Background: Stroke defined by diminished cerebral blood flow, results in brain damage and neurological impairments. It often leads to considerable difficulties, such as limited mobility and compromised hand function, usually manifesting as a weakening in the ability to open and shut the hand. Objective: The study evaluates the differences between opening and closing hands when utilizing a soft robot. Methods: The study was conducted in the Mosul Specialist Rehabilitation Center which involved 68 participants, all over 20 years old, with visual impairments. The Iranian Clinical Trials Registry and Ministry of Planning approved the study, The Fugl-Meyer Assessment for Upper Extremity Action Research Arm Test, and Arm Motor Ability Test were used to assess finger extension and flexion. Results: A study revealed that stroke patients who utilized a soft robotic glove experienced notable improvements in hand functionality. Average hand closure scores increased significantly, from 8.14 to 20.36 out of 21 points. Women demonstrated greater progress in hand opening rates compared to men, with an average improvement of 1.91 times between pre- and post-assessments. In contrast, the control group exhibited similar hand-opening advancements across genders. Patients with both ischemic and hemorrhagic strokes showed enhanced abilities in opening and closing their hands. Additionally, the study identified a statistically significant improvement in hand function improvements based on stroke type. Conclusion: The study found that stroke patients using a soft robotic glove showed significant improvements in hand-closing abilities, while exercise had minimal impact. Women showed an average increase in hand opening rate. Both male and female patients showed improvement, with hemorrhagic strokes showing remarkable advancements.
The performance of photovoltaic (PV) panel having staggered metal foam fins was examined experimentally in Baghdad, Iraq. Three staggered metal foam fin configurations attached to the backside of the PV panel were studied. The measured parameters were front and back surfaces temperature, open voltage and current circuits, maximum power, and PV efficiency. It was noted that the maximum electrical efficiency enhancement was 4.7% for staggered metal foam fins (case III) than the reference PV panel. The operating temperature of the cell was increased when the value of solar intensity was high. Thereby, the electrical efficiency was decreased. It was found that the metal foam fins decreased the PV temperature by 2-3 o
... Show MoreThe experiment was carried out in College of Agricultural Engineering Sciences, University of Baghdad during November 1, 2019 to June 1, 2020. The experiment was designed according to a randomized complete block design. Each block contained 18 experimental units that included the three study factors. The first factor interaction between two inoculum densities and application methods, three levels control, treatment of seeds inoculation with 5g plant and treatment of seedlings inoculation whith 30g plant . The second factor was three -1 -1concentrations of spraying of kinetin 0, 75 and 150 mg L , and third factor include two levels of organic manure) and addition of fertilizer 2% of -1 the weight of the soil (O2). The results showed a signif
... Show MoreCadmium sulfide (CdS) thin films with n-type semiconductor characteristics were prepared by flash evaporating method on glass substrates. Some films were annealed at 250 oC for 1hr in air. The thicknesses of the films was estimated to be 0.5µ by the spectrometer measurement. Structural, morphological, electrical, optical and photoconductivity properties of CdS films have been investigated by X-ray diffraction, AFM, the Hall effect, optical transmittance spectra and photoconductivity analysis, respectively. X-ray diffraction (XRD) pattern shows that CdS films are in the stable hexagonal crystalline structure. Using Debye Scherrerś formula, the average grain size for the samples was found to be 26 nm. The transmittance of the
... Show Moreabstract
the research discussed a stage of strategic management. The strategic of the evaluation of the proposed strategy through feedback is to ensure that it is implemented with the least possible variation. The research aims at evaluation a proposed strategy for the Ministry of Planning for the years 2018-2022 in line with the orientations of the state, taking into account the surrounding environmental conditions. It relies on scientific bases and steps to formulate the strategy The extent of the strategy suitability was tested through a set of statistical means and its objectivity was verified through a survey of a number of specialized experts who were selected in accordance with the principle
... Show MoreBackground: Lack of durability of the bond of the dental adhesive systems to tooth structure is one of the most important problems in tooth colored restorative work. This in vitro study was performed to evaluate the effect of 2% chlorhexidine gluconate(CHX) on dentin bond strength by using total etch adhesive system at twenty-four hours and three months of water storage. Material and methods:A flat dentin surface was prepared for forty sound human maxillary premolar teeth which were acid etched with 36% phosphoric acid gel after being divided randomly into four groups of ten teeth each according to storage time and CHX application, theCHX was applied for 60 seconds before adhesive application for groups I and III which were tested after twe
... Show MoreY Adnan, H Atiyah, IH Neamah…, International Development Planning Review, 2024
Background: Currently there are four general approaches to correct refractive errors: refractive corneal surgery, crystalline lens surgery and implantation of an intraocular lens in anterior or posterior chamber.
Objective: To evaluate the predictability, safety and stability of toric phakic implantable collamer lens implantation to correct moderate to high myopic astigmatism. in Eye Specialty Private Hospital, Baghdad, Iraq.
Type of the Study: a prospective non randomize intervention study.
Methods: 60 eyes of 40 patients underwent implantation of a toric implantable collamer lens (V4c design).Mean spherical refraction was ₋11.32 diopter
... Show MoreBackground: Currently there are four general approaches to correct refractive errors: refractive corneal surgery, crystalline lens surgery and implantation of an intraocular lens in anterior or posterior chamber. Aim: To evaluate the predictability, safety and stability of toric phakic implantable collamer lens implantation to correct moderate to high myopic astigmatism. Methods: Sixty eyes of 40 patients underwent implantation of a toric implantable collamer lens (V4c design) in the Eye Specialty Private Hospital, Baghdad, Iraq were studied. The mean spherical refraction was -11.32±3.17 diopter (D) with a range of -6.00 to -18.00 D and a mean cylinder of -2.61±1.16 with range of -1.00 to -5.50 D. The outcome measures that evaluat
... Show More