Background. The presence of black triangles around the dental implant-supported prosthesis and the failure to construct adequate papillae around them bothers dental implantologists. Peri-implant surgical soft tissue management will improve esthetics, function, and implant survival. Aim. To compare the effects of rolled and nonrolled U-shaped flaps combined with a temporary crown in enhancing the soft tissue around dental implants. Materials and Methods. Forty patients were included in this study; all patients were operated on by the same maxillofacial surgeon at Al-Iraq specialized dental clinics from January 2019 to January 2020. Patients were divided randomly into two groups: group A: at the second stage of implant surgery, a U-shaped flap without rolling was used in conjunction with temporary crown placement; group B: at the second stage of implant surgery, a U-shaped flap with rolling was used in conjunction with temporary crown placement. Then, the temporary crown was fabricated for both groups and kept in place for one month. Two independent maxillofacial surgeons evaluated all patients two weeks after the cementation of the final zirconia crown for the implant soft tissue esthetic score. Results. The highest possible score assigned to the mesial papilla (2 scores) was present in 92.5% of the group A patients and only 77.5% of the group B patients. Moreover, we have found that alveolar bone contour is achieved perfectly (2 scores) in 70% of group A patients but only in 32.5% of group B patients. Conclusion. The U-shaped flap without rolling with a temporary crown is a simple technique. It has good results, especially when there is no severe resorption of the labial bone plate (in canine and premolar areas).
Choosing an appropriate impression material is a challenge for many dentists, yet an essential component to provide an excellent clinical outcome and improve productivity and profit. The purpose of present study was to compare wettability, tear strength and dimensional accuracy of three elastomeric impression materials, with the same consistencies (light-body). Three commercially available light body consistency and regular set 3M ESPE Express polyvinylsiloxane (PVS), 3M ESPE Permadyne polyether (PE), and Identium (ID), impression materials were comparedTear strength test, contact angle test and linear dimensional accuracy were evaluated for three elastic impression material. Among the three experimental groups PE impression materia
... Show MoreTemporomandibular Disorders (TMD) refer to a group of symptoms where pain is the most leading cause to demand a treatment by the patient. Light therapies are of great importance at current times due to its biosafety and non-invasive quality when used for the management of TMD symptoms. This study aimed to evaluate the efficacy of red LED light with low-level LASER in treating TMD patients.
A double-blind randomized clinical study was conducted and included 60 patients along 3 groups (20 for e
Background: Orthodontic mini-implants are increasingly used in orthodontics and the bone density is a very important factor in stabilization and success of mini-implant. The aim of this study was to observe the relationship among maximum bite force (MBF); body mass index (BMI); face width, height and type; and bone density in an attempt to predict bone density from these variables to eliminate the need for CT scan which have a highly hazard on patient. Materials and Methods: Computed tomographic (CT) images were obtained for 70 patients (24 males and 46 females) with age range 18-30 years. The maxillary and mandibular buccal cortical and cancellous bone densities were measured between 2nd premolar and 1st molar at two levels from the alveol
... Show MoreBackground: Postoperative pain is one of the main complications following impacted mandibular third molar (IMTM) surgery. Objectives: The aim of this study was to assess the effect of the local application of bupivacaine on reducing early postoperative pain following IMTM surgery. Material and methods: A prospective, single-blinded, randomized controlled study was conducted on 40 patients who had undergone the surgical removal of an IMTM under local anesthesia. In the study group (n = 20), absorbable gelatin sponge (AGS) soaked in 3 mL of 0.5% plain bupivacaine hydrochloride was locally applied in the post-extraction socket. In the control group (n = 20), AGS soaked in 3 mL of normal saline was used. Pain intensity was assessed using a pa
... Show More