Preferred Language
Articles
/
SBgv35YBVTCNdQwCUIjY
Determination of IL-35, PTH, Ferritin and Other biochemical parameters in sera of Iraqi Men with chronic kidney failure.
...Show More Authors

Chronic kidney Failure, a progressive disease, includes both medical and biochemical features that damage kidneys and decrease their abilities to work effectively, this disease is characterized by a chronic disorders to both the innate and adaptive immune systems, generate a complex and not fully understood immune dysfunction. In the present study, (30) men suffering from chronic kidney failure with age in range (40-55) year and (30) healthy men within the same range of age were enrolled in this study. The aim of this study is to highlight the role of immunological aspect (IL-35), hormonal aspects (PTH), some functional proteins and immunological electrolytes in sera of chronic kidney failure (CKF) patients. Biochemical parameters were determined in the sera of both patients and (healthy) control group. Patients enrolled in this study were newly diagnosed, they have not taken any treatment related to any chronic disease. Blood samples were collected and biochemical parameters were measured in Al- Karama teaching hospital in Baghdad (except IL-35 which was determined in the private Al-Ghazalia Laboratory) from April to November 2015. Results have reported that IL-35 level was highly significant increase in sera of chronic kidney failure patients (35.035± 0.025) pg/mL compared with healthy group (23.331±0.031) pg/mL. As well, PTH level was highly significant increased in patients group (235.032±3.841) pg/ml compared with healthy control group (49.96±0.308) pg/mL. Hemoglobin level was highly significant decreased ( 9.696±0.056) g/L in patients with control group (15.332±0.067) g/dL. Determination of IL-35, PTH, Ferritin and Other biochemical. Parameters in sera of Iraqi Men with chronic kidney failure Rasha Zuhair Jasim and Samira Muajed Yaseen 58 Vol: 13 No:2 , April 2017 DOI: http://dx.doi.org/10.24237/djps.1302.151B P-ISSN: 2222-8373 E-ISSN: 2518-9255 Also, ferritin level was highly significant decreased in chronic kidney failure patients (164.0.68±7.818) ng/mL compared with control group (313.56±1.874) ng/mL. Moreover, albumin level was highly significant decreased (3.00±0.020) g/dL in patients compared with control group (4.928±0.039)g/dL. Bicarbonate level was highly significant decreased (17.412±0.117) mmol/L in patients compared with control group (25.044±0.072) mmol/L, sodium level was non significantly increased in patients (138.65±0.288) meq/L compared with control group (135.84±0.144) meq/L, potassium level was highly significant increased in patients group (5.420±0.0186) meq/L compared with healthy control group (4.700±0.113)meq/L, calcium level was highly significant decreased in patients (7.464±0.054) mmol/L compared with control group (9.628±0.614) mmol/L, phosphate level was significantly increased in patients (4.891±0.016) mg/dL compared with control group (4.552±0.014) mg/dL. The present study concludes that IL-35 is a strong biochemical marker for Iraqi men with CKF. Moreover, this study indicated the positive relationship between (PTH, Na+ , K+ , PO4 2- ) and chronic kidney failure, and the negative relationship between (Ferritin, albumin, hemoglobin, HCO3 - ) and chronic kidney failure in Iraq.

Publication Date
Fri Sep 25 2020
Journal Name
International Journal Of Drug Delivery Technology
Simultaneous Determination of Trace Mefenamic Acid in Pharmaceutical Samples via Flow Injection Fluorometry
...Show More Authors

Mefenamic acid belongs to non-steroidal anti-inflammatory drugs that are used widely for the treatment of analgesia. Our aim from this study is to establish a new assay for the quantitative determination of mefenamic acid (MFA) in the pharmaceutical sample by two sensitive and rapid flow injection-fluorometric methods. A homemade fluorometer was used in fluorescence measurements, which using solid-state laser diode 405 and 532 nm as a source, combined with a continuous flow injection technique. The first method depends on the effect of MFA on calcein blue (CLB) fluorescence at 405 nm. Another method is a study of rhodamine-6G (Rh-6G) fluorescence after adding MFA, and recording at 532 nm. Optimum parameters as fluorescent dye concen

... Show More
View Publication
Scopus (5)
Crossref (4)
Scopus Crossref
Publication Date
Thu Nov 21 2019
Journal Name
Journal Of Engineering
Automatic Determination of Liquid's Interface in Crude Oil Tank using Capacitive Sensing Techniques
...Show More Authors

The petroleum sector has a significant influence on the development of multiphase detection sensor techniques; to separate the crude oil from water, the crude oil tank is used. In this paper, a measuring system using a simple and low cost two parallel plate capacitance sensor is designed and implemented based on a Micro controlled embedded system plus PC to automatically identify the (gas/oil) and (oil/water) dynamic multi-interface in the crude oil tank. The Permittivity differences of two-phase liquids are used to determine the interface of them by measuring the relative changes of the sensor’s capacitance when passes through the liquid’s interface. The experiment results to determine the liquid’s interface is sa

... Show More
View Publication Preview PDF
Crossref
Publication Date
Wed Aug 23 2017
Journal Name
Journal Of Physics G: Nuclear And Particle Physics
Shell closures in Fl superheavy isotopes via determination of alpha decay preformation factor
...Show More Authors

View Publication
Scopus (7)
Crossref (7)
Scopus Clarivate Crossref
Publication Date
Sun Mar 01 2009
Journal Name
Baghdad Science Journal
Determination of Similarity and Variance in Energy and Depositional Environment, the Difference in Diagenesis and the Variance in the Petrophysical Properties of Reservoir Rocks in Zubair Formation , South Iraq
...Show More Authors

Records of two regionalized variables were processed for each of porosity and permeability of reservoir rocks in Zubair Formation (Zb-109) south Iraq as an indication of the most important reservoir property which is the homogeneity , considering their important results in criterion most needed for primary and enhanced oil reservoir .Z and F tests that were calculated for the two above mentioned properties of pair units of Zubair Formation have shown the difference in depositional energy and different diagenesis between units IL and AB , DJ and AB , and the similarity in grains size , sorting degree , depositional environment and pressure gradients between IL and AB units , LS and IL units ; also the difference in the properties above betw

... Show More
View Publication Preview PDF
Crossref
Publication Date
Fri Jun 30 2023
Journal Name
Iraqi Journal Of Science
Assessing the Potentiality of Using CXCL9 as A Predictive Biomarker for Acute and Chronic Toxoplasmosis, and Study the Correlation Between CXCL9, Toxoplasmosis and Thyroid Disorder in These Cases
...Show More Authors

     Background:  Chemokine (C-X-C motif) ligand (CXCL9) has an important role recruiting the T-lymphocytes and immune response after infection by inducing T-cells accumulation around the areas associated with infections. However, this role is poorly known in relation with Toxoplasma gondii infection and also in association with thyroid hormones, which the present study is focused on. Methods: Eighty-seven women were included in this study for the period between September 2021 and February 2022. Blood samples of uninfected healthy pregnant, in addition to aborted and pregnant women infected with toxoplasmosis, were collected. Sera were then obtained and stored at -10°C. Toxo-latex agglutination test was done, followed by detec

... Show More
View Publication
Scopus Crossref
Publication Date
Sat Jun 01 2013
Journal Name
Journal Of Economics And Administrative Sciences
Comparison between some well- Known methods to estimate the parameter of the proposed method of measurement and the reliability of the distribution function with two parameters Rally by simulation
...Show More Authors

 

 

Abstract

            Rayleigh distribution is one of the important distributions used for analysis life time data, and has applications in reliability study and physical interpretations. This paper introduces four different methods to estimate the scale parameter, and also estimate reliability function; these methods are Maximum Likelihood, and Bayes and Modified Bayes, and Minimax estimator under squared error loss function, for the scale and reliability function of the generalized Rayleigh distribution are obtained. The comparison is done through simulation procedure, t

... Show More
View Publication Preview PDF
Crossref
Publication Date
Wed Dec 25 2019
Journal Name
Journal Of Engineering
Link Failure Recovery for a Large-Scale Video Surveillance System using a Software-Defined Network
...Show More Authors

The software-defined network (SDN) is a new technology that separates the control plane from data plane for the network devices. One of the most significant issues in the video surveillance system is the link failure. When the path failure occurs, the monitoring center cannot receive the video from the cameras. In this paper, two methods are proposed to solve this problem.  The first method uses the Dijkstra algorithm to re-find the path at the source node switch. The second method uses the Dijkstra algorithm to re-find the path at the ingress node switch (or failed link).

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Sun Jun 01 2014
Journal Name
Journal Of Economics And Administrative Sciences
Comparing Bayesian methods to estimate the failure probability for electronic systems in case the life time data are not available
...Show More Authors

In this research, we find the Bayesian formulas and the estimation of Bayesian expectation for product system of Atlas Company.  The units of the system have been examined by helping the technical staff at the company and by providing a real data the company which manufacturer the system.  This real data include the failed units for each drawn sample, which represents the total number of the manufacturer units by the company system.  We calculate the range for each estimator by using the Maximum Likelihood estimator.  We obtain that the expectation-Bayesian estimation is better than the Bayesian estimator of the different partially samples which were drawn from the product system after  it checked by the

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Jun 07 2015
Journal Name
Baghdad Science Journal
Flow Injection Spectrophotometric Determination of Thymol using 4-Aminoantipyrine and Copper(II) Nitrate
...Show More Authors

Flow-injection (FI) spectrophotometric method has been developed for the analysis of thymol in pharmaceutical preparations. The method is based on organic coupling reaction between thymol and 4-amino antipyrine in the presence of alkaline medium to form an intense stable red color complex with copper nitrate that has a maximum absorption at 490 nm. Optimum conditions for determination of the drug was investigated .The calibration graph was linear over the range of 5-500 µg.ml-1 of thymol . The limit of detection (LOD) and limit of quantification (LOQ) were 1.81 ?g mL-1 and 3.60 ?g mL-1 respectively .The proposed method was applied satisfactorily to the determination of thymol in mouth wash preparations. The procedure is characterized by

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Sun Jun 06 2010
Journal Name
Baghdad Science Journal
New Method for the Determination of DL-Histidine by FIA and Chemiluminometric Detection
...Show More Authors

This paper present a simple and sensitive method for the determination of DL-Histidine using FIA-Chemiluminometric measurement resulted from oxidation of luminol molecule by hydrogen peroxide in alkaline medium in the presence of DL-Histidine. Using 70?l. sample linear plot with a coefficient of determination 95.79% for (5-60) mmol.L-1 while for a quadratic relation C.O.D = 96.44% for (5-80) mmol.L-1 and found that guadratic plot in more representative. Limit of detection was 31.93 ?g DL-Histidine (S/N = 3), repeatability of measurement was less that 5% (n=6). Positive and negative ion interferances was removed by using minicolume containing ion exchange resin located after injection valve position.

View Publication Preview PDF
Crossref