Preferred Language
Articles
/
TGEtKJkBdMdGkNqjtRTD
Enhancement of the Blood Glucose Level for Diabetic Patients Based on an Adaptive Auto-Tuned PID Controller via Meta-Heuristic Methods
...Show More Authors

Scopus Crossref
View Publication
Publication Date
Sun Jun 01 2014
Journal Name
Baghdad Science Journal
The effect of Glycated Haemogloin A1c and Fasting Blood Glucose in Type1 Diabetes
...Show More Authors

The glycated haemoglobin A1c(HbA1c) and Fasting blood glucose(FBG) effect on type1 diabetic pateints as a screening tests and as a gold standard for assessing glycemic control in subjects with diabetes were studied . Ninety one blood samples were collected in a peroid between June and the end of November 2012 at AL- Kindy Diabetic Center and Central Child Hospital,48 Females and 43 Males , aging between (11 month- 18 year), are divided into three groups, newly diagnosed , ongoing and healthy control group, with duration of disease between(1 day-3months) and (from birth-8 years) for newly diag

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Mon Jun 19 2017
Journal Name
Arabian Journal For Science And Engineering
A New Method to Tune a Fractional-Order PID Controller for a Twin Rotor Aerodynamic System
...Show More Authors

View Publication
Scopus (33)
Crossref (29)
Scopus Clarivate Crossref
Publication Date
Sun Dec 03 2023
Journal Name
2023 Ieee International Conference On Energy Technologies For Future Grids (etfg)
Optimal Hybrid Type-2 Fuzzy-PID Controller for Blade Pitch Angle in Horizontal-axis Wind Turbines
...Show More Authors

In the modern world, wind turbine (WT) has become the largest source of renewable energy. The horizontal-axis wind turbine (HAWT) has higher efficiency than the vertical-axis wind turbine (VAWT). The blade pitch angle (BPA) of WT is controlled to increase output power generation over the rated wind speed. This paper proposes an accurate controller for BPA in a 500-kw HAWT. Three types of controllers have been applied and compared to find the best controller: PID controller (PIDC), fuzzy logic type-2 controller (T2FLC), and hybrid type-2 fuzzy-PID controller (T2FPIDC). This paper has been used Mamdani and Sugeno fuzzy inference systems (FIS) to find the best inference system for WT controllers. Furthermore, genetic algorithm (GA) and particl

... Show More
View Publication
Scopus (3)
Crossref (2)
Scopus Crossref
Publication Date
Sun Mar 04 2012
Journal Name
Baghdad Science Journal
C-Reactive Protein and Cholesterol level In Male Type 2 Diabetic Patients.
...Show More Authors

Elevated C-Reactive Protein (CRP) level in serum is a risk factor for type 2 diabetes ,this relationship is likely to be the cause it means elevated CRP leads to T2D in future . Our objective was to examine CRP in male Type 2 Diabetes(T2D) patients in different age ,we studied 120 male subjects divided to two groups according to their age. First group A age (31 - 40) year old ,60 person )30 control & 30 T2D patients(,3 person for each same age: second group B age (41 – 50) years old ,60 person )30 control & 30 T2D patients(,3 person for each same age. We examined blood sugar ,cholesterol and CRP in each group. and we toke the mean of samples in the same age in each data in all the 4 groups. Our data shows that CRP

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Mar 26 2017
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
The Effect of L-Carnitine as an Adjuvant Supplement on Lipid Profile in Iraqi Diabetic Patients
...Show More Authors

Diabetes is a complex set of diseases require continuous medical care, to control blood sugar and prevent complications is .The aim of this research is to determine the effect of administration of   L carentin to diabetics on the   lipid profile. The research was conducted on sixty diabetic patients were selected from endocrinology and diabetes center / Al-Rusafa, within selected criteria. The patients divided into 3 groups (control group of healthy people and two groups of patients with diabetes who were on metformin and glibenclamide, one group took a L  carnitine in a dose of 1000 mg twice daily and a group dealing with a placebo for a period of 3 months continuously). The study found that patients who took Lc

... Show More
View Publication Preview PDF
Crossref
Publication Date
Wed Dec 13 2017
Journal Name
Al-khwarizmi Engineering Journal
Performance Comparison of Different Advanced Control Schemes for Glucose Level Control under Disturbing Meal
...Show More Authors

Abstract

In this work, diabetic glucose concentration level control under disturbing meal has been controlled using two set of advanced controllers. The first set is sliding mode controllers (classical and integral) and the second set is represented by optimal LQR controllers (classical and Min-, ax). Due to their characteristic features of disturbance rejection, both integral sliding mode controller and LQR Minmax controller are dedicated here for comparison. The Bergman minimal mathematical model was used to represent the dynamic behavior of a diabetic patient’s blood glucose concentration to the insulin injection. Simulations based on Matlab/Simulink, were performed to verify the performance of each controll

... Show More
View Publication Preview PDF
Crossref
Publication Date
Fri Jan 01 2021
Journal Name
Fme Transactions
FAT-based adaptive backstepping control of an electromechanical system with an unknown input coefficient
...Show More Authors

This paper is focused on orthogonal function approximation technique FAT-based adaptive backstepping control of a geared DC motor coupled with a rotational mechanical component. It is assumed that all parameters of the actuator are unknown including the torque-current constant (i.e., unknown input coefficient) and hence a control system with three motor control modes is proposed: 1) motor torque control mode, 2) motor current control mode, and 3) motor voltage control mode. The proposed control algorithm is a powerful tool to control a dynamic system with an unknown input coefficient. Each uncertain parameter/term is represented by a linear combination of weighting and orthogonal basis function vectors. Chebyshev polynomial is used

... Show More
View Publication
Scopus (6)
Crossref (7)
Scopus Clarivate Crossref
Publication Date
Thu Jan 13 2022
Journal Name
Medical & Biological Engineering & Computing
An integrated entropy-spatial framework for automatic gender recognition enhancement of emotion-based EEGs
...Show More Authors

View Publication
Scopus (12)
Crossref (13)
Scopus Clarivate Crossref
Publication Date
Mon Apr 01 2019
Journal Name
Journal Of Engineering
Design of New Hybrid Neural Controller for Nonlinear CSTR System based on Identification
...Show More Authors

This paper proposes improving the structure of the neural controller based on the identification model for nonlinear systems. The goal of this work is to employ the structure of the Modified Elman Neural Network (MENN) model into the NARMA-L2 structure instead of Multi-Layer Perceptron (MLP) model in order to construct a new hybrid neural structure that can be used as an identifier model and a nonlinear controller for the SISO linear or nonlinear systems. Two learning algorithms are used to adjust the parameters weight of the hybrid neural structure with its serial-parallel configuration; the first one is supervised learning algorithm based Back Propagation Algorithm (BPA) and the second one is an intelligent algorithm n

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Tue Jan 01 2008
Journal Name
Journal Of Engineering
USING FUZZY LOGIC CONTROLLER FOR A TWO- TANK LEVEL CONTROL SYSTEM
...Show More Authors

This paper presents a fuzzy logic controller for a two-tank level control system, which is a process with a dead time. The fuzzy controller is a proportional-integral (PI-like) fuzzy controller which is suitable for steady state behavior of the system. Transient behavior of the system was improved without the need for a derivative action by suitable change in the rule base of the controller. Simulation results showed the step response of the two-tank level control system when this controller was used to control this plant and the effect of the dead time on the response of the system.