Preferred Language
Articles
/
SBfXoY4BVTCNdQwCGlY5
The Effect of Nano-Hydrated Lime on the Durability of Warm Mix Asphalt
...Show More Authors

Premature failure in asphalt concrete pavement has been the main concern for pavement construction companies and engineers in recent years because of the large rise in traffic volume and loads and the temperature extremes in the summer and winter. The use of modifiers in asphalt concrete mixtures has attracted much attention to increase the performance and lifespan of pavements. As nanotechnology developed, several researchers concentrated on how these materials can help increase pavement serviceability by minimizing rutting and moisture damage. This study evaluates the Hydrated Lime (HL) effect by two methods (wet and dry hydrated lime) on the durability of the warm mix asphalt. The first method, HL, has been supplemented to the asphalt binder with three ratios (0.5%, 1%, and 1.5%) by weight of asphalt (Wet HL). Then, the second method was added via the aggregate weight as a replacement filler using three percentages (1%, 2%, and 3%) (Dry HL). The mechanical qualities, including Marshall Mix design, moisture susceptibility, and permanent deformation, were evaluated through experimental tests. Results showed that the mechanical characteristics and the fineness of the HL particle sizes are positively correlated.            

Crossref
Publication Date
Tue Jun 17 2025
Journal Name
Journal Of Baghdad College Of Dentistry
The effect of light curing tip distance on the curing depth of bulk fill resin based composites
...Show More Authors

Background: This in vitro study measure and compare the effect of light curing tip distance on the depth of cure by measuring vickers microhardness value on two recently launched bulk fill resin based composites Tetric EvoCeram Bulk Fill and Surefil SDR Flow with 4 mm thickness in comparison to Filtek Z250 Universal Restorative with 2 mm thickness. In addition, measure and compare the bottom to top microhardness ratio with different light curing tip distances. Materials and Method: One hundred fifty composite specimens were obtained from two cylindrical plastic molds the first one for bulk fill composites (Tetric EvoCeram Bulk Fill and Surefil SDR Flow) with 4 mm diameter and 4 mm depth, the second one for Filtek Z250 Universal Restorative

... Show More
View Publication Preview PDF
Publication Date
Thu Jun 09 2016
Journal Name
Journal Of The College Of Basic Education
Study the effect of Thymus vulgaris on the weight of Liver and Kidneys in Albino male rats
...Show More Authors

Publication Date
Wed Dec 01 2021
Journal Name
Structures
The effect of ground motion characteristics on the fragility analysis of reinforced concrete frame buildings in Australia
...Show More Authors

View Publication
Crossref (7)
Crossref
Publication Date
Wed Jun 30 2021
Journal Name
Iraqi Geological Journal
The Effect of Weighting Materials on the Rheological Properties of Iraqi and Commercial Bentonite in Direct Emulsion
...Show More Authors

Numerous drilling additives and materials are used continuously because they are necessary to support and give the required properties of the drilling fluid so that to ensure the stability of the borehole. This paper aspires to evaluate the rheological properties of bentonite (montmorillonite) Trefawey as an alternative to using commercial bentonite. Monitoring and evaluating of the rheological and filtration properties were prepared. This exertion aims to focus on the effect of hematite, and barite on the rheological properties of the three aforementioned bentonite types. An improvement in the rheological properties of bentonite (montmorillonite). Trefawey was observed after adding the previous heavy materials. Hematite has by some

... Show More
View Publication
Crossref (1)
Crossref
Publication Date
Sun Jan 13 2019
Journal Name
Iraqi Journal Of Physics
The effect of short range correlation on the inelastic C2 and C4 form factors of 18O nucleus
...Show More Authors

The effect of short range correlations on the inelastic Coulomb form factors for excited +2 states (1.982, 3.919, 5.250 and 8.210MeV) and +4 states (3.553, 7.114, 8.960 and 10.310 MeV) in O18 is analyzed. This effect (which depends on the correlation parameterβ) is inserted into the ground state charge density distribution through the Jastrow type correlation function. The single particle harmonic oscillator wave function is used with an oscillator size parameter .b The parameters β and b are adjusted for each excited state separately so as to reproduce the experimental root mean square charge radius of .18O The nucleusO18 is considered as an inert core of C12 with two protons and four neutrons distributed over 212521211sdp−− activ

... Show More
View Publication Preview PDF
Crossref
Publication Date
Fri Mar 31 2017
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
The Effect of some Variables on the Formulation of Captopril as Tablets Shaymaa Nazar Al – Sammarrai
...Show More Authors

Captopril is an angiotensin converting enzyme inhibitor (ACEI) used to treat hypertension,
congestive heart failure, and myocardial infraction.
The only dosage form available for captopril is the plain tablet in strength of 12.5,25,50 and 100mg
tablet.
This investigation is concerned with factors affecting the formulation of captopril as a plain
tablet dosage form of 50mg. Many trials were made to prepare satisfactory tablets for the drug by
using wet – granulation methods with various additives. It was found that poly vinyl pyrrolidone
(P.V.P.) as binder gave the most satisfactory tablets. At the same time a shorter disintegrantion time
and slower dissolution rate were obtained with the addition of starch

... Show More
View Publication Preview PDF
Crossref
Publication Date
Thu Dec 01 2016
Journal Name
Journal Of Engineering
Analytical and Experimental Investigation for the Effect of Air Injection Angle on the Performance of Airlift Pump
...Show More Authors

The effect of air injection angle on the performance of airlift pump used for water pumping has been studied analytically and experimentally. An airlift pump of dimensions 42mm diameter and 2200 mm length with conventional and modified air injection device was considered. A modification on conventional injection device (normal air-jacket type) was carried out by changing injection angle from 90  (for conventional) to 45  and 22.5  (for modified). Continuity and one-dimensional momentum balance for the flow field with basic principle of two-phase flow and expressions of slip ratio and friction factor as function of flow rates were formulated. The analytical and experimental investigations were carried out f

... Show More
View Publication Preview PDF
Publication Date
Sun Jun 01 2014
Journal Name
Baghdad Science Journal
The Effect of annealing temperature on the optical properties of (Cu2S)100-x( SnS2 )x thin films
...Show More Authors

Thin films of (Cu2S)100-x( SnS2 )x at X=[ 30,40, &50)]% with thickness (0.9±0.03)µm , had been prepared by chemical spray pyrolysis method on glass substrates at 573 K. These films were then annealed under low pressure of(10-2) mbar ,373)423&473)K for one hour . This research includes , studying the the optical properties of (Cu2S)100-x-(SnS2)x at X=[ 30,40, &50)]% .Moreover studying the effect of annealing on their optical properties , in order to fabricate films with high stability and transmittance that can be used in solar cells. The transmittance and absorbance spectra had been recorded in the wavelength range (310 - 1100) nm in order to study the optical properties . It was found that these films had direct optical band

... Show More
View Publication Preview PDF
Crossref
Publication Date
Fri Dec 29 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Effect of Different Magnetic Fields on The Relative Efficiency and The Energy Resolution of Nai(TI) Detectors
...Show More Authors

The effect of different magnetic Jiel ds on the Nal(Tl) scintillation detector of (3"x3") and (1.5"x1.5")   sizes was studies, using the radioactive source Cs-137.

Two type:; of coils (A,B)  were used to produce the magnetic fields. The coil "A" is cylindrical of "9cm" diameter and "9cm" length , and of

2500 turns.

The measurements were taken in two positions ;the first when the crystal inside the coil ,and the second, the PMT inside the coil . The range of the magnetic field was (0.35,0.61,0.84,1.1 1,1.37,1.62,1.87 and

2.12) mT.

The coil "D" consists of two circular and parallel coils of "12 em" distance between them and of "18.5 em" diameter of each other and of "125" turns. rive &

... Show More
View Publication Preview PDF
Publication Date
Sun Jun 12 2011
Journal Name
Baghdad Science Journal
Study The effect of central ion to the dithene complexes on spectral shifting of saturable absorber band
...Show More Authors

In this work dithine complexes prepared from dithiol benzil ligand and central ion to the Ni,Pd,Pt, element the ligand and complexes have been investigated using FTIR spectrophotometer and uv-vis-NIR spectral reigns show higher intensity represents the ?-?* transition in the chromopher cycle .These absorption which appear in visible and near IR spectral regions ,According to the complexes of one group ,the spectral shifting due to the change of central ion has been found to be related to atomic number of central ion .This shifting is increased while decreasing the central ion atom number These complexes have been implemented in Nd+2:YAG cavity because each posses resonant absorption band near Nd+2:YAG, Nd+2:Glass emitting at (106

... Show More
View Publication Preview PDF
Crossref