purpose is to cope with the production and industrial development in the business and competitive market. Quality control charts are used to monitor the qualitative properties of the production procedures in addition to detecting the abnormal deviations in the production procedure. The multivariate Kernel Density Estimator control charts method was used which is one of the nonparametric methods that doesn’t require any assumptions regarding the distribution o
... Show More