Preferred Language
Articles
/
TRdbspIBVTCNdQwCnr54
7 SMAS Plasty in Face Lift with Fat Graft: Evaluation of Aesthetic Outcomes
...Show More Authors

ABSTRACT: BACKGROUND: The main goal of facelift surgery is to reduce the effect of aging by reposition of face soft tissue in to more youthful orientation. There are many methods for SMAS plication which had different design and vector of pull. AIM OF STUDY: To evaluate the effectiveness and longitivity of 7 shaped SMAS plication in facelift. PATIENT AND METHODS: From January 2020 to march 2021, 10 female patients with age (45-60) years were presented with facial sagging, those patients were subjected to subcutaneous facelift with 7 shaped SMAS plication with fat greft in Al-Shaheed Ghazi Al-Harri Hospital and Baghdad burn medical center at Baghdad medical complex. RESULTS: The average follow up period was 6 to 12 months. The mean operative time was 1 hour and 30 minutes. Additional facial procedures were later done which including: fat injection (all patients), brow lift (one patient), facial scar subcision with fat grafting (one patient) and sub mental liposuction with platysma plication (2 patient). All of our patients demonstrate high level of subjective satisfaction with quick recovery with no major or minor complications CONCLUSION: The subcutaneous facelift with 7 shaped SMAS plication is simple to learn with high patients satisfaction and long lasting result.

Publication Date
Fri Jul 17 2026
Journal Name
Journal Of Baghdad College Of Dentistry
Evaluation of a new orthodontic bonding system (Beauty Ortho Bond)
...Show More Authors

Background: The purpose of the current study was to evaluate the efficacy of a new orthodontic bonding system (Beauty Ortho Bond) involving the shear bond strength in dry and wet environments, and adhesion remnant index (ARI) scores evaluation in regard to other bonding systems (Heliosit and Resilience Orthodontic Adhesives). Materials and methods: Sixty defect free extracted premolars were randomly divided into six groups of 10 teeth each, mounted in acrylic resin, three groups for a dry environment and three for a wet one. Shear bond strength test was performed with a cross head speed of 0.5 mm/min, while surfaces of enamel and bracket-adhesive-enamel surfaces were examined with stereomicroscope For ARI scores evaluation. Data were analyz

... Show More
View Publication Preview PDF
Publication Date
Sat Aug 18 2018
Journal Name
Journal Of Engineering And Applied Sciences
Performance Evaluation of Transport Protocols for Mobile Ad Hoc Networks
...Show More Authors

Mobile Ad hoc Networks (MANETs) is a wireless technology that plays an important role in several modern applications which include military, civil, health and real-time applications. Providing Quality of Service (QoS) for this application with network characterized by node mobility, infrastructure-less, limitation resource is a critical issue and takes greater attention. However, transport protocols effected influential on the performance of MANET application. This study provides an analysis and evaluation of the performance for TFRC, UDP and TCP transport protocols in MANET environment. In order to achieve high accuracy results, the three transport protocols are implemented and simulated with four different network topology which are 5, 10

... Show More
View Publication
Publication Date
Mon Dec 10 2007
Journal Name
Iraqi Journal Of Laser
Evaluation of breast mass excision by 810 nm diode laser
...Show More Authors

Breast mass is by far the most important clinical problem that concerns the breast today. This study was carried out to evaluate diode laser as a cutting tool in breast mass excision and as a hemostatic tool for coagulation during surgery. Using 810 nm diode laser with optical fiber 600μm in diameter of conical tip, udder (cow's breast) tissue, and three female patients (mean age of 35.5 y with clinically palpable breast mass) had been used in this study. The patients were followed up regularly postoperatively. In preliminary work on udder tissue, the power needed for cutting and excision was 15W (power density= 5.3 kW/cm2). The time consumed for excision of a piece of udder tissue, 40×10×3 mm in dimensions was 5 min. The depth range

... Show More
View Publication Preview PDF
Publication Date
Tue Dec 30 2014
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Performance Evaluation of Three Phase Spray Direct Contact Heat Exchanger
...Show More Authors

 

The present investigation deals with experimental study of three-phase direct-contact heat exchanger, for water-Freon R11 system, where water is the continuous phase (liquid) and Freon R11 (liquid-gas) is the dispersed phase. The test section consisted of a cylindrical Perspex column with inner diameter 8cm and 1.2m long, in which, water was to be confined. Liquid Freon R11 drops were injected into the hot water filled column, through a special design of distributors at the bottom of the column. The liquid Freon R11 drops rose on their way up and evaporated into two-phase bubbles at atmospheric pressure. The study was devoted to express the effect of process variables such as c

... Show More
View Publication Preview PDF
Publication Date
Sat Nov 01 2025
Journal Name
Kufa Journal Of Engineering
SIMULATION FOR PERFORMANCE EVALUATION OF SATELLITE-BASED QUANTUM COMMUNICATION SYSTEM
...Show More Authors

The selection and assessment of single-photon detection modules is a crucial problem in satellite-based QKD systems. The system's overall efficiency, secure key rate and quantum bit error rate are all significantly influenced by single-photon detection modules. There is a knowledge gap about the practical performance of commercially available single-photon detectors because existing research frequently relies on theoretical characteristics. This paper introduces a study on the effect of the parameters of three commercial single photon detection modules from ID Quantique company: ID Qube, ID100, and ID281 on certain Bennett-Brassard 1984 protocol parameters such as secure key rate, mean photon number per pulse, quantum bit error rate

... Show More
View Publication Preview PDF
Scopus (1)
Crossref (1)
Scopus Crossref
Publication Date
Mon Jun 03 2019
Journal Name
Journal Of Global Pharma Technology
New Diquinazoline Derivatives: Synthesis and Evaluation of AntiBacterial Activi
...Show More Authors

Oxazine and quinazoline has a very important in organic chemistry especially in hetero cyclic fields. this research consist the preparation of 4H,4'H-2,2'-bibenzo[d][1,3]oxazine-4,4'-dione compound (1) from di acid chloride with 2-aminobenzoic acid in pyridine as solvent to give compound (2) 3,3'-diamino-2,2'- biquinazoline-4,4'(3H,3'H)-dione .compound 2 include free amino group .this compound was reacted with maleic and phthalic anhydride for synthesized of cyclic imide compounds (3,4).another reaction for compound 2 with some substituted aromatic aldehyde for prepared of some novel Schiff bases (5-9) contains quinazoline ring. compound 1 was treated with sulfathiazole and sulfadiazine for synthesized of sulfa compounds contains sulf

... Show More
View Publication Preview PDF
Publication Date
Sun Nov 02 2014
Journal Name
Iraqi Journal Of Pharmaceutical Science
preparation and evaluation of meloxicam microsponges as transdermal delivery system
...Show More Authors

Publication Date
Thu Jun 16 2022
Journal Name
Clean Technologies
Performance Evaluation of Roughened Solar Air Heaters for Stretched Parameters
...Show More Authors

Crossref (5)
Crossref
Publication Date
Sat Apr 11 2009
Journal Name
Journal Of Kerbala University
Evaluation The Behaviour of Reinforced Loose Sand under Inclined Loading
...Show More Authors

Publication Date
Wed Dec 11 2019
Journal Name
Journal Of The College Of Education For Women
Evaluation of Raw and Drinking Water for Diyala Governorate (2017)
...Show More Authors

The study examined the assessment of raw water and drinking water projects of  Diyala Governorate for the year 2017, amounting to (24) projects, The average per capita supply of potable water (0.396 m3 / day/person), which is less than the global standard for the average per capita of drinking water, and constitute water rumors within the network of water transport in the province (3%), and the water of raw and drinking value within the limits allowed to be used by Iraq and the global indicators of {Total acidity, alkaline, acidic function, chlorides, magnesium, Electrical conductivity, total soluble salts, sodium, potassium, sulfates, turbidity other than (raw water)}. While the index of calcium only a value higher than the limits

... Show More
View Publication Preview PDF