Background: Hypothyroidism is a clinical syndrome prevalent in women, even those of reproductive age. Ovarian reserve can be defined as the number and quality of follicles in the ovary at any given time. Evaluation of ovarian reserve is recommended for patients at risk of decreased ovarian reserve. Objective: This study aims to evaluate the effect of hypothyroidism on ovarian reserve in Iraqi women by hormonal measurements of serum anti-mullerian hormones AMH, FSH, and LH. Subjects and methods: This case–control study was carried out at the Department of Biochemistry, College of Medicine, University of Baghdad, in collaboration with Endocrinology and Diabetes Clinic, Baghdad Teaching Hospital, and National Center for Teaching Laboratories, Medical City, during the period from November 2021 to March 2022. This study involved 88 women, age range (20-40 years). Fifty-one of them [Group I (GI)] had primary hypothyroidism and were diagnosed by an endocrinologist based on clinical analysis and thyroid function tests, including serum TSH, T4 and T3. Patients with symptoms and signs suggestive of hypothyroidism and elevated TSH with T4 less than the reference level were considered overt hypothyroidism. While patients with elevated TSH with standard T4 and T3 were considered subclinical hypothyroidism 1 , serum thyroid peroxidase antibody (TPOAb) was used to differentiate hypothyroidism patients with Hashimoto`s disease 2 . Thirty-seven of the included women were healthy and served as a control group and referred to group II (GII). Results: The mean (±SD) value of serum AMH of hypothyroidism women was significantly lower than that of controls (p < 0.0001). However, the mean value of AMH did not differ significantly between women who had overt and subclinical hypothyroidism, regular and irregular menstrual cycle, well and poorly controlled thyroid status, and who had positive and negative anti-TPO. The mean (±SD) value of serum LH of hypothyroidism women was significantly higher than that of the control group (p < 0.004), while that of FSH did not differ significantly. Serum TSH levels positively correlated with LH levels (r=0.3, p 0.03). In addition, BMI values were significantly positively correlated with FSH levels (r= 0.3, p 0.04). Conclusions: This study suggested the need for serum measurement of AMH in women suffering from hypothyroidism. Keywords: hypothyroidism, ovarian reserve, AMH.
Mn2O3 was coated onto reduced titania nanotubes by reverse pulse electrodeposition, showing smooth and homogenous deposits without covering the opening of the nanotubes.
Density Functional Theory (DFT) method of the type (B3LYP) and a Gaussian basis set (6-311G) were applied for calculating the vibration frequencies and absorption intensities for normal coordinates (3N-6) at the equilibrium geometry of the Di and Tetra-rings layer (6, 0) zigzag single wall carbon nanotubes (SWCNTs) by using Gaussian-09 program. Both were found to have the same symmetry of D6d point group with C--C bond alternation in all tube rings (for axial bonds, which are the vertical C--Ca bonds in rings layer and for circumferential bonds C—Cc in the outer and mid rings bonds). Assignments of the modes of vibration IR active and inactive vibration frequ
... Show MoreA new, simple and sensitive method was used forevaluation of propranolol withphosphotungstic acidto prove the efficiency, reliability and repeatability of the long distance chasing photometer (NAG-ADF-300-2) using continuous flow injection analysis. The method is based on reaction between propranolol and phosphotungstic acid in an aqueous medium to obtain a yellow precipitate. Optimum parameters was studied to increase the sensitivity for developed method. A linear range for calibration graph was 0.007-13 mmol/L for cell A and 5-15 mmol/L for cell B, and LOD 207.4792 ng/160 µL and 1.2449 µg/160 µL respectively to cell A and cell B with correlation coefficient (r) 0.9988 for cell A, 0.9996 for cell B, RSD% was lower than 1%, (n=8) for the
... Show MoreA series of Schiff base-bearing salicylaldehyde moiety compounds (1-4) had been designed, synthesized, subjected to insilico ADMET prediction, molecular docking, characterization by FT-IR, and CHNS analysis techniques, and finally to their Anti-inflammatory profile using cyclooxygenase fluorescence inhibitor screening assay methods along with standard drugs, celecoxib, and diclofenac. The ADMET studies were used to predict which compounds would be suitable for oral administration, as well as absorption sites, bioavailability, TPSA, and drug likeness. According to the results of ADME data, all of the produced chemicals can be absorbed through the GIT and have passed Lipinski’s rule of five. Through molecular docking with PyRx 0.8, these
... Show MoreNew chelating ligand derived from triazole and its complexes with metal ions Rhodium, Platinum and Gold were synthesized. Through a copper (I)-catalyzed click reaction, the ligand produced 1,3-dipolar cycloaddition between 2,6-bis((prop-2-yn-1-yloxy) methyl) pyridine and 1-azidododecane. All structures of these new compounds were rigorously characterized in the solid state using spectroscopic techniques like: 1HNMR, 13CNMR, Uv-Vis, FTIR, metal and elemental analyses, magnetic susceptibility and conductivity measurements at room temperature, it was found that the ligand acts as a penta and tetradentate chelate through N3O2, N2O2, and the geometry of the new complexes are identified as octahedral for (Rh & Pt) complexes a
... Show Morenovel spectrofluorimetric flow injection analysis (FIA) method was developed for the selective quantification of ascorbic acid via fluorescence quenching of serotonin hydrochloride. The system employs a custom-designed photometric array comprising 16 irradiation sources arranged in a dual-axis matrix—eight aligned horizontally and eight orthogonally, enabling multi-angle excitation and enhanced spectral resolution. Fluorescence signals were captured using a twin-pair solar cell detector, offering high sensitivity and minimal optical interference. The method exhibited a linear calibration range of 0.1–30 limit of detection (LOD) of 0.025 μ μ g/mL with a correlation coefficient (r mol /L, equivalent to 4.403 * 10 4 μ 2 ) of 0.9966, a g
... Show More