Preferred Language
Articles
/
SRbfj4oBVTCNdQwCR59o
Toward a Minimal sEMG Setup for Knee and Ankle Kinematic Estimation during Gait
...Show More Authors

Scopus Clarivate Crossref
View Publication
Publication Date
Sun Dec 31 2017
Journal Name
Al-khwarizmi Engineering Journal
Solving the Inverse Kinematic Equations of Elastic Robot Arm Utilizing Neural Network
...Show More Authors

The inverse kinematic equation for a robot is very important to the control robot’s motion and position. The solving of this equation is complex for the rigid robot due to the dependency of this equation on the joint configuration and structure of robot link. In light robot arms, where the flexibility exists, the solving of this problem is more complicated than the rigid link robot because the deformation variables (elongation and bending) are present in the forward kinematic equation. The finding of an inverse kinematic equation needs to obtain the relation between the joint angles and both of the end-effector position and deformations variables. In this work, a neural network has been proposed to solve the problem of inverse kinemati

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Wed Jun 27 2018
Journal Name
Iraqi Journal Of Science
Accurate Three Dimensional Coordinates Measurements Using Differential GPS Real Time Kinematic Mode
...Show More Authors

The accurate 3-D coordinate's measurements of the global positioning systems are essential in many fields and applications. The GPS has numerous applications such as: Frequency Counters, Geographic Information Systems, Intelligent Vehicle Highway Systems, Car Navigation Systems, Emergency Systems, Aviations, Astronomical Pointing Control, and Atmospheric Sounding using GPS signals, tracking of wild animals, GPS Aid for the Blind, Recorded Position Information, Airborne Gravimetry and other uses. In this paper, the RTK DGPS mode has been used to create precise 3-D coordinates values for four rover stations in Baghdad university camp. The HiPer-II Receiver of global positioning system was used to navigate the coordinate value. The results wil

... Show More
View Publication Preview PDF
Scopus (3)
Scopus Crossref
Publication Date
Thu Sep 24 2020
Journal Name
F1000research
Characterization of flow cytometric immuno-phenotyping of acute myeloid leukemia with minimal differentiation and acute T-cell lymphoblastic leukemia: A retrospective cross-sectional study
...Show More Authors

Background: Acute leukemias (ALs) are a heterogeneous group of malignancies with various clinical, morphological, immunophenotypic, and molecular characteristics. Distinguishing between lymphoid and myeloid leukemia is often performed by flow cytometry. This study aimed to evaluate the immunophenotypic characterization and expression of immuno-markers in both acute myeloid leukemia (AML-M0) and acute T-cell lymphoblastic leukemia (T-ALL).

Methods: A retrospective cross-sectional study was conducted in the Pathology Department/Teaching Laboratories/Medical City/Iraq and included all patients newly diagnosed with AL from 5 January to 10 December 2018. Immunophenotypic analysis wa

... Show More
View Publication
Scopus Crossref
Publication Date
Tue Jun 30 2015
Journal Name
Al-kindy College Medical Journal
Magnetic resonance imaging findings of knee injury
...Show More Authors

Background: Since its introduction to musculoskeletal imaging in the early 1980, magnetic resonance imaging (MRI) has revolutionized diagnostic imaging of the knee. It is therefore become the examination of choice in the evaluation of internal joint structures of the knee like menisci, cruciate ligaments, and articular cartilage.Objectives: to describe the MRI finding in various knee injuries.Patients and methods: A cross sectional study was done on 130 patients with history of knee injury in MRI unit at institute of radiology and al-Shaheed Ghazi Al-Hariri Hospital in medical city complex - Baghdad, from October 2011 to February 2013 includes 103 men, 27 women; the mean age was 33.86 years. MR imaging studies of the knee performed using

... Show More
View Publication Preview PDF
Publication Date
Fri Mar 14 2025
Journal Name
Wasit Journal Of Sports Sciences
The effect of RTX traning and plastic hurdles on some kinematic variables and learning the performance of the event of 100 mH for female students
...Show More Authors

View Publication
Publication Date
Fri Jan 01 2016
Journal Name
International Archives Of Medicine
The role of MRI in the diagnosis of intra articular knee derangement: A prospective study
...Show More Authors

View Publication Preview PDF
Crossref
Publication Date
Thu Feb 01 2018
Journal Name
International Journal Of Pharmacy And Pharmaceutical Sciences
IMPACT OF METFORMIN AND SERRATIOPEPTIDASE IN OBESE PATIENTS WITH KNEE OSTEOARTHRITIS
...Show More Authors

Objective: Knee osteoarthritis is a common disabling chronic disease globally. Many pharmacological agents have been used efficiently in treatment of knee osteoarthritis. This study aims to evaluate metformin and serratiopeptidase together in treatment and stop of osteoarthritis progression by different mechanisms. Methods: Present study was a randomized clinical trial study conducted in Al-Kindi teaching hospital through the period from 1st January to 30th of May, 2017 on two groups of 80 osteoarthritis patients (group I; treated with metformin 850 mg oral tablets) and (group II; treated with metformin 850 mg oral tablets and serratiopeptidase 20 mg oral tablets). Parameters of two groups were compared with those of 40 normal healt

... Show More
View Publication Preview PDF
Crossref (4)
Crossref
Publication Date
Thu Sep 12 2019
Journal Name
Al-kindy College Medical Journal
Minimal sternotomy surgery in comparison to standard sternotomy in the coronary bypass Surgery
...Show More Authors

Background Median sternotomy is the gold standard incision for most cardiac operations. However, with the advent of minimal invasive surgery, a new approach emerged in cardiac surgery named mini-sternotomy and has been successfully used to perform a variety of operations.

 The aim of this paper is to present our experience of using mini-sternotomy to harvest the left internal mammary artery (LIMA) for off-pump revascularization of the left anterior descending artery (LAD)

 Methodology Over a 2-year period (October 2012-October 2014), 100 patients underwent coronary artery bypass grafting (CABG) via conventional median sternotomy (CMS) (n=80) and mini-sternotomy (MS) (n=20). The

... Show More
View Publication Preview PDF
Crossref
Publication Date
Fri Mar 01 2013
Journal Name
Journal Of Economics And Administrative Sciences
Comparison for estimation methods for the autoregressive approximations
...Show More Authors

Abstract

      In this study, we compare between the autoregressive approximations (Yule-Walker equations, Least Squares , Least Squares ( forward- backword ) and Burg’s (Geometric and Harmonic ) methods, to determine the optimal approximation to the time series generated from the first - order moving Average non-invertible process, and fractionally - integrated noise process, with several values for d (d=0.15,0.25,0.35,0.45) for different sample sizes (small,median,large)for two processes . We depend on figure of merit function which proposed by author Shibata in 1980, to determine the theoretical optimal order according to min

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Mar 03 2013
Journal Name
Baghdad Science Journal
A Comparison of the Methods for Estimation of Reliability Function for Burr-XII Distribution by Using Simulation.
...Show More Authors

This deals with estimation of Reliability function and one shape parameter (?) of two- parameters Burr – XII , when ?(shape parameter is known) (?=0.5,1,1.5) and also the initial values of (?=1), while different sample shze n= 10, 20, 30, 50) bare used. The results depend on empirical study through simulation experiments are applied to compare the four methods of estimation, as well as computing the reliability function . The results of Mean square error indicates that Jacknif estimator is better than other three estimators , for all sample size and parameter values

View Publication Preview PDF
Crossref