Preferred Language
Articles
/
SIaAiIYBIXToZYALI40t
Esterification Reaction Kinetics Using Ion Exchange Resin Catalyst by Pseudo-Homogenous and Eley-Ridel Models
...Show More Authors

This work deals with kinetics and chemical equilibrium studies of esterification reaction of ethanol with acetic acid. The esterification reaction was catalyzed by an acidic ion exchange resin (Amberlyst- 15) using a batch stirred tank reactor. The pseudo-homogenous and Eley-Rideal models were successfully fitted with experimental data. At first, Eley-Rideal model was examined for heterogeneous esterification of acetic acid and ethanol. The pseudo-homogenous model was investigated with a power-law model. The apparent reaction order was determined to be (0.88) for Ethanol and (0.92) for acetic acid with a correlation coefficient (R2) of 0.981 and 0.988, respectively. The reaction order was determined to be 4.1087x10-3 L0.8/(mol0.8.min) with R2 of 0.954. The adsorption constants of acetic acid and ethanol were calculated as 0.023 and 0.044 L/mol, respectively and the lumped reaction constant were determined to be 5*10-4 L2/gcat.mol.min. The results of the reaction kinetic study show that the high acetic acid/ethanol molar ratio was favored. The maximum conversion of 70 % was obtained at 70°C for acetic acid/ethanol molar ratio of 4.

Scopus Clarivate Crossref
Publication Date
Fri Dec 30 2022
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Mathematical Modeling and Kinetics of Removing Metal Ions from Industrial Wastewater
...Show More Authors

The study's objective is to produce Nano Graphene Oxide (GO) before using it for batch adsorption to remove heavy metals (Cadmium Cd+2, Nickel Ni+2, and Vanadium V+5) ions from industrial wastewater. The temperature effect (20-50) °C and initial concentration effect (100-800) mg L-1 on the adsorption process were studied. A simulation aqueous solution of the ions was used to identify the adsorption isotherms, and after the experimental data was collected, the sorption process was studied kinetically and thermodynamically. The Langmuir, Freundlich, and Temkin isotherm models were used to fit the data. The results showed that Cd, Ni, and V ions on the GO adsorbing surface matched the Langmuir mo

... Show More
View Publication Preview PDF
Crossref (4)
Crossref
Publication Date
Sun Sep 02 2012
Journal Name
Baghdad Science Journal
Batch and Flow-Injection Spectrophotometric Determination of Procaine HCl in Pharmaceutical Preparations Via Using Diazotization and Coupling Reaction
...Show More Authors

Simple and sensitive batch and Flow-injection spectrophotometric methods for the determination of Procaine HCl in pure form and in injections were proposed. These methods were based on a diazotization reaction of procaine HCl with sodium nitrite and hydrochloric acid to form diazonium salt, which is coupled with chromatropic acid in alkaline medium to form an intense pink water-soluble dye that is stable and has a maximum absorption at 508 nm. A graphs of absorbance versus concentration show that Beer’s law is obeyed over the concentration range of 1-40 and 5-400 µg.ml-1 of Procaine HCl, with detection limits of 0.874 and 3.75 µg.ml-1 of Procaine HCl for batch and FIA methods respectively. The FIA average sample throughput was 70 h-1. A

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Tue Jun 30 2020
Journal Name
Iraqi Journal Of Market Research And Consumer Protection
BUILD AN EFFICIENT INVESTMENT PORTFOLIO USING THE WILLIAM RATIO (EMPIRICAL STUDY) IN IRAQ STOCK EXCHANGE: BUILD AN EFFICIENT INVESTMENT PORTFOLIO USING THE WILLIAM RATIO (EMPIRICAL STUDY) IN IRAQ STOCK EXCHANGE
...Show More Authors

ABSTRACT

            This study aimed to choose top stocks through technical analysis tools specially the indicator called (ratio of William index), and test the ability of technical analysis tools in building a portfolio of shares efficient in comparison with the market portfolio. These one technical tools were used for building one portfolios in 21 companies on specific preview conditions and choose 10 companies for the period from (March 2015) to (June 2017). Applied results of the research showed that Portfolio yield for companies selected according to the ratio of William index indicator (0.0406) that

... Show More
View Publication Preview PDF
Publication Date
Mon Jun 01 2020
Journal Name
Iop Conference Series: Materials Science And Engineering
“Impact of culvature and magnetic force on waveform transition of Pseudo plastic fluid in flexible channel”
...Show More Authors
Abstract<p>Waveform transport of Pseudo plastic fluid in complaint symmetric channel with culvature properties has designed. The efforts of magnetic force, which has applied by radiate direction in the analysis, is considered by using the influence of Hartmann number. Walls properties with slip conditions on velocity distribution as well as stream function are used. The analysis of" heat and mass transfer" has taken into account. More popularized factual constraints known by the convective conditions are applied. The partial differential equations of motion, temperature and concentration is reduced under the simulation of low quantity of wave number and Reynolds number and then transformed to or</p> ... Show More
View Publication
Scopus (1)
Scopus Crossref
Publication Date
Sat Mar 01 2025
Journal Name
Geoenergy Science And Engineering
Empirical model for predicting slug-pseudo slug and slug-churn transitions of upward air/water flow
...Show More Authors

A pseudo-slug flow is a type of intermittent flow characterized by short, frothy, chaotic slugs that have a structure velocity lower than the mixture velocity and are not fully formed. It is essential to accurately estimate the transition from conventional slug (SL) flow to pseudo-slug (PSL) flow, and from SL to churn (CH), by precisely predicting the pressure losses. Recent research has showed that PSL and CH flows comprise a significant portion of the conventional flow pattern maps. This is particularly true in wellbores and pipelines with highly deviated large-diameter gas-condensate wellbores and pipelines. Several theoretical and experimental works studied the behavior of PSL and CH flows; however, few models have been suggested to pre

... Show More
View Publication
Scopus Clarivate Crossref
Publication Date
Mon Feb 04 2019
Journal Name
Iraqi Journal Of Physics
Effect of pyridine and pyridine with substituent on photoluminescence of nanoparticles CdS prepared by liquid –liquid interface reaction
...Show More Authors

Liquid – liquid interface reaction is the method for
preparation nanoparticles (NP'S) which depend on the super
saturation of ions that provide by using the system that consist from
toluene and water, the first one is above the second to obtain
nanoparticles (NP's) CdS at the interface separated between these
two immiscible liquid. The structure properties were characterized by
XRD-diffraction and transmission electron microscopy.
The crystalline size estimate from X-ray diffraction pattern
using Scherer equation to be about 7nm,and by TEM analysis give us
that ananosize is about 5 nm which give a strong comparable with
Bohr radius. Photoluminescence analysis give two emission peak,
the first one around

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Sun Dec 01 2013
Journal Name
Journal Of Al-nahrain University
Spectrophotometric Determination of Ketotifen Drug in Pure form and Pharmaceutical Preparation Using Bromothymol Blue Via Ion-Pair Formation
...Show More Authors

Preview PDF
Crossref
Publication Date
Wed Oct 20 2021
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Polymer Chain Reaction (PCR): Principle and Applications
...Show More Authors

The new, standard molecular biologic system for duplicating DNA enzymatically devoid of employing a living organism, like E. coli or yeast, represents polymerases chain reaction (PCR). This technology allows an exponential intensification of a minor quantity of DNA molecule several times. Analysis can be straightforward with more DNA available.

A thermal heat cycler performs a polymerization chain reaction that involves repeated cycles of heating and cooling the reactant tubes at the desired temperature for each reaction step. A heated deck is positioned on the upper reaction tube to avoid evaporating the reaction mixture (normally volumes range from 15 to 100 l per tube), or an oil layer can be placed on a reaction mixture surfa

... Show More
View Publication Preview PDF
Crossref
Publication Date
Mon Aug 14 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Study of Cross Sections for 10 Li 10 Reaction From Cross Sections of Li a,n) Reaction Using the Reciprocity Theory for the Ground State
...Show More Authors

In this study, light elements Li ,10B for (a,n) and (n,a) reactions
as well as o-particle energy from threshold energy to 10 MeV are
used according to the available data of reaction cross sections. The
more recent cross sections data of (a,n) and (n,a) reactions are
reproduced in fine steps 42 Kev for 10B(n,o) Li in the specified
energy range, as well as cross section (o,n) Values were derived from
the published data of (n,a) as a function of a-energy in the same fine
energy steps by using the principle inverse reactions. This calculation
involves only the ground state of Li OB in the reactions 'Li(a,n) B
B (n,a) Li
Introduction
When two charged nuclei overcome their Coulomb repulsion, a
rearrangement

... Show More
View Publication Preview PDF
Publication Date
Wed Nov 07 2018
Journal Name
Iraqi National Journal Of Nursing Specialties
Evaluation of the Hardness of Cold Cured Acrylic Resin Material by Processing at Different Temperature
...Show More Authors

Objective(s): This study aims to evaluate the hardness of two commercially available cold cured acrylic resin material
(Vertex and PAN) when polymerized at different temperature in comparison to those polymerized by conventional
methods in air at 23C ± 5C.
Methodology: Eighty specimens, forty from cold cured acrylic (Vertex Type) and forty from cold cured acrylic (PAN
type) were prepared, flasking and packing procedure were done according to manufacturer direction and divided
according to processing as follow: 20 specimens (10 from Vertex type and 10 from PAN type) were processed in air for
two hours at 23C ± 5C under press (bench curing) as a control, and 60 specimens (30 from Vertex type and 30 from
PAN type) wer

... Show More
View Publication Preview PDF