Chronic kidney Failure, a progressive disease, includes both medical and biochemical features that damage kidneys and decrease their abilities to work effectively, this disease is characterized by a chronic disorders to both the innate and adaptive immune systems, generate a complex and not fully understood immune dysfunction. In the present study, (30) men suffering from chronic kidney failure with age in range (40-55) year and (30) healthy men within the same range of age were enrolled in this study. The aim of this study is to highlight the role of immunological aspect (IL-35), hormonal aspects (PTH), some functional proteins and immunological electrolytes in sera of chronic kidney failure (CKF) patients. Biochemical parameters were determined in the sera of both patients and (healthy) control group. Patients enrolled in this study were newly diagnosed, they have not taken any treatment related to any chronic disease. Blood samples were collected and biochemical parameters were measured in Al- Karama teaching hospital in Baghdad (except IL-35 which was determined in the private Al-Ghazalia Laboratory) from April to November 2015. Results have reported that IL-35 level was highly significant increase in sera of chronic kidney failure patients (35.035± 0.025) pg/mL compared with healthy group (23.331±0.031) pg/mL. As well, PTH level was highly significant increased in patients group (235.032±3.841) pg/ml compared with healthy control group (49.96±0.308) pg/mL. Hemoglobin level was highly significant decreased ( 9.696±0.056) g/L in patients with control group (15.332±0.067) g/dL. Determination of IL-35, PTH, Ferritin and Other biochemical. Parameters in sera of Iraqi Men with chronic kidney failure Rasha Zuhair Jasim and Samira Muajed Yaseen 58 Vol: 13 No:2 , April 2017 DOI: http://dx.doi.org/10.24237/djps.1302.151B P-ISSN: 2222-8373 E-ISSN: 2518-9255 Also, ferritin level was highly significant decreased in chronic kidney failure patients (164.0.68±7.818) ng/mL compared with control group (313.56±1.874) ng/mL. Moreover, albumin level was highly significant decreased (3.00±0.020) g/dL in patients compared with control group (4.928±0.039)g/dL. Bicarbonate level was highly significant decreased (17.412±0.117) mmol/L in patients compared with control group (25.044±0.072) mmol/L, sodium level was non significantly increased in patients (138.65±0.288) meq/L compared with control group (135.84±0.144) meq/L, potassium level was highly significant increased in patients group (5.420±0.0186) meq/L compared with healthy control group (4.700±0.113)meq/L, calcium level was highly significant decreased in patients (7.464±0.054) mmol/L compared with control group (9.628±0.614) mmol/L, phosphate level was significantly increased in patients (4.891±0.016) mg/dL compared with control group (4.552±0.014) mg/dL. The present study concludes that IL-35 is a strong biochemical marker for Iraqi men with CKF. Moreover, this study indicated the positive relationship between (PTH, Na+ , K+ , PO4 2- ) and chronic kidney failure, and the negative relationship between (Ferritin, albumin, hemoglobin, HCO3 - ) and chronic kidney failure in Iraq.
The two parameters of Exponential-Rayleigh distribution were estimated using the maximum likelihood estimation method (MLE) for progressively censoring data. To find estimated values for these two scale parameters using real data for COVID-19 which was taken from the Iraqi Ministry of Health and Environment, AL-Karkh General Hospital. Then the Chi-square test was utilized to determine if the sample (data) corresponded with the Exponential-Rayleigh distribution (ER). Employing the nonlinear membership function (s-function) to find fuzzy numbers for these parameters estimators. Then utilizing the ranking function transforms the fuzzy numbers into crisp numbers. Finally, using mean square error (MSE) to compare the outcomes of the survival
... Show MoreAbstract
In this research provide theoretical aspects of one of the most important statistical distributions which it is Lomax, which has many applications in several areas, set of estimation methods was used(MLE,LSE,GWPM) and compare with (RRE) estimation method ,in order to find out best estimation method set of simulation experiment (36) with many replications in order to get mean square error and used it to make compare , simulation experiment contrast with (estimation method, sample size ,value of location and shape parameter) results show that estimation method effected by simulation experiment factors and ability of using other estimation methods such as(Shrinkage, jackknif
... Show MoreBackground: Despite the fact that asthma is a long-term disease that may be treated, many people are unable to control their symptoms due to a lack of knowledge about their condition. The study's purpose was to find out if a pharmacist intervention improved asthma management because of this.
Objective: this study designed to assess the effect of pharmaceutical care on pulmonary functions test.
Method: The study was completed in three months. The patients who were enrolled were divided into two groups: Group 1 consists of 23 asthma patients who were randomly assigned to receive conventional therapy for chronic bronchial asthma based on disease stage and se
... Show MoreA simple, rapid and sensitive spectrophotometric method has been developed for the determination of captopril in aqueous solution. The method is based on reaction of captopril with 2,3-dichloro 1,4- naphthoquinon(Dichlone) in neutral medium to form a stable yellow colored product which shows maximum absorption at 347 nm with molar absorptivity of 5.6 ×103 L.mole-1. cm-1. The proposed method is applied successfully for determination of captopril in commercial pharmaceutical tablets.
This work was conducted to determine the volumetric mass transfer coefficient (Ky.a) infixed bed adsorption using hexane-benzene mixture by adsorption onto a fixed bed of white silica gel. Benzene concentration was measured by gas chromatography. The effect of feed flow rate and initial concentration of benzene in hexane-benzene mixture on the volumetric mass transfer coefficient and on the adsorption capacity of silica gel was investigated.
In general, the volumetric mass transfer coefficient increases with increasing hexane flow rate, and with increasing initial concentration of benzene in the mixture. The ultimate value of (Ky.a) was at 53 ml/min of hexane flow rate with benzene initial concentration of (6.53 wt. %), and it wa
... Show MoreA sensitive spectrofluorimetric method for the determination of glibenclamide in its tablet formulations has been proposed. The method is based on the dissolving of glibenclamide in absolute ethanol and measuring the native fluorescence at 354 nm after excitation at 302 nm. Beers law is obeyed in the concentration of 1.4 to 10 µg.ml-1 of glibenclamide with a limit of detection (LD) of 0.067 µg.ml-1 and a standard deviation of 0.614. The range percent recoveries (N=3) is 94 - 103.
The research focuses on determination of best location of high elevated tank using the required head of pump as a measure for this purpose. Five types of network were used to find the effect of the variation in the discharge and the node elevation on the best location. The most weakness point was determined for each network. Preliminary tank locations were chosen for test along the primary pipe with same interval distance. For each location, the water elevation in tank and pump head was calculated at each hour depending on the pump head that required to achieve the minimum pressure at the most weakness point. Then, the sum of pump heads through the day was determined. The results proved that there is a most economical lo
... Show MoreA UV-Vis spectrophotometry method was developed for the determination of metoclopramide hydrochloride in pure and several pharmaceutical preparations, such as Permosan tablets, Meclodin syrups, and Plasil ampoules. The method is based on the diazotization reaction of metoclopramide hydrochloride with sodium nitrate and hydrochloric acid to yield the diazonium salt, which is then reacted with 3,5-dimethyl phenol in the presence of sodium hydroxide to form a yellow azo dye. Calibration curves were linear in the range from 0.3 to 6.5 µg/mL, with a correlation coefficient of 0.9993. The limits of detection and quantification were determined and found to be 0.18 and 0.61 µg/mL, respectively. Accuracy and precision were also determined b
... Show More