ABSTRACT: BACKGROUND: The main goal of facelift surgery is to reduce the effect of aging by reposition of face soft tissue in to more youthful orientation. There are many methods for SMAS plication which had different design and vector of pull. AIM OF STUDY: To evaluate the effectiveness and longitivity of 7 shaped SMAS plication in facelift. PATIENT AND METHODS: From January 2020 to march 2021, 10 female patients with age (45-60) years were presented with facial sagging, those patients were subjected to subcutaneous facelift with 7 shaped SMAS plication with fat greft in Al-Shaheed Ghazi Al-Harri Hospital and Baghdad burn medical center at Baghdad medical complex. RESULTS: The average follow up period was 6 to 12 months. The mean operative time was 1 hour and 30 minutes. Additional facial procedures were later done which including: fat injection (all patients), brow lift (one patient), facial scar subcision with fat grafting (one patient) and sub mental liposuction with platysma plication (2 patient). All of our patients demonstrate high level of subjective satisfaction with quick recovery with no major or minor complications CONCLUSION: The subcutaneous facelift with 7 shaped SMAS plication is simple to learn with high patients satisfaction and long lasting result.
Abstract To ensure that the distribution system has safe drinking water. It is necessary to know the residual chlorine concentrations at various points in the network. A chlorine photometer device was used to measure twenty points taken every day for a week at a selected time in the distribution system. Both pressures and flows in the network were measured using bourdon gauge and Tuf-2000H Handheld Digital ultrasonic flow meters. WaterGEMS CONNECT Edition update one software was used to simulate the flow in the network. The Baghdad water department provided the data about the network, such as the lengths of pipes, the layout of the network, and pipes diameters. The network calibrated consists of 781 pipes of different lengths and 542 juncti
... Show MoreBackground: The bond strength of the root canal sealers to dentin seems to be a very important property for maintaining the integrity and the seal of root canal filling. The aim of this study was to evaluate the shear bond strength of four different obturation systems using push-out test. Materials and methods: Forty straight palatal roots of the maxillary first molars teeth were used in this study, these roots were instrumented using crown down technique and ProTaper system, instrumentation were done with copious irrigation of 2.5% sodium hypochlorite and 17% buffered solution of EDTA was used as final irrigant followed by distilled water, roots were randomly divided into four groups according to the obturation system (ten teeth for each g
... Show MoreThe current study aimed to detect the effect of gentamicin stress on the expression of hla (encodes hemolysin) and nuc (encodes nuclease) genes of Staphylococcus aureus. Fifty-eight isolates identified as S. aureus were isolated locally from different clinical specimens. Disk diffusion method was used to detect the resistance to S. aureus. The minimum inhibitory concentration (MIC) of gentamicin was estimated by broth microdilution method. hla and nuc genes were determined by polymerase chain reaction technique. The biofilm was evaluated using the microtiter plate method in the presence and absence of gentamicin at sub-MIC. The results showed that 18 (31%) and 40 (69%) S. aureus isolates were sensitive and resistant to gentamicin, respectiv
... Show More