Preferred Language
Articles
/
ShdYspIBVTCNdQwCzr6m
Evaluation of using double Teostrut graft to control naral tip projection
...Show More Authors

Abstract Background: Dne of the key component of nasal tipplasty is effecter control of naral tip projection. Several cartilage grafts have been decreased for this purpose each had its own advantage and disadvantage. Aim: To evaluate using of double teostrut graft for controlling of tip projection. Patients and Methods: A total number of 170 patients were subjected to primary and secondary rhino plaster between January 2020 to January 2023. Those patients had double Teostrut banner graft for support of their nasal tip and maintaining tip projection after operation. Results: The follow period was ranging between 6-12 months. The shape of the nose was evaluating by patents vernal analogues scale. The average score for patients satisfaction was 8.2 out of 10 points which indicated high satisfaction rate. Conclusion: Our current approach using double Teostrut graft showed to be effective and predicted in maintaining of tip projection after operation using of double teostrut graft avoid potential complications that might be associated with single teostrut graft which namely rotation and distraction of graft which may lead to droop lay and lateralization nasal tip.

Publication Date
Wed Feb 01 2023
Journal Name
Journal Of Engineering
Double-Staged Syndrome Coding Scheme for Improving Information Transmission Security over the Wiretap Channel
...Show More Authors

This paper presents a study of a syndrome coding scheme for different binary linear error correcting codes that refer to the code families such as BCH, BKLC, Golay, and Hamming. The study is implemented on Wyner’s wiretap channel model when the main channel is error-free and the eavesdropper channel is a binary symmetric channel with crossover error probability (0 < Pe ≤ 0.5) to show the security performance of error correcting codes while used in the single-staged syndrome coding scheme in terms of equivocation rate. Generally, these codes are not designed for secure information transmission, and they have low equivocation rates when they are used in the syndrome coding scheme. Therefore, to improve the transmiss

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Mar 01 2020
Journal Name
Baghdad Science Journal
A Comparative Study on the Double Prior for Reliability Kumaraswamy Distribution with Numerical Solution
...Show More Authors

This work, deals with Kumaraswamy distribution. Kumaraswamy (1976, 1978) showed well known probability distribution functions such as the normal, beta and log-normal but in (1980) Kumaraswamy developed a more general probability density function for double bounded random processes, which is known as Kumaraswamy’s distribution. Classical maximum likelihood and Bayes methods estimator are used to estimate the unknown shape parameter (b). Reliability function are obtained using symmetric loss functions by using three types of informative priors two single priors and one double prior. In addition, a comparison is made for the performance of these estimators with respect to the numerical solution which are found using expansion method. The

... Show More
View Publication Preview PDF
Scopus (3)
Crossref (1)
Scopus Clarivate Crossref
Publication Date
Sat Nov 01 2014
Journal Name
International Journal Of Statistics
Single and Double Stage Shrinkage Estimators for the Normal Mean with the Variance Cases
...Show More Authors

View Publication
Publication Date
Sun Jul 01 2018
Journal Name
International Journal Of Engineering Research And Management
The first and Second Order Polynomial Models with Double Scalar Quantization for Image Compression
...Show More Authors

Publication Date
Sun Apr 08 2018
Journal Name
Al-khwarizmi Engineering Journal
Experimental Investigation of the Effect of Curvature Ratio on Heat Transfer in Double Pipe Helical Heat Exchanger
...Show More Authors

Different parameters of double pipe helical coil were investigation experimentally. Four coils were used; three with a curvature ratio (0.037, 0.031, and 0.028) and 11mm diameter of the inner tube while the fourth with 0.033 curvature ratio and 13 mm diameter of the inner tube. The hot water flow in the inner tube whereas the cold water flows in the annulus. The inlet temperatures of hot and cold water are 50 0C and 18 0C respectively. The inner mass flow rate ranges from 0.0167 to 0.0583 kg/s. The results show the Nusselt number increase with increase curvature ratio. The Nusselt number of the coil with 0.037 curvature ratio increases by approximately 12.3 % as compare with 0.028 curvature ratio. The results also r

... Show More
View Publication Preview PDF
Crossref
Publication Date
Fri Mar 01 2024
Journal Name
Al-khwarizmi Engineering Journal
Control System Development of Cap-Seal Assembling Machine
...Show More Authors

   

View Publication
Scopus Crossref
Publication Date
Sat Dec 02 2017
Journal Name
Al-khwarizmi Engineering Journal
Fuzzy control of mobile robot in slippery environment
...Show More Authors

 

The problem of independent motion control of mobile robot (МR) in conditions when unforeseen changes of conditions of interaction of wheels with a surface are considered. An example of such changes can be sudden entrance МR a slippery surface. The deployment of an autonomous unmanned ground vehicle for field applications provides the means by which the risk to personnel can be minimized and operational capabilities improved. In rough terrain, it is critical for mobile robots to maintain good wheel traction. Wheel slip could cause the rover to lose control and become trapped. This paper describes the application of fuzzy control to a feedback system within slippery environment. The study is conducted on an example of М

... Show More
View Publication Preview PDF
Publication Date
Fri Sep 01 2023
Journal Name
Journal Of Engineering
EMG-Based Control of Active Ankle-Foot Prosthesis
...Show More Authors

 Most below-knee prostheses are manufactured in Iraq without considering the fast progress in smart prostheses, which can offer movements in the desired directions according to the type of control system designed for this purpose. The proposed design appears to have the advantages of simplicity, affordability, better load distribution, suitability for subjects with transtibial amputation, and viability in countries with people having low socio-economic status. The designed prosthetics consisted of foot, ball, and socket joints, two stepper motors, a linkage system, and an EMG shield. All these materials were available in the local markets in Iraq. The experimental results showed t

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Wed Dec 29 2021
Journal Name
Al-khwarizmi Engineering Journal
Analysis of Magnetorheological Normally Close Directional Control Valve
...Show More Authors

This valve is intended for use in valves for steering movement, using the qualities of the Magneto-rheological (MR) fluid to regulate the fluid, direct contact without the utilization of moving parts like a spool, a connection between electric flux, and fluid power was made, The simulation was done to employ the" finite element method of magnetism (FEMM)" to arrive at the best design. This software is used for magnetic resonance valve finite element analysis. The valve's best performance was obtained by using a closed directional control valve in the normal state normally closed (NC) MR valve, with simulation results revealing the optimum magnetic flux density in the absence of a current and the shedding condition, as well as the optimum pr

... Show More
Preview PDF
Publication Date
Sun May 20 2018
Journal Name
Romansy 22 – Robot Design, Dynamics And Control
Decentralized Adaptive Partitioned Approximation Control of Robotic Manipulators
...Show More Authors

View Publication
Scopus (6)
Crossref (4)
Scopus Crossref