Preferred Language
Articles
/
SBg9dZUBVTCNdQwCxy61
Kinetic Study and Determination of Some Insecticides in Soil Samples by Ultrasonic Extraction Followed by Gradient HPLC
...Show More Authors

Ultrasonic Extraction method followed by gradient HPLC was carried out for the simultaneous determination of four insecticides are [imidacloprid (Imi), thiamethoxam (Thi), indoxacarb (Ind) and abamectin (Aba)] used to combat the major insect pests in Iraq, whitefly, Dubas Bug, worms fruits as well as to combat the spiders – dream respectively in eco-soil samples. The extraction recovery was in the range of 99.77 to 109.1 %. The dissipation kinetics and residual levels of these insecticides in soil sample was studied under field ecosystem. The half-life of the mix insecticides was determined. The half-life was in range of 0.38 to 4.06 days with the soil samples were brought from the Agricultural Land called Nahrawan located in the south-east of Baghdad. Such these studies contributed to scientific bases to know the behaver the deferent insecticides mixtures form and to determinate the battier dose uses in application. The coefficient variation (C.V %) was less than (14.1%).

Publication Date
Sun Sep 07 2014
Journal Name
Baghdad Science Journal
Optimum conditions for ascorbic acid determination in three Iraqi citrus using HPLC technique
...Show More Authors

A high-performance liquid chromatography method was employed for the quantitative determination of ascorbic acid (AA) which called vitamin C in three types of Iraqi citrus (orange mandarin and aurantium ) and to establish this goal , evaluation of ascorbic acid degradation is so important due to its significant criticality when exposure to ordinary atmospheric conditions. The chromatographic analysis of AA was carried out after their sequential elution with KH2PO4 ( as mobile phase) by reverse-phase HPLC technique with C8 column and UV detection at 214 nm. .Bad resolutions was appeared clearly for C8 column , so another alternative condition were carried out to improve the resolution by replacement of C8 by C18 column .Statistical treat

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Jun 06 2010
Journal Name
Baghdad Science Journal
Study of pollution by heavy elements in some parts of Baghdad
...Show More Authors

The objective of the present work is to measuring the concentration of heavy elements (Pb, Cd, Zn, As) in Baghdad's soil city and indication to the probable sources of pollution as well as comparing the concentration of heavy elements with local and international ranges. The Sampling and analyzing conducted in the present work included ( 15 ) Samples from Baghdad city ( three samples for each location ).The rates of heavy elements in soil samples were as following:. Pb ( 67.5 ) ppm, Cd ( 4.11 ) ppm , Zn ( 77.9 ) ppm , As ( 4.64 ) ppm. According to the results, we find increasing in the concentrations of the heavy elements ( Pb, Cd, Zn ) in soils and decreasing in ( As ).We conclude that the main reason behind the in

... Show More
View Publication Preview PDF
Crossref (5)
Crossref
Publication Date
Mon Aug 01 2022
Journal Name
Telkomnika (telecommunication Computing Electronics And Control)
Dorsal hand veins features extraction and recognition by correlation coefficient
...Show More Authors

View Publication
Scopus (6)
Crossref (1)
Scopus Crossref
Publication Date
Sun Jun 01 2025
Journal Name
Journal Of Physics: Conference Series
Determination of Radioactivity Levels in Some Rice Samples available in the Iraqi Markets Using the system of High-purity Germanium
...Show More Authors
Abstract<p>This study aimed to determine the radioactivity and radiation hazard indicators of rice samples potentially for human consumption. Gamma spectroscopy was used to calculate the specific activity of natural and artificial radionuclides (<sup>238</sup>U, <sup>232</sup>Th, <sup>40</sup>K, and <sup>137</sup>Cs) in local and imported rice samples collected from local markets in Baghdad Governorate, Iraq, in addition to various radiological hazard indices. The radionuclide concentrations in the samples varied from 2.123 ± 1.457 Bq/kg to 13.032 ± 3.610 Bq/kg for <sup>238</sup>U, 2.906 ± 1.705 Bq/kg to 17.290 ± 4.158 Bq/kg for <sup>232</sup></p> ... Show More
View Publication
Scopus Crossref
Publication Date
Tue Dec 31 2024
Journal Name
Bulletin Of The Chemical Society Of Ethiopia
Extraction and preconcentration of many metals ions by using CPE technique
...Show More Authors

Cloud point extraction is a simple, safe, and environmentally friendly technique for preparing many different kinds of samples. In this review, we discussed the CPE method and how to apply it to our environmental sample data. We also spoke about the benefits, problems, and likely developments in CPE. This process received a great deal of attention during preconcentration and extraction. It was used as a disconnection and follow-up improvement system before the natural mixtures (nutrients, polybrominated biphenyl ethers, pesticides, polycyclic sweet-smelling hydrocarbons, polychlorinated compounds, and fragrant amines) and inorganic mixtures were examined and many metals like (silver, lead, cadmium, mercury, and so on). We also find

... Show More
View Publication
Scopus (1)
Crossref (1)
Scopus Clarivate Crossref
Publication Date
Thu Jan 01 2015
Journal Name
Journal Of Materials Science And Chemical Engineering
Extraction and Modelling of Oil from Eucalyptus camadulensis by Organic Solvent
...Show More Authors

This work was conducted to study the extraction of eucalyptus oil from natural plants (Eucalyptus camadulensis leaves) by organic solvents. the effects of the main operating parameters were studied; type of solvent (n-hexane and ethanol), time to reach equilibrium, the temperature (45°C to 65°C) for n-hexane and (45°C to 75°C) for ethanol, solvent to solid ratio (5:1 to 8:1 (v/w)), agitation speed (0 to 900 rpm) and the particle size (0.5 to 2.5 cm) of fresh leaves to find the best processing conditions for the achieving maximum oil yield. The concentration of eucalyptus oil in solvent was measured by using UV-spectrophotometer. The results (for n-hexane) showed that the agitation speed of 900 rpm, temperature 65°C with solvent to soli

... Show More
Publication Date
Mon Nov 15 2021
Journal Name
Aip Conference Proceedings
Oil skimming followed by coagulation/flocculation processes for oilfield produced water treatment and zero liquid discharge system application
...Show More Authors

The study focused on the treatment of real oilfield produced water from the East Baghdad field affiliated to the Midland Oil Company (Iraq) using an oil skimming process followed by a coagulation/flocculation process for zero liquid discharge system applications. Belt type oil skimmer was utilized for evaluating the process efficiency with various operating conditions such as temperature (17-40 °C) and time (0.5-2.5 hr.). Polyaluminum chloride (PAC) coagulant and polyacrylamide (PAM) flocculant was used to investigate the performance of the coagulation/flocculation process with PAC dosage (5-90 ppm) and pH (5-10) as operating conditions. In the skimming process, the oil content, COD, turbidity, and TSS decreased with an increase in tempera

... Show More
View Publication
Publication Date
Sun Sep 01 2013
Journal Name
Baghdad Science Journal
A sensitive spectrophotometric determination of tadalafil in pharmaceutical preparations and industrial wastewater samples
...Show More Authors

A simple, accurate, precise, rapid, economical and a high sensitive spectrophotometric method has been developed for the determination of tadalafil in pharmaceutical preparations and industrial wastewater samples, which shows a maximum absorbance at 204 nm in 1:1 ethanol-water. Beer's law was obeyed in the range of 1-7?g/ mL ,with molar absorptivity and Sandell ? s sensitivity of 0.783x105l/mol.cm and 4.97 ng/cm2respectively, relative standard deviation of the method was less than 1.7%, and accuracy (average recovery %) was 100 ± 0. 13. The limits of detection and quantitation are 0.18 and 0.54 µg .ml-1, respectively. The method was successfully applied to the determination of tadalafil in some pharmaceutical formulations

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Wed Feb 01 2023
Journal Name
Baghdad Science Journal
Spectrophotometric Method Combined with HPLC for Bisphenol F Determination in Plastic Bottled Water and Thermal Paper
...Show More Authors

Based on the diazotization-coupling reaction, a new, simple, and sensitive spectrophotometric method for determining of a trace amount of (BPF) is presented in this paper. Diazotized metoclopramide reagent react with bisphenol F produces an orange azo-compound with a maximum absorbance at 461 nm in alkaline solution. The experimental parameters were optimized such as type of alkaline medium, concentration of NaOH, diazotized metoclopramide amount, order additions, reaction time, temperature, and effect of organic solvents to achieve the optimal performance for the proposed method. The absorbance increased linearly with increasing bisphenol F concentration in the range of 0.5-10 μg mL-1 under ideal conditions, with a correlati

... Show More
View Publication Preview PDF
Scopus (1)
Crossref (1)
Scopus Clarivate Crossref
Publication Date
Thu Jun 01 2023
Journal Name
Baghdad Science Journal
Simultaneous Determination of Piroxicam and Codeine Phosphate Hemihydrate in a Pharmaceutical Dosage Form Using Validated HPLC Method
...Show More Authors

An easy, eclectic, precise high-Performance Liquid Chromatographic (HPLC) procedure was evolved and validated to estimate of Piroxicam and Codeine phosphate. Chromatographic demarcation was accomplished on a C18 column [Use BDS Hypersil C18, 5μ, 150 x 4.6 mm] using a mobile phase of methanol: phosphate buffer (60:40, v/v, pH=2.3), the flow rate was 1.1 mL/min, UV detection was at 214 nm. System Suitability tests (SSTs) are typically performed to assess the suitability and effectiveness of the entire chromatography system. The retention time for Piroxicam was found to be 3.95 minutes and 1.46 minutes for Codeine phosphate. The evolved method has been validated through precision, limit of quantitation, specificity,

... Show More
View Publication Preview PDF
Scopus (3)
Crossref (1)
Scopus Crossref